Wolf FGB-K-28 circulator pump Grundfos UPM3 15-75 CHB WO Ref. 207216499
Refurbished Wolf Pumps Grundfos

Wolf FGB-K-28 circulator pump Grundfos UPM3 15-75 CHB WO Ref. 207216499

Grundfos UPM3 15-75 CHB WO circulator pump with the Wolf brand on the cover and reference Wolf 207216499. It moves the water in the heating circuit of the boiler and is highly efficient. Compatible with Wolf boilers FGB-K-28, FGB-35, and KGB-K-35. Sold refurbished, tested, and with a 1-year warranty.

Type of part
Pumps
internal SKU
BOM058
Warranty
1 year
VAT included Stock · 7 units
Compatibility

Wolf compatible boilers

Circulating pump. Three confirmed compatibilities: FGB-K-28 and FGB-35.

Proven compatibility

Boiler modelFamilyVerification
Wolf FGB-K-28WolfContrasted
Wolf FGB-35WolfContrasted
Wolf KGB-K-35WolfContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if it is the part for your boiler

The part reference, model, and equipment revision must be verified against the manufacturer's documentation.

  1. First, check that the fault is with the pump: circuit valves open, circuit bled, correct pressure, and pump powered.
  2. Check the motor cover. It should say Grundfos UPM3 15-75 CHB WO, the Wolf brand, and High Efficiency.
  3. Check the reference of your spare part. This is 207216499. If yours has a different code, for example a 7-digit Wolf code like 2074705, please consult us before ordering.
  4. Check the label on your boiler. The model should be Wolf FGB-K-28, FGB-35, or KGB-K-35. If it is another model, please consult us.
  5. Compare the motor and the hydraulic body with the photos. Check that your pump has the same two electrical connectors.
  6. If something does not match or your model is not on the list, send us a photo of the boiler's PCB and the pump's label from the Contact section, or call 911 17 77 77.
Diagnosis and fault codes

Symptoms that require diagnosis in the circulation pump

The circulation pump circulates the water in the heating circuit. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The radiators do not heat up even though the boiler turns on.

    Cause: Closed circuit valves or pump that won't start.

    Check that the circuit valves are open and that the pump starts.

  • 02

    Noise or vibration in the pump.

    Cause: Air in the heating circuit.

    Bleed the air from the radiators and the boiler before changing the pump.

  • 03

    The pump does not start after a long stop.

    Cause: Rotor seized due to scale or sludge.

    Check if the rotor is blocked by scale or sludge.

  • 04

    Water leaks in the pump body.

    Cause: Fault in the seals or in the connection nuts.

    Check the seals and connection nuts.

  • 05

    The boiler locks out due to lack of circulation.

    Cause: Incorrect pressure in the circuit or pump without power supply.

    Check the pressure of the circuit and the power supply of the pump.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Technical sheet: Wolf circulator pump

Uniclima internal SKU
BOM058
Brand
Wolf
Type of part
Pumps
Units in stock
7 units
Status
Refurbished
Warranty
1 year
Shipping
Delivery time shown at checkout
Return
14 days

Part data and available documentation

Contrast the label codes, PCB, and revision with the installed part; they are not necessarily equivalent references.

Reference
207216499 (Wolf reference)
Part
Heating circulation pump
Pump
Grundfos UPM3 15-75 CHB WO
Brand on the lid
Wolf
Efficiency
High Efficiency
Housing marking
PA 6.6
Side label of the motor
J72142
Printed number on the cover
207214210570139333
Electrical connection
Two connectors in the motor
Status
Refurbished and tested, with a 1-year warranty.
Before purchasing
  • Do not confuse with 2074705: Wolf reference for a Grundfos UPM3 15-75 pump. We do not consider it equivalent to 207216499 (CHB WO). If your pump has this code, please consult us before ordering.
  • Do not confuse with J72142: Code on the side label of the motor. It is not the reference for the pump, which is 207216499.
  • Do not confuse with 207214210570139333: Printed number under the Wolf brand on the cover. It is the serial number of the unit, not the spare part reference.
  • Please consult us before purchasing if your boiler is: Wolf FGB-K-24, Wolf FGB-24, Wolf FGB-28, Wolf FGB-K-35.
Frequently Asked Questions

Frequently asked questions about the circulation pump

Is it compatible with my Wolf boiler?
It is compatible with the Wolf FGB-K-28, FGB-35, and KGB-K-35. For other models, such as FGB-24, FGB-28, FGB-K-24, or FGB-K-35, please contact us: send us a photo of your boiler's PCB and the label of your pump from the Contact section, or call 911 17 77 77.
Is it the same as the Wolf 2074705?
We do not consider it equivalent. The 2074705 is another Wolf reference for a Grundfos UPM3 15-75 pump, but this is the 207216499, with the designation CHB WO on the cover. If your pump has the code 2074705, send it to us and we will check it.
What is the reference 207216499?
It is the Wolf reference for this circulator pump. It corresponds to the Grundfos UPM3 15-75 CHB WO, with the Wolf brand on the cover.
Where is the pump code?
On the motor cover, the designation Grundfos UPM3 15-75 CHB WO and the brand Wolf are printed. On the side of the motor, there is another label with a code like J72142. That code is not the spare part reference.
What voltage and connections does it have?
The cover does not indicate the voltage. The motor has two electrical connectors. Send us a photo of your pump and we will compare it before you make a purchase.
Does it include the hydraulic body?
Yes. The motor is mounted on the hydraulic body, as seen in the photos. Compare it with your part before ordering.
Is it sold tested and with a warranty?
Yes. It is sold refurbished, tested, and with a 1-year warranty. The installation must be carried out by a qualified technician.
Entrega calculada por destino Delivery time shown at checkout
1-year warranty reviewed and tested
14-day return uninstalled parts
Technical support we verify your model
Wolf FGB-K-28 circulator pump Grundfos UPM3 15-75 CHB WO Ref. 207216499