Circulating Pump Biasi Myto Condens Plus 24 Taco Ref. TF0032
The Taco TF0032 circulator pump (P/N 4022.3080.74, type 2PK/53) circulates water through the boiler circuit. It is compatible with the Biasi Myto Condens Plus 24. It operates at 230 V and 3.5–42 W. It is sold refurbished, tested, and with a 1-year warranty.
- Type of part
- Pumps
- Status
- Refurbished
- internal SKU
- BOM079
- Warranty
- 1 year
Compatible Biasi boilers
Circulating pump. A proven compatibility: Myto Condens Plus 24.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Biasi Myto Condens Plus 24 | Manaut | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if it is the part for your boiler
The part reference, model, and equipment revision must be verified against the manufacturer's documentation.
- Check the control board of your boiler, which is a Biasi Myto Condens Plus 24.
- Look for the P/N 4022.3080.74 (or 4022308074), the Taco TF0032 model, and the type 2PK/53 in the body of the pump. In this unit, the label reads "2PK/53 21-…".
- If your pump has a different P/N, for example one that ends in .77, or is a UP15-60 A0, do not order it without consulting: it is not the same code.
- Compare the size, the number of connectors, and the mounting of your pump with the photos.
- If the boiler shows Er 04 or Er 14, before replacing the pump, check the pressure and bleed the system and the pump.
- Any questions? Call 911 17 77 77 or send us a photo of the pump label and the boiler PCB from Contact.
Symptoms that require diagnosis in the circulation pump
The circulation pump circulates the water in the heating circuit. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The boiler shows Er 04.
Cause: Lack of circulation from the pump or insufficient installation pressure.
Check the circuit pressure and bleed the system and the pump.
- 02
The boiler shows Er 14.
Cause: Faulty pump, primary temperature above 105 °C or lack of circulation due to temperature gradient (more than 2 K/s).
Bleed the system and the pump. Check the circulation and the temperature of the primary.
- 03
The pump motor does not vibrate when checking the unlocking.
Cause: Pump blocked.
Perform a reset and repeat the unlocking sequence, up to a maximum of 10 attempts. If the pump does not unlock, call technical service.
Fault codes Biasi that require diagnosis
| Code | Fault | Technical checks |
|---|---|---|
| Er 04 | Lack of circulation from the pump or insufficient installation pressure. | Check the circuit pressure and bleed the system and the pump. |
| Er 14 | Faulty pump or primary temperature above 105 °C. It also indicates lack of circulation due to temperature gradient (more than 2 K/s). | Bleed the system and the pump, and check the primary temperature and circulation. |
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Technical sheet: circulator pump Biasi
- Uniclima internal SKU
- BOM079
- Brand
- Manaut
- Type of part
- Pumps
- Units in stock
- 9 units
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- Delivery time shown at checkout
- Return
- 14 days
Part data and available documentation
Contrast the label codes, PCB, and revision with the installed part; they are not necessarily equivalent references.
- Reference
- TF0032 (also TF 0032 or TF-0032)
- Brand
- Taco
- Spare part number of the body
- 4022.3080.74 (also 4022308074)
- Type
- 2PK/53 (the label on this unit reads "2PK/53 21-…")
- Voltage
- 230 V
- Power
- 3.5–42 W
- Energy efficiency index
- EEI < 0.23 (Part 3)
- Degree of protection
- IP44
- Temperature class
- TF95
- Marked pressure
- 0.6 MPa
- Set
- Complete pump: hydraulic body and motor head with electrical connector
- Status
- Reconditioned and tested
- Warranty
- 1 year
- Do not confuse with 4022.3080.77: Another P/N, different from this pump (4022.3080.74). If the body of yours ends in .77, please consult us before ordering it.
- Do not confuse with 2PK/53-2E-F: Full name of a Taco I Way pump (also written as 1Way or Way). In this unit, the marked type is 2PK/53 followed by other characters, and the model is TF0032. Compare the body before considering it the same.
- Do not confuse with BI1632103: Biasi spare part code for a Taco I Way 2PK/53-2E-F pump. The main codes for this pump are TF0032 and P/N 4022.3080.74. If your boiler requests BI1632103, please consult us.
- Do not confuse with UP15-60 A0: Another pump model, different from the TF0032. Compare the P/N and the type of the body before ordering.
- Do not confuse with 7746900557: Code that is not accredited as equivalent to this pump. Do not consider it valid: compare the P/N and the type of body or consult us.
- Please consult us before purchasing if your boiler is: Manaut Myto Condens Plus 35, Biasi RinNova Cond Plus 25S (M260V.2025 SM), Biasi RinNova Cond Plus 35, Biasi RinNova Cond Plus 35S, Biasi M262.3035 SB/T, Savio Biasi Sile Condensa Serie 6 R.