Beretta Kompakt 22 C.S.I. Circulating Pump Grundfos UPS15-50 AO /BC Ref. 59945507
Grundfos UPS15-50 AO /BC circulator pump with P/N 59945507, which moves water through the heating circuit of the boiler. It has 3 speeds (40, 65, and 90 W) and operates at 230 V and 50 Hz. It is confirmed for the Beretta Kompakt 22 C.S.I. It is sold refurbished, tested, and with a 1-year warranty.
- Type of part
- Pumps
- Status
- Refurbished
- internal SKU
- BOM038
- Warranty
- 1 year
Compatible Beretta boilers
Circulating pump. A proven compatibility: Kompakt 22 C.S.I..
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Beretta Kompakt 22 C.S.I. | Beretta | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if it is the part for your boiler
The part reference, model, and equipment revision must be verified against the manufacturer's documentation.
- Look at the motor label. It should say Type UPS15-50 AO /BC, P/N 59945507 and PC 0211BC.
- Compare the data on the label: 230 V, 50 Hz, 2 µF, IP44, class H, TF95, and maximum 3 bar.
- Compare the power and currents of the three speeds: 40 W (0.17 A), 65 W (0.29 A), and 90 W (0.39 A).
- Check the exact model of your boiler on its label. It is confirmed for the Beretta Kompakt 22 C.S.I.
- Compare your pump with the photos: air bleed valve on top, speed selector in the connection box, and power cable.
- If your pump has a Beretta code, or the P/N or designation do not match, send us a photo of the label and the PCB of the boiler from Contact, or call 911 17 77 77.
Symptoms that require diagnosis in the circulation pump
The circulation pump circulates the water in the heating circuit. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The radiators are not heating or are heating little.
Cause: Lack of water circulation in the heating circuit.
Check that the pump is running and that the circuit has pressure. Bleed the air from the radiators.
- 02
The pump sounds or vibrates more than usual.
Cause: Air in the circuit or possible internal wear of the pump.
Bleed the air and try another speed. If the noise persists, there may be internal wear: have it checked by a qualified technician.
- 03
The motor hums but the rotor does not turn.
Cause: Rotor stuck due to scale or sludge, especially after a period of inactivity.
Have it checked by a qualified technician.
- 04
It is leaking water from the pump.
Cause: Joint of the connections in poor condition or leak in the body of the pump.
Check the seals of the connections. If the leak is coming from the body of the pump, it needs to be replaced.
- 05
The boiler locks out due to excessive temperature.
Cause: Lack of water circulation in the boiler.
Check the pump before replacing other parts.
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Technical sheet: Beretta circulator pump
- Uniclima internal SKU
- BOM038
- Brand
- Beretta
- Type of part
- Pumps
- Units in stock
- 2 units
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- Delivery time shown at checkout
- Return
- 14 days
Part data and available documentation
Contrast the label codes, PCB, and revision with the installed part; they are not necessarily equivalent references.
- Reference
- 59945507
- Brand
- Grundfos
- Designation
- UPS15-50 AO /BC
- PC code on the label
- 0211BC
- Voltage and frequency
- 230 V ~ 50 Hz
- Speed I
- 40 W · 0.17 A
- Speed II
- 65 W · 0.29 A
- Speed III
- 90 W · 0.39 A
- Condenser
- 2 µF
- Protection
- IP44
- Insulation class
- H
- Thermal class
- TF95
- Maximum pressure
- 3 bar
- Beretta code on the label
- None
- Assembly
- Motor with pump body, air bleeder at the top, speed selector in the connection box, and power cable, as shown in the photos.
- Do not confuse with 59945504: Another P/N of a Grundfos pump with a similar designation (UP 15-50 AO /BC). It is a different reference: do not consider it equivalent to 59945507.
- Do not confuse with R6094 (BE.6094): Grundfos UPS 15-50 AO circulator from Beretta for Idra, Mynute, and Super Meteo. Its designation does not include “/BC”. We do not consider it equivalent to this pump.
- Do not confuse with R10021792: Beretta code for the circulator of the Kompakt 22 C.S.I. and C.A.I., which is also written as BE10021792 or R20104311. It is not printed on the label of this pump and we do not consider it equivalent to P/N 59945507.