Watts 3 Bar Safety Valve Sime Murelle EV - Ref. 6040211
RefurbishedSimeSafety valvesWatts

Watts 3 Bar Safety Valve Sime Murelle EV - Ref. 6040211

The Watts 3 Bar Safety Valve Sime Murelle EV - Ref. 6040211 is a component designed to release water when the circuit pressure exceeds 3 bar. If it fails, you will notice that it drips continuously or, on the contrary, does not discharge when it should. This valve is compatible with boilers from the Murelle EV, Metropolis DGT, and Format DGT ranges, among others. A technician must confirm through diagnosis whether it needs to be replaced if you observe leaks or malfunctioning in the system pressure.

Type of part
Safety valves
Catalogue reference
6040211
Warranty
1 year
VAT includedStock · 2 units
Compatibility

Sime boilers compatible with reference 6040211

Safety valve with reference 6040211. 28 verified compatibilities: Murelle EV 20 BFT and Murelle EV 25 BF.

Proven compatibility

Boiler modelFamilyVerification
Sime Murelle EV 20 BFTMurelle EV / Murelle EV HEContrasted
Sime Murelle EV 25 BFMurelle EV / Murelle EV HEContrasted
Sime Murelle EV 25 BFTMurelle EV / Murelle EV HEContrasted
Sime Murelle EV 30 BFMurelle EV / Murelle EV HEContrasted
Sime Murelle EV 35 BFMurelle EV / Murelle EV HEContrasted
Sime Murelle EV HE 12 TMurelle EV / Murelle EV HEContrasted
Sime Murelle EV HE 20 TMurelle EV / Murelle EV HEContrasted
Sime Murelle EV HE 25 TMurelle EV / Murelle EV HEContrasted
Sime Murelle EV HE 30 TMurelle EV / Murelle EV HEContrasted
Sime Murelle EV HE 35 TMurelle EV / Murelle EV HEContrasted
Sime Metropolis DGT 25 BFMetropolis DGTContrasted
Sime Metropolis DGT 25 OFMetropolis DGTContrasted
Sime Metropolis DGT 30 BFMetropolis DGTContrasted
Sime Metropolis Digit 25C ClimaplusMetropolis DGTContrasted
Sime Metropolis Digit 25V ClimaplusMetropolis DGTContrasted
Sime Metropolis Digit 30V ClimaplusMetropolis DGTContrasted
Sime Format DGT 25 BFFormat DGT / Format DGT HEContrasted
Sime Format DGT 25 OFFormat DGT / Format DGT HEContrasted
Sime Format DGT 30 BFFormat DGT / Format DGT HEContrasted
Sime Format DGT HE 12 TFormat DGT / Format DGT HEContrasted
Sime Format DGT HE 20 TFormat DGT / Format DGT HEContrasted
Sime Format DGT HE 25Format DGT / Format DGT HEContrasted
Sime Format DGT HE 30Format DGT / Format DGT HEContrasted
Sime Format DGT HE 35Format DGT / Format DGT HEContrasted
Sime Brava DGT HE 12 TBrava DGT HEContrasted
Sime Brava DGT HE 25Brava DGT HEContrasted
Sime Brava DGT HE 30Brava DGT HEContrasted
Sime Brava DGT HE 35Brava DGT HEContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. 6040211 is the part for your boiler

The part reference, model, and equipment revision must be verified against the manufacturer's documentation.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference 6040211. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms that require diagnosis in the safety valve 6040211

The safety valve releases pressure when the circuit exceeds its setting. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    Water continuously drips from the safety valve, even when the boiler is off.

    Cause: The valve seat does not seal and allows water to escape even without pressure spikes.

    With the system cold, check the pressure on the gauge: if it is within the normal range and it continues to drip, the fault is in the seal, not the pressure.

  • 02

    The heating circuit loses pressure and needs to be refilled from time to time.

    Cause: A slow and steady leak through the valve can go unnoticed and result in that progressive loss.

    Also check the expansion vessel and bleed the radiators before assuming it's the valve.

  • 03

    The valve leaks water just when the boiler heats strongly.

    Cause: If the circuit exceeds the set pressure of 3 bar at that moment, the valve acts as it should to protect the installation.

    Check the cold fill pressure and the condition of the expansion vessel before replacing the valve: if it is discharged, the pressure rises too much when heating.

  • 04

    After bleeding the valve, it continues to drip and doesn't fully close.

    Cause: Lime deposits on the seat can prevent the valve from resealing after bleeding.

    Bleed several times in a row with force; if the jet cleans the seat and then closes, it wasn't necessary to replace it.

Sime fault codes that require diagnosis

CodeFaultTechnical checks
AL 03High water pressureThe boiler detects that the water pressure exceeds 2.8 bar. This can cause inefficient operation or damage to the system, so the boiler stops to protect itself. If the safety valve is not functioning properly, the pressure may continue to rise, which could lead to a more serious fault.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Data sheet for the safety valve Sime 6040211

Catalogue reference
6040211
Uniclima internal SKU
VLSGSM-EV
Brand
Sime
Type of part
Safety valves
Units in stock
2 units
Status
Refurbished
Warranty
1 year
Shipping
Delivery time shown at checkout
Return
14 days

Part data and available documentation

Contrast the label codes, PCB, and revision with the installed part; they are not necessarily equivalent references.

Setpoint
3 bar
Manufacturer
Watts
Frequently Asked Questions

Frequently asked questions about the safety valve 6040211

Is this Watts safety valve suitable for a Sime Metropolis DGT 25 BF?
Yes, Metropolis DGT 25 BF is on the list of compatible boilers along with Murelle EV, Brava DGT HE, and Format DGT.
Who manufactures the safety valve for the Sime Murelle EV?
Watts, according to the embossed logo and the circular seal with the word 'eco' on the body.
What is the pressure setting of the gas valve on the Sime Murelle EV?
3 bar, readable on the actual piece.
Does this Watts valve work for the Sime Ecomfort Plus?
Yes, Ecomfort Plus is on the list of boilers compatible with Ref. 6040211.
Is it the same gas valve for the Sime Brava DGT HE and the Murelle EV?
Yes, both are on the list of boilers compatible with this Watts valve.
What is the reference for this Watts safety valve?
VLSGSM-EV is Uniclima’s internal SKU for locating this listing. To confirm compatibility, check the manufacturer’s reference and the exact appliance model.
Entrega calculada por destinoDelivery time shown at checkout
1-year warrantyreviewed and tested
14-day returnuninstalled parts
Technical supportwe verify your model
Watts 3 Bar Safety Valve Sime Murelle EV - Ref. 6040211