Saunier Duval Semia Tek F24 Circulating Pump Wilo HB15/4-1 Ref. 0020016835

Saunier Duval Semia Tek F24 Circulating Pump Wilo HB15/4-1 Ref. 0020016835

Wilo HB15/4-1 circulator pump with the reference Saunier Duval 0020016835 and the number Wilo 4516967. It moves the heating water between the boiler and the radiators. Compatible with the Saunier Duval Semia Tek F24. Sold refurbished, tested, and with a 1-year warranty.

Type of part
Pumps
internal SKU
BOM033
Warranty
1 year
VAT included Stock · 7 units
Compatibility

Compatible Saunier Duval boilers

Circulating pump. A proven compatibility: Semia Tek F24.

Proven compatibility

Boiler modelFamilyVerification
Saunier Duval Semia Tek F24Saunier DuvalContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if it is the part for your boiler

The part reference, model, and equipment revision must be verified against the manufacturer's documentation.

  1. Disconnect the power to the boiler before touching the pump. The replacement must be carried out by a qualified technician.
  2. Locate the label of the Wilo motor on your pump. It should indicate Typ HB15/4-1 and No. 4516967.
  3. Look for the Saunier Duval reference (Réf) 0020016835 on the same label. The label on our pump also has the number 4519731.
  4. Compare the electrical data: 65 W, 0.28 A, 230 V, 50 Hz and capacitor of 2 µF.
  5. Look at the label on your boiler. The confirmed model is the Saunier Duval Semia Tek F24.
  6. If your pump has a different reference or your boiler is another model, call us at 911 17 77 77 or send us a photo of the pump label and the boiler's PCB from the Contact section.
Diagnosis and fault codes

Symptoms that require diagnosis in the circulation pump

The circulation pump circulates the water in the heating circuit. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The radiators do not heat up or take a long time to heat, even though the boiler ignites.

    Cause: The pump is not moving the water in the circuit, either there is air or there is a lack of pressure.

    Check that the pump is running, that the circuit has pressure, and that it is properly bled.

  • 02

    The pump makes noise or vibrates.

    Cause: Air in the circuit or internal wear of the pump.

    Bleed the air from the circuit. If the noise persists, the pump may be worn out and it is advisable to replace it.

  • 03

    The pump hums but does not rotate after weeks of being idle.

    Cause: The rotor may be seized due to scale or sludge.

    A technician can try to free it before replacing the pump.

  • 04

    Water is leaking from the pump or its seals.

    Cause: Damaged gasket or shaft seal with leakage.

    Dry the area and locate the exact point of the leak before requesting the spare part.

  • 05

    The boiler locks out or shuts down due to excessive temperature.

    Cause: There may be a lack of water circulation in the circuit.

    Check the pump, the circuit valves, and the filters.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Technical sheet: Saunier Duval circulator pump

Uniclima internal SKU
BOM033
Brand
Saunier Duval
Type of part
Pumps
Units in stock
7 units
Status
Refurbished
Warranty
1 year
Shipping
Delivery time shown at checkout
Return
14 days

Part data and available documentation

Contrast the label codes, PCB, and revision with the installed part; they are not necessarily equivalent references.

Reference
0020016835
Brand of the reference
Saunier Duval
Pump
Wilo HB15/4-1
Wilo No.
4516967 (HB15/4-1 FSL 9 SDPR)
Another number from the label
4519731
Power
65 W
Intensity
0.28 A
Power supply
230 V · 50 Hz
Condenser
2 µF
Protection
IP44 · class F
Nominal pressure
PN6 (6 bar)
Marked
CE · VDE · GS · EMV
Origin
Made in EU
Status
Refurbished and tested, with a 1-year warranty.
Before purchasing
  • Not compatible with Saunier Duval Thema Condens F24: it requires another part, with reference 0020087275.
  • Not valid for Saunier Duval Thema Condens F 24 E: it requires another part, with reference 0020087275.
  • Not valid for Saunier Duval Thematek C 24 E: it uses a different part, the pump group SDS10057.
  • Not valid for Saunier Duval Thematek F 24 E: it requires another part, the pump group SDS10057.
  • Do not confuse with 0020037112: Another Saunier Duval code for heating pump for Semia boilers. We do not consider it equivalent to 0020016835. If this is your pump, please consult us.
  • Do not confuse with 0010030688: Another Saunier Duval code for heating pump for Semia boilers. We do not consider it equivalent to 0020016835. If this is your pump, please consult us.
  • Do not confuse with 0020087275: Pump motor with another code. This is not this pump.
  • Do not confuse with Wilo 4533636: Another Wilo pump, it does not equate to this one. It is proposed as a substitute for number 4516967, but the boiler manufacturer does not always endorse those equivalences.
  • Please consult us before purchasing if your boiler is: Saunier Duval Semia Tek C24, Saunier Duval Semia F24, Saunier Duval Semia C24, Saunier Duval Semia V24.
Frequently Asked Questions

Frequently asked questions about the circulation pump

Is it compatible with my Saunier Duval Semia Tek F24?
Yes. This circulator pump (ref. 0020016835, Wilo HB15/4-1) is compatible with the Saunier Duval Semia Tek F24. Check that the label on your pump indicates HB15/4-1 and the number 4516967. If your boiler is a different model, please contact us at 911 17 77 77.
Where is the code on my pump?
On the Wilo motor label, the silver disk of the pump. You will see "Typ HB15/4-1", "N° 4516967" and "Réf 0020016835". It also has the number 4519731 and the data 65 W, 0.28 A, 230 V and 50 Hz.
Is it compatible with a Semia Tek C24 or with a Semia F24, C24 or V24 without "Tek"?
Contact us before making a purchase. Call us at 911 17 77 77 or send us a photo of your boiler's PCB and the label of your pump from the Contact section.
What is the difference between pumps 0020037112, 0010030688, and 0020087275?
They are different codes. The 0020087275 is a pump motor and is not this part. The 0020037112 and the 0010030688 are other Saunier Duval codes for heating pumps for Semia boilers, and we do not consider them equivalent to the 0020016835. If your pump has one of them, please consult us with a photo of the label.
Can I use the Wilo 4533636 instead?
It is not the same pump. The 4533636 is proposed as a substitute for number 4516967, but the boiler manufacturer does not always endorse these equivalences. This sheet is for the HB15/4-1 number 4516967.
What does it include?
The pump is sold mounted on its hydraulic body, as shown in the photos. If you need cable, connector, or any other accessory, please consult us before purchasing.
Is it sold tested and with a warranty?
Yes. It is a refurbished and tested circulation pump, with a 1-year warranty. The installation must be carried out by a qualified technician.
Entrega calculada por destino Delivery time shown at checkout
1-year warranty reviewed and tested
14-day return uninstalled parts
Technical support we verify your model
Saunier Duval Semia Tek F24 Circulating Pump Wilo HB15/4-1 Ref. 0020016835