Watts 3 Bar Safety Valve Sime Murelle EV - Ref. 6040211
The Watts 3 Bar Safety Valve Sime Murelle EV - Ref. 6040211 is a component designed to release water when the circuit pressure exceeds 3 bar. If it fails, you will notice that it drips continuously or, on the contrary, does not discharge when it should. This valve is compatible with boilers from the Murelle EV, Metropolis DGT, and Format DGT ranges, among others. It is recommended to replace it if you observe leaks or malfunctioning in the system pressure.
Sime boilers compatible with reference 6040211
Safety valve with reference 6040211. 28 verified compatibilities: Murelle EV 20 BFT and Murelle EV 25 BF.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Sime Murelle EV 20 BFT | Murelle EV / Murelle EV HE | Contrasted |
| Sime Murelle EV 25 BF | Murelle EV / Murelle EV HE | Contrasted |
| Sime Murelle EV 25 BFT | Murelle EV / Murelle EV HE | Contrasted |
| Sime Murelle EV 30 BF | Murelle EV / Murelle EV HE | Contrasted |
| Sime Murelle EV 35 BF | Murelle EV / Murelle EV HE | Contrasted |
| Sime Murelle EV HE 12 T | Murelle EV / Murelle EV HE | Contrasted |
| Sime Murelle EV HE 20 T | Murelle EV / Murelle EV HE | Contrasted |
| Sime Murelle EV HE 25 T | Murelle EV / Murelle EV HE | Contrasted |
| Sime Murelle EV HE 30 T | Murelle EV / Murelle EV HE | Contrasted |
| Sime Murelle EV HE 35 T | Murelle EV / Murelle EV HE | Contrasted |
| Sime Metropolis DGT 25 BF | Metropolis DGT | Contrasted |
| Sime Metropolis DGT 25 OF | Metropolis DGT | Contrasted |
| Sime Metropolis DGT 30 BF | Metropolis DGT | Contrasted |
| Sime Metropolis Digit 25C Climaplus | Metropolis DGT | Contrasted |
| Sime Metropolis Digit 25V Climaplus | Metropolis DGT | Contrasted |
| Sime Metropolis Digit 30V Climaplus | Metropolis DGT | Contrasted |
| Sime Format DGT 25 BF | Format DGT / Format DGT HE | Contrasted |
| Sime Format DGT 25 OF | Format DGT / Format DGT HE | Contrasted |
| Sime Format DGT 30 BF | Format DGT / Format DGT HE | Contrasted |
| Sime Format DGT HE 12 T | Format DGT / Format DGT HE | Contrasted |
| Sime Format DGT HE 20 T | Format DGT / Format DGT HE | Contrasted |
| Sime Format DGT HE 25 | Format DGT / Format DGT HE | Contrasted |
| Sime Format DGT HE 30 | Format DGT / Format DGT HE | Contrasted |
| Sime Format DGT HE 35 | Format DGT / Format DGT HE | Contrasted |
| Sime Brava DGT HE 12 T | Brava DGT HE | Contrasted |
| Sime Brava DGT HE 25 | Brava DGT HE | Contrasted |
| Sime Brava DGT HE 30 | Brava DGT HE | Contrasted |
| Sime Brava DGT HE 35 | Brava DGT HE | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if ref. 6040211 is the part for your boiler
What determines it is not the boiler model, but the reference printed on the part you already have installed.
- Find the reference printed on the installed part and check whether it matches the catalogue reference 6040211. If it is not visible, do not identify the part from its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms and faults that the safety valve 6040211 resolves
The safety valve releases pressure when the circuit exceeds its setting. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
Water continuously drips from the safety valve, even when the boiler is off.
Cause: The valve seat does not seal and allows water to escape even without pressure spikes.
With the system cold, check the pressure on the gauge: if it is within the normal range and it continues to drip, the fault is in the seal, not the pressure.
- 02
The heating circuit loses pressure and needs to be refilled from time to time.
Cause: A slow and steady leak through the valve can go unnoticed and result in that progressive loss.
Also check the expansion vessel and bleed the radiators before assuming it's the valve.
- 03
The valve leaks water just when the boiler heats strongly.
Cause: If the circuit exceeds the set pressure of 3 bar at that moment, the valve acts as it should to protect the installation.
Check the cold fill pressure and the condition of the expansion vessel before replacing the valve: if it is discharged, the pressure rises too much when heating.
- 04
After bleeding the valve, it continues to drip and doesn't fully close.
Cause: Lime deposits on the seat can prevent the valve from resealing after bleeding.
Bleed several times in a row with force; if the jet cleans the seat and then closes, it wasn't necessary to replace it.
Fault codes for Sime that this part resolves.
| Code | Fault | Diagnosis and solution |
|---|---|---|
| AL 03 | High water pressure | The boiler detects that the water pressure exceeds 2.8 bar. This can cause inefficient operation or damage to the system, so the boiler stops to protect itself. If the safety valve is not functioning properly, the pressure may continue to rise, which could lead to a more serious fault. |
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Data sheet for the safety valve Sime 6040211
- Catalogue reference
- 6040211
- Brand
- Sime
- Type of part
- Safety valves
- Units in stock
- 0 units
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- 1-2 business days
- Return
- 14 days
Data read on the part and in the manufacturer's documentation
What we have not been able to verify does not appear here.
- Setpoint
- 3 bar
- Manufacturer
- Watts