Wilo pump INTNFSL12/5 HE-1 · 4522812 for Biasi Midas Eco, Minox Eco, and Myto Condens
Refurbished Biasi Pumps Wilo

Wilo pump INTNFSL12/5 HE-1 · 4522812 for Biasi Midas Eco, Minox Eco, and Myto Condens

It moves the water through the hydraulic circuit of the boiler. It is advisable for a technician to check it before replacing it.

Type of part
Pumps
internal SKU
BCEGISNOX24FF
Warranty
1 year
VAT included Stock · 19 units
Compatibility

Biasi boilers compatible

Circulating pump. Four confirmed compatibilities: Baxi Roca Midas Eco 24 E and Baxi Roca Minox Eco 24 E. There are another 6 models that we are still verifying.

Proven compatibility

Boiler modelFamilyVerification
Manaut / Biasi Manaut Midas Eco 24 EBiasi and Baxi RocaContrasted
Manaut / Biasi Manaut Minox Eco 24 EBiasi and Baxi RocaContrasted
Manaut / Biasi Manaut Myto Condens 24Biasi and Baxi RocaContrasted
Manaut / Biasi Manaut Minox Eco 28 EBiasi and Baxi RocaContrasted

Models pending verification

These models are associated with this reference, but we have not finished verifying them yet, so we do not consider them compatibleIf your boiler is one of them, send us a photo of the part you are going to replace and we will verify it before you purchase.

Manaut / Biasi Biasi Rinnova NOxBiasi and Baxi RocaUnconfirmed
Manaut / Biasi Biasi M160.2025 SMBiasi and Baxi RocaUnconfirmed
Manaut / Biasi Biasi M95.28 CM/BDBiasi and Baxi RocaUnconfirmed
Manaut / Biasi Biasi Activ A Plus (BI1552104)Biasi and Baxi RocaUnconfirmed
Manaut / Biasi Biasi Riva Plus HE (BI1542100)Biasi and Baxi RocaUnconfirmed
Manaut / Biasi Electrolux QuantumBiasi and Baxi RocaUnconfirmed

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if it is the part for your boiler

The part reference, model, and equipment revision must be verified against the manufacturer's documentation.

  1. Look for the designation INTNFSL12/5 HE-1 and the number 4522812 next to "N°" on the pump label. Ours also has 4022.3080.61 and 13W51.
  2. Check the data on the PCB: 230 V · 50 Hz, 77 W and 0.34 A.
  3. Compare 4531269 and the suffix CLF 12 WIT with your pump: Wilo provides them for the NFSL12/5-HE-1 CLF 12 WIT and we are not sure if it is the same. The BI1352100 is another code.
  4. Check if your boiler is Midas Eco 24 E, Minox Eco 24 E or 28 E, or Myto Condens 24. For another model, compare the codes with its parts list.
  5. If they match, call us at 911 17 77 77 with the model of your boiler.
Diagnosis and fault codes

Symptoms that require diagnosis in the circulation pump

The circulation pump circulates the water in the heating circuit. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    Fault E04 on the Biasi Midas Eco 24E/28E

    Cause: The Manaut manual indicates it as "pump circulation fault or insufficient pressure in the system." It is a warning from the boiler, not proof that the pump is faulty: also check the pressure.

  • 02

    The display of the Biasi Midas Eco 24 E shows E04.

    Cause: The boiler detects a lack of circulation from the pump or insufficient pressure in the system. It is a warning from the boiler: it does not prove that the pump is faulty.

    First, check the pressure of the circuit. If it is correct and the warning persists, have a technician check if the pump is circulating the water.

Fault codes Manaut / Biasi that require diagnosis

CodeFaultTechnical checks
E04Lack of circulation from the pump or insufficient pressure in the installation (Biasi Midas Eco 24 E).Check the pressure of the circuit. If it is correct, have a technician check the pump.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Technical sheet: bomba circuladora Manaut / Biasi

Uniclima internal SKU
BCEGISNOX24FF
Brand
Biasi
Type of part
Pumps
Units in stock
19 units
Status
Refurbished
Warranty
1 year
Shipping
Delivery time shown at checkout
Return
14 days

Part data and available documentation

Contrast the label codes, PCB, and revision with the installed part; they are not necessarily equivalent references.

Printed number next to No.
4522812
Voltage
230 V
Frequency
50 Hz
Absorbed power
77 W
Current
0.34 A
Material of the plastic/hydraulic subcomponent
PP-GF30
Alphanumeric code on the label
13W51
Additional printed code
4022.3080.61
Place of manufacture
Manufactured in the EU
Source of additional data
Declared information; auxiliary references and applications without equivalent from the accredited manufacturer.
Inventory — Plastic/Hydraulic Subcomponent
PP-GF30 material
Manufacturer information — What they sell with BI1462109
Only the pump motor ("motor sold separately")
Manufacturer data — INT · NFSL · 12
Integrated asynchronous motor · circulator with air bleeder · 3/4 inch thread · Wilo OEM Catalog 2017 (table NFSL12/6)
Pending applications to verify
Registered application: for your product 10763 ("Circulating Pump Boiler BIASI (INTNFSL12/5 HE-1)"): Rinnova Nox; M160.2025 SM; M95.28 CM/BD. Pending verification with the manufacturer's documentation for the reference and physical variant; this commercial statement does not certify compatibility or interchangeability.
Before purchasing
  • To confirm: Biasi Rinnova Nox, by the name of the pump; the official Biasi parts list lists BI1462109 without naming it.
  • To confirm: Biasi M160.2025 SM, by the name of the pump.
  • To confirm: Biasi M95.28 CM/BD, by the name of the pump.
  • To confirm: Biasi Activ A Plus (BI1552104) —, for the BI1462109; it does not mention the INTNFSL.
  • To confirm: Biasi Riva Plus HE (BI1542100) — for the BI1462109; it does not mention the INTNFSL.
  • To confirm: Electrolux Quantum —, for the BI1462 109; only mention the INTNFSL.
  • Do not confuse: 4531269 — Wilo NFSL12/5-HE-1 CLF 12 WIT, old pump in the official spare parts list of Wilo — Another reference (4531269); we do not know if it is the same pump. Ours has 4522812.
  • Do not confuse: INTKSL 15-5-1 — Wilo pump of 82 W and 0.36 A that lists with BI1462 109 as an alternative item — Another model and another power: ours is INTNFSL12/5 HE-1, of 77 W and 0.34 A.
  • Do not confuse: BI1352100 — "NFSL 12/5 Pump" that is listed for the Minox Eco 24 E (2008.12) — Another code. Only the text NFSL 12/5 matches. 4522812, 4022.3080.61, 13W51, and INTNFSL12/5 HE-1 do not appear.
  • Without confirmation: the 4522812: compare it with the designation INTNFSL12/5 HE-1. The BIs are to be confirmed: the BI1462109 for other pumps (INTKSL 15-5-1, PU 988).
  • Boilers and confirmed codes. Outside:, and (motor) mention the INTNFSL12/5 HE-1; none cite the 4522812. The BI1462 109 is also given for the INTKSL 15-5-1 (82 W) and the PU 988.
Frequently Asked Questions

Frequently asked questions about the circulation pump

Where is the code for this pump and which markings should I compare?
On the pump label. Ours has the designation INTNFSL12/5 HE-1, the number 4522812 next to "N°", the code 4022.3080.61, and the alphanumeric 13W51, as well as 230 V · 50 Hz, 77 W, and 0.34 A. Compare the designation and 4522812: the short number is not enough.
Is it compatible with my Biasi Midas Eco 24 E, Minox Eco 24 E or 28 E, or Myto Condens 24?
Yes. Confirmation registered: this pump for the Midas Eco 24 E, Minox Eco 24 E, Minox Eco 28 E, and Myto Condens 24. Also the list for Biasi Midas, Myto Condens, and Minox Eco, without specifying the version.
What are the codes BI1462109 and BI1462103?
Spare part codes. The BI1462 109 appears in the water group of the official breakdowns of the Manaut Midas Eco and the Biasi RinNOVA NOx, without naming the part. It is linked with the INTNFSL12/5 HE-1, the BI1462103. To be confirmed: the BI1462109 for other Wilo pumps.
Is it compatible with a Biasi boiler, like the Rinnova Nox, or with an Electrolux Quantum?
Not confirmed for any. Rinnova Nox: the official breakdown from Biasi lists the BI1462 109 without mentioning the pump. M160.2025 SM and M95.28 CM/BD: only. Activ A Plus and Riva Plus HE: . Quantum: . Send us a photo of your label and the boiler's PCB from Contact.
What is the difference between the NFSL12/5-HE-1 CLF 12 WIT, the INTKSL 15-5-1, or the "pump NFSL 12/5" BI1352100?
They are different codes from our label. Wilo provides the NFSL12/5-HE-1 CLF 12 WIT with reference 4531269 as an old pump; we do not know if it is the same. The INTKSL 15-5-1 listed with the BI1462 109 is 82 W and 0.36 A. It lists "BOMBA NFSL 12/5 – BI1352100" for the Minox Eco 24 E: only the text NFSL 12/5 matches.
What does INTNFSL12/5 HE-1 mean in the Wilo designation?
According to the Wilo OEM catalog (2017): INT, integrated asynchronous motor; NFSL, circulator with air bleeder; 12, 3/4 thread. In the NFSL12/6 series: explain the designation, do not confirm this pump.
Who should install it?
A qualified technician. The pump operates at 230 V and is part of the water circuit of the boiler: replace it with the boiler powered off.
Entrega calculada por destino Delivery time shown at checkout
1-year warranty reviewed and tested
14-day return uninstalled parts
Technical support we verify your model
Wilo pump INTNFSL12/5 HE-1 · 4522812 for Biasi Midas Eco, Minox Eco, and Myto Condens