Vaillant Turboblock VCM ES 182 Circulating Pump Ref. 161111
RefurbishedVaillantPumpsGrundfos

Vaillant Turboblock VCM ES 182 Circulating Pump Ref. 161111

Stock · 3 units

Circulating pump for Vaillant Turboblock VCM/VC series 182-282 boilers. It circulates the water in the heating circuit between the boiler and the radiators. According to the label, it is model VP5, 230V~50Hz, 95W, with Vaillant reference 161111. It is replaced when circulation fails, it makes noise, or it leaks water.

VAT included

Compatibility

Vaillant boilers compatible with reference 161111

Circulating pump with reference 161111. 37 verified compatibilities: TURBOBLOCK VMW 182/1 E and TURBOBLOCK VMW 242/1 E.

Proven compatibility

Boiler modelFamilyVerification
Vaillant TURBOBLOCK VMW 182/1 EVaillant Turboblock (VCM/VMW 182-282 E and 180-280 X series /1)Contrasted
Vaillant TURBOBLOCK VMW 242/1 EVaillant Turboblock (VCM/VMW 182-282 E and 180-280 X series /1)Contrasted
Vaillant TURBOBLOCK VMW 282/1 EVaillant Turboblock (VCM/VMW 182-282 E and 180-280 X series /1)Contrasted
Vaillant TURBOBLOCK VM 242/1 EVaillant Turboblock (VCM/VMW 182-282 E and 180-280 X series /1)Contrasted
Vaillant TURBOBLOCK VM 282/1 EVaillant Turboblock (VCM/VMW 182-282 E and 180-280 X series /1)Contrasted
Vaillant TURBOBLOCK VMW 180/1 XVaillant Turboblock (VCM/VMW 182-282 E and 180-280 X series /1)Contrasted
Vaillant TURBOBLOCK VMW 240/1 XVaillant Turboblock (VCM/VMW 182-282 E and 180-280 X series /1)Contrasted
Vaillant TURBOBLOCK VMW 280/1 XVaillant Turboblock (VCM/VMW 182-282 E and 180-280 X series /1)Contrasted
Vaillant TURBOBLOCK VM 180/1 XVaillant Turboblock (VCM/VMW 182-282 E and 180-280 X series /1)Contrasted
Vaillant TURBOBLOCK VM 240/1 XVaillant Turboblock (VCM/VMW 182-282 E and 180-280 X series /1)Contrasted
Vaillant TURBOBLOCK VM 280/1 XVaillant Turboblock (VCM/VMW 182-282 E and 180-280 X series /1)Contrasted
Vaillant VCM 182/1 EVaillant Turboblock (VCM/VMW 182-282 E and 180-280 X series /1)Contrasted
Vaillant VCM 242/1 EVaillant Turboblock (VCM/VMW 182-282 E and 180-280 X series /1)Contrasted
Vaillant VCM 282/1 EVaillant Turboblock (VCM/VMW 182-282 E and 180-280 X series /1)Contrasted
Vaillant VCM 180/1Vaillant Turboblock (VCM/VMW 182-282 E and 180-280 X series /1)Contrasted
Vaillant VCM 240/1Vaillant Turboblock (VCM/VMW 182-282 E and 180-280 X series /1)Contrasted
Vaillant VCM 260/1Vaillant Turboblock (VCM/VMW 182-282 E and 180-280 X series /1)Contrasted
Vaillant VC 240/1Vaillant Turboblock (VCM/VMW 182-282 E and 180-280 X series /1)Contrasted
Vaillant VC 242/1 EVaillant Turboblock (VCM/VMW 182-282 E and 180-280 X series /1)Contrasted
Vaillant ATMOBLOCK VMW 182 EVaillant Atmoblock (VCM/VMW 182-282 E and 180-280 X base series)Contrasted
Vaillant ATMOBLOCK VMW 242 EVaillant Atmoblock (VCM/VMW 182-282 E and 180-280 X base series)Contrasted
Vaillant ATMOBLOCK VMW 282 EVaillant Atmoblock (VCM/VMW 182-282 E and 180-280 X base series)Contrasted
Vaillant ATMOBLOCK VM 242 EVaillant Atmoblock (VCM/VMW 182-282 E and 180-280 X base series)Contrasted
Vaillant ATMOBLOCK VM 282 EVaillant Atmoblock (VCM/VMW 182-282 E and 180-280 X base series)Contrasted
Vaillant ATMOBLOCK VMW 180 XVaillant Atmoblock (VCM/VMW 182-282 E and 180-280 X base series)Contrasted
Vaillant ATMOBLOCK VMW 240 XVaillant Atmoblock (VCM/VMW 182-282 E and 180-280 X base series)Contrasted
Vaillant ATMOBLOCK VMW 280 XVaillant Atmoblock (VCM/VMW 182-282 E and 180-280 X base series)Contrasted
Vaillant ATMOBLOCK VM 180 XVaillant Atmoblock (VCM/VMW 182-282 E and 180-280 X base series)Contrasted
Vaillant ATMOBLOCK VM 280 XVaillant Atmoblock (VCM/VMW 182-282 E and 180-280 X base series)Contrasted
Vaillant VCM 182 EVaillant Atmoblock (VCM/VMW 182-282 E and 180-280 X base series)Contrasted
Vaillant VCM 242 EVaillant Atmoblock (VCM/VMW 182-282 E and 180-280 X base series)Contrasted
Vaillant VCM 282 EVaillant Atmoblock (VCM/VMW 182-282 E and 180-280 X base series)Contrasted
Vaillant VCM 180Vaillant Atmoblock (VCM/VMW 182-282 E and 180-280 X base series)Contrasted
Vaillant VCM 240Vaillant Atmoblock (VCM/VMW 182-282 E and 180-280 X base series)Contrasted
Vaillant VCM 260Vaillant Atmoblock (VCM/VMW 182-282 E and 180-280 X base series)Contrasted
Vaillant VC 240Vaillant Atmoblock (VCM/VMW 182-282 E and 180-280 X base series)Contrasted
Vaillant VC 242 EVaillant Atmoblock (VCM/VMW 182-282 E and 180-280 X base series)Contrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if the reference 161111 is the part for your boiler

What determines it is not the boiler model, but the reference printed on the part you already have installed.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference 161111. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms and faults that the circulator pump 161111 resolves.

The circulation pump circulates the water in the heating circuit. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The heating is not heating or is heating little, although the boiler ignites without any problem.

    Cause: The water is not being pumped, so the heat is not reaching the radiators.

    Touch the pump while it's running: if you don't feel any vibration or heat, it may be stopped.

  • 02

    There is noticeable noise or vibration in the pump during operation.

    Cause: There may be air in the circuit or a bearing worn out from use.

    Bleed the air from the system and the pump before considering replacing it.

  • 03

    Water is leaking from the pump body or from the bleeding area.

    Cause: The shaft seal or the bleed valve gasket may have lost tightness over time.

    Tighten the bleed screw; if the leak persists, then it's time to replace the pump.

  • 04

    The pump gets stuck at the beginning of the heating season, after months of not being used.

    Cause: Stagnant water leaves sediments that block the impeller.

    Before replacing it, try to manually unlock the shaft with a flat screwdriver.

Fault codes from Vaillant that this part resolves.

CodeFaultDiagnosis and solution
F.23Safety shutdown: temperature difference too high.If the circulating pump (Ref. 161111) is blocked or underperforming, the flow rate drops and the boiler detects an excessive flow/return temperature difference; check bleeding, ensure the pump rotates and its consumption/flow rate (the ΔT normalizes once circulation is restored).
F.24Safety shutdown: temperature increase too fast.A seized or underpowered circulating pump (Ref. 161111) does not move water, and the flow temperature rises too quickly; check the pump start-up, rotor rotation, and ensure there is circulation/hot return after energizing it.
F.75Pump fault/lack of water: when the pump starts, a sufficient pressure increase is not detected.If the circulating pump (Ref. 161111) does not start or does not generate flow, the sensor does not detect the expected pressure increase; check that the pump rotates and that the sensor registers a pressure jump when energized (if not, pump blocked/faulty).

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Data sheet for the Vaillant 161111 circulation pump.

Catalogue reference
161111
Brand
Vaillant
Type of part
Pumps
Units in stock
3 units
Status
Refurbished
Warranty
1 year
Shipping
Delivery time shown at checkout
Return
14 days

Data read on the part and in the manufacturer's documentation

What we have not been able to verify does not appear here.

model
VP5
Max pressure
Max 3 bar
protection
IP42, TF95
Insulation class
Class H
voltage
230V ~50Hz
current
0.40A
power
95W
capacitor
2.5µF
Vaillant reference
161111
Documentation

Manuals and technical documentation

Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.

Frequently Asked Questions

Frequently asked questions about the circulator pump 161111

What reference should I request for the pump of the Vaillant Turboblock VCM ES 182?
You must request the reference BCTVCM182, which corresponds to the Vaillant 161111 circulation pump.
What is the maximum pressure that the Vaillant 161111 circulation pump can withstand?
The pump supports a maximum pressure of 3 bar, according to the label.
What electrical supply does the Vaillant 161111 circulation pump require?
It requires a power supply of 230V~50Hz and 95W, according to the label.
Which models are compatible with the Vaillant 161111 circulation pump?
The pump is compatible with 37 models from the Vaillant Turboblock and Atmoblock ranges, including TURBOBLOCK VMW 182/1 E and VCM 182/1 E.
What are the documented fault codes for the Vaillant 161111 circulation pump?
The documented fault codes are F.23, F.24, and F.75.

Spare parts related to Vaillant Vaillant Turboblock (VCM/VMW 182-282 E and 180-280 X series /1)

Entrega calculada por destinoDelivery time shown at checkout
1-year warrantyreviewed and tested
14-day returnuninstalled parts
Technical supportwe verify your model
Vaillant Turboblock VCM ES 182 Circulating Pump Ref. 161111