Vaillant Turboblock VCM ES 182 Circulating Pump Ref. 161111
Circulating pump for Vaillant Turboblock VCM/VC boilers series 182-282. It circulates the water of the heating circuit between the boiler and the radiators. According to the label, it is model VP5, 230V~50Hz, 95W, with reference Vaillant 161111. Replacement requires first confirming the fault of the part through technical diagnosis, even when circulation fails, it makes noise, or it leaks water.
- Type of part
- Pumps
- Status
- Refurbished
- Catalogue reference
- 161111
- Warranty
- 1 year
Vaillant boilers compatible with reference 161111
Circulating pump with reference 161111. 37 verified compatibilities: TURBOBLOCK VMW 182/1 E and TURBOBLOCK VMW 242/1 E.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Vaillant TURBOBLOCK VMW 182/1 E | Vaillant Turboblock (VCM/VMW 182-282 E and 180-280 X series /1) | Contrasted |
| Vaillant TURBOBLOCK VMW 242/1 E | Vaillant Turboblock (VCM/VMW 182-282 E and 180-280 X series /1) | Contrasted |
| Vaillant TURBOBLOCK VMW 282/1 E | Vaillant Turboblock (VCM/VMW 182-282 E and 180-280 X series /1) | Contrasted |
| Vaillant TURBOBLOCK VM 242/1 E | Vaillant Turboblock (VCM/VMW 182-282 E and 180-280 X series /1) | Contrasted |
| Vaillant TURBOBLOCK VM 282/1 E | Vaillant Turboblock (VCM/VMW 182-282 E and 180-280 X series /1) | Contrasted |
| Vaillant TURBOBLOCK VMW 180/1 X | Vaillant Turboblock (VCM/VMW 182-282 E and 180-280 X series /1) | Contrasted |
| Vaillant TURBOBLOCK VMW 240/1 X | Vaillant Turboblock (VCM/VMW 182-282 E and 180-280 X series /1) | Contrasted |
| Vaillant TURBOBLOCK VMW 280/1 X | Vaillant Turboblock (VCM/VMW 182-282 E and 180-280 X series /1) | Contrasted |
| Vaillant TURBOBLOCK VM 180/1 X | Vaillant Turboblock (VCM/VMW 182-282 E and 180-280 X series /1) | Contrasted |
| Vaillant TURBOBLOCK VM 240/1 X | Vaillant Turboblock (VCM/VMW 182-282 E and 180-280 X series /1) | Contrasted |
| Vaillant TURBOBLOCK VM 280/1 X | Vaillant Turboblock (VCM/VMW 182-282 E and 180-280 X series /1) | Contrasted |
| Vaillant VCM 182/1 E | Vaillant Turboblock (VCM/VMW 182-282 E and 180-280 X series /1) | Contrasted |
| Vaillant VCM 242/1 E | Vaillant Turboblock (VCM/VMW 182-282 E and 180-280 X series /1) | Contrasted |
| Vaillant VCM 282/1 E | Vaillant Turboblock (VCM/VMW 182-282 E and 180-280 X series /1) | Contrasted |
| Vaillant VCM 180/1 | Vaillant Turboblock (VCM/VMW 182-282 E and 180-280 X series /1) | Contrasted |
| Vaillant VCM 240/1 | Vaillant Turboblock (VCM/VMW 182-282 E and 180-280 X series /1) | Contrasted |
| Vaillant VCM 260/1 | Vaillant Turboblock (VCM/VMW 182-282 E and 180-280 X series /1) | Contrasted |
| Vaillant VC 240/1 | Vaillant Turboblock (VCM/VMW 182-282 E and 180-280 X series /1) | Contrasted |
| Vaillant VC 242/1 E | Vaillant Turboblock (VCM/VMW 182-282 E and 180-280 X series /1) | Contrasted |
| Vaillant ATMOBLOCK VMW 182 E | Vaillant Atmoblock (VCM/VMW 182-282 E and 180-280 X base series) | Contrasted |
| Vaillant ATMOBLOCK VMW 242 E | Vaillant Atmoblock (VCM/VMW 182-282 E and 180-280 X base series) | Contrasted |
| Vaillant ATMOBLOCK VMW 282 E | Vaillant Atmoblock (VCM/VMW 182-282 E and 180-280 X base series) | Contrasted |
| Vaillant ATMOBLOCK VM 242 E | Vaillant Atmoblock (VCM/VMW 182-282 E and 180-280 X base series) | Contrasted |
| Vaillant ATMOBLOCK VM 282 E | Vaillant Atmoblock (VCM/VMW 182-282 E and 180-280 X base series) | Contrasted |
| Vaillant ATMOBLOCK VMW 180 X | Vaillant Atmoblock (VCM/VMW 182-282 E and 180-280 X base series) | Contrasted |
| Vaillant ATMOBLOCK VMW 240 X | Vaillant Atmoblock (VCM/VMW 182-282 E and 180-280 X base series) | Contrasted |
| Vaillant ATMOBLOCK VMW 280 X | Vaillant Atmoblock (VCM/VMW 182-282 E and 180-280 X base series) | Contrasted |
| Vaillant ATMOBLOCK VM 180 X | Vaillant Atmoblock (VCM/VMW 182-282 E and 180-280 X base series) | Contrasted |
| Vaillant ATMOBLOCK VM 280 X | Vaillant Atmoblock (VCM/VMW 182-282 E and 180-280 X base series) | Contrasted |
| Vaillant VCM 182 E | Vaillant Atmoblock (VCM/VMW 182-282 E and 180-280 X base series) | Contrasted |
| Vaillant VCM 242 E | Vaillant Atmoblock (VCM/VMW 182-282 E and 180-280 X base series) | Contrasted |
| Vaillant VCM 282 E | Vaillant Atmoblock (VCM/VMW 182-282 E and 180-280 X base series) | Contrasted |
| Vaillant VCM 180 | Vaillant Atmoblock (VCM/VMW 182-282 E and 180-280 X base series) | Contrasted |
| Vaillant VCM 240 | Vaillant Atmoblock (VCM/VMW 182-282 E and 180-280 X base series) | Contrasted |
| Vaillant VCM 260 | Vaillant Atmoblock (VCM/VMW 182-282 E and 180-280 X base series) | Contrasted |
| Vaillant VC 240 | Vaillant Atmoblock (VCM/VMW 182-282 E and 180-280 X base series) | Contrasted |
| Vaillant VC 242 E | Vaillant Atmoblock (VCM/VMW 182-282 E and 180-280 X base series) | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if the reference 161111 is the part for your boiler
The part reference, model, and equipment revision must be verified against the manufacturer's documentation.
- Find the reference printed on the installed part and check whether it matches the catalogue reference 161111. If it is not visible, do not identify the part from its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms that require diagnosis in the circulator pump 161111
The circulation pump circulates the water in the heating circuit. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The heating is not heating or is heating little, although the boiler ignites without any problem.
Cause: The water is not being pumped, so the heat is not reaching the radiators.
Touch the pump while it's running: if you don't feel any vibration or heat, it may be stopped.
- 02
There is noticeable noise or vibration in the pump during operation.
Cause: There may be air in the circuit or a bearing worn out from use.
Bleed the air from the system and the pump before considering replacing it.
- 03
Water is leaking from the pump body or from the bleeding area.
Cause: The shaft seal or the bleed valve gasket may have lost tightness over time.
Tighten the bleed screw; if the leak persists, then it's time to replace the pump.
- 04
The pump gets stuck at the beginning of the heating season, after months of not being used.
Cause: Stagnant water leaves sediments that block the impeller.
Before replacing it, try to manually unlock the shaft with a flat screwdriver.
Vaillant fault codes that require diagnosis
| Code | Fault | Technical checks |
|---|---|---|
| F.23 | Safety shutdown: temperature difference too high. | If the circulating pump (Ref. 161111) is blocked or underperforming, the flow rate drops and the boiler detects an excessive flow/return temperature difference; check bleeding, ensure the pump rotates and its consumption/flow rate (the ΔT normalizes once circulation is restored). |
| F.24 | Safety shutdown: temperature increase too fast. | A seized or underpowered circulating pump (Ref. 161111) does not move water, and the flow temperature rises too quickly; check the pump start-up, rotor rotation, and ensure there is circulation/hot return after energizing it. |
| F.75 | Pump fault/lack of water: when the pump starts, a sufficient pressure increase is not detected. | If the circulating pump (Ref. 161111) does not start or does not generate flow, the sensor does not detect the expected pressure increase; check that the pump rotates and that the sensor registers a pressure jump when energized (if not, pump blocked/faulty). |
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Data sheet for the Vaillant 161111 circulation pump.
- Catalogue reference
- 161111
- Uniclima internal SKU
- BCTVCM182
- Brand
- Vaillant
- Type of part
- Pumps
- Units in stock
- 3 units
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- Delivery time shown at checkout
- Return
- 14 days
Part data and available documentation
Contrast the label codes, PCB, and revision with the installed part; they are not necessarily equivalent references.
- model
- VP5
- Max pressure
- Max 3 bar
- protection
- IP42, TF95
- Insulation class
- Class H
- voltage
- 230V ~50Hz
- current
- 0.40A
- power
- 95W
- capacitor
- 2.5µF
- Vaillant reference
- 161111
Manuals and technical documentation
Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.
- Vaillant TURBOBLOCK VMW 282/1 E Manual (PDF) Document © Vaillant, provided as a technical reference.