Biasi Fan Extractor Micon 24 E Ref. BI1336104

Biasi Fan Extractor Micon 24 E Ref. BI1336104

The Biasi Micon 24 E fan is a flue gas extractor responsible for evacuating combustion gases and generating the necessary draft for the boiler to start. When this part fails, the boiler does not ignite or locks out due to flue gas evacuation failure, potentially displaying the fault code 05E: Fan control anomaly. It is compatible with boilers from the Manaut Micon range, such as the Micon 24 and Micon 24E, as well as models from the Manaut Minox and Biasi M90 ranges. A technician must confirm through diagnosis whether replacement is necessary when the mentioned symptoms occur.

Type of part
Extractor fans
Catalogue reference
BI1336104
Warranty
1 year
VAT included Stock · 7 units
Compatibility

Boilers Biasi compatible with reference BI1336104

Extractor with reference BI1336104. Five confirmed compatibilities: Micon 24 and Micon 24E.

Verified compatibility

Boiler modelFamilyVerification
Manaut Micon 24Biasi MiconVerified
Biasi Micon 24EBiasi MiconVerified
Biasi Minox 24Biasi MinoxVerified
Biasi Minox 24EBiasi MinoxVerified
Biasi M90 24SBiasi M90Verified

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if the part number BI1336104 is the one for your boiler.

The part reference, model, and equipment revision must be verified against the manufacturer's documentation.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference BI1336104. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms that require diagnosis in the extractor BI1336104

The extractor evacuates the combustion gases with forced draft. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The boiler does not ignite and shows a fault related to the flue or exhaust.

    Cause: The extractor does not achieve the necessary flow rate for the air pressure switch to confirm the smoke evacuation, which causes the control board to block the gas.

    First, check if the chimney or the flue is blocked by soot or any external element before replacing the fan.

  • 02

    The fan is making a noise or vibration that can be felt even from outside the boiler.

    Cause: The wear of the bearing or dirt on the impeller blades creates an imbalance that is transmitted to the entire casing.

    Touch the casing of the extractor with the boiler on, carefully, and check if the vibration is more intense there than in the rest of the equipment.

  • 03

    The extractor starts when the boiler is turned on, but it stops before the flame ignites.

    Cause: This may be caused by a motor failure that does not maintain the necessary rotation speed throughout the sweeping and ignition cycle.

    Check if the extractor reaches normal speed or if it runs at half power before stopping.

  • 04

    After the summer without use, the boiler does not start on the first attempt even though it was working well before.

    Cause: The extractor shaft may have seized due to prolonged inactivity, especially if it has accumulated dust or moisture.

    Try to free the shaft by carefully turning the impeller by hand before assuming that the part is faulty.

  • 05

    The boiler turns on but locks out after a few seconds, during the startup.

    Cause: If the extractor loses revolutions right after the initial start, the air pressure switch stops detecting the extraction and cuts off the gas.

    Observe if the noise or the rotation of the extractor changes just before the blockage; that moment usually indicates where the fault is.

Fault codes Manaut that require diagnosis

CodeFaultTechnical checks
05EFan control anomalyThe fan does not start or does not develop the minimum depression, and the flue pressure switch does not switch; the PCB detects a fan control fault. Check voltage/power supply to the motor, free rotation, and pressure in Pa at the pressure switch (and obstructions in the chimney).

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Data sheet for the Biasi extractor BI1336104

Catalogue reference
BI1336104
Uniclima internal SKU
ECMM24E
Brand
Manaut
Type of part
Extractor fans
Units in stock
7 units
Status
Refurbished
Warranty
1 year
Shipping
Delivery time shown at checkout
Return
14 days

Part data and available documentation

Contrast the label codes, PCB, and revision with the installed part; they are not necessarily equivalent references.

frequency
0Hz
power
????W
Before purchasing
  • There is a manufacturer reference suggested by a single external source (code GC E83-191, range M90: Parva/Riva Compact/Riva Plus); since it comes from only one source, it is not included as confirmed data, and it does not match what the catalog states.
Documentation

Manuals and technical documentation

Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.

Frequently asked questions

Frequently asked questions about the extractor BI1336104

Is this extractor fan compatible with the Biasi Micon 24 E boiler?
Yes, the Biasi Manaut Extractor Micon 24 E fan (Ref. BI1336104) is compatible with the Micon 24 E model, as well as with the Micon 24, Minox 24, Minox 24E, and M90 24S models.
What fault indicates that this fan needs to be replaced in the M90 24S boiler?
A starting failure due to flue gas issues, excessive noise during operation, or the boiler locking due to an extraction error are symptoms that indicate the need to replace the fan.
How many models are compatible with this fan?
This fan is compatible with a total of 5 models: Micon 24, Micon 24E, Minox 24, Minox 24E, and M90 24S.
What fault code is associated with this fan?
The fan has the fault code 05E documented.
What is the reference for this extractor fan?
ECMM24E is Uniclima’s internal SKU for locating this listing. To confirm compatibility, check the manufacturer’s reference and the exact appliance model.

Spare parts related to Biasi Manaut Micon

Delivery calculated by destination Delivery time shown at checkout
1-year warranty inspected and tested
14-day return uninstalled parts
Technical support we verify your model
Biasi Fan Extractor Micon 24 E Ref. BI1336104