Extractor LN2 E18C0090NH · N911650200 for Saunier Duval Thema F24 NOx
To confirm: The extractor is the fan that evacuates the fumes and maintains the draft of the boiler. This unit has a motor with a Hall sensor and operates at 230 V.
- Type of part
- Extractor fans
- Status
- Refurbished
- internal SKU
- EXT012
- Warranty
- 1 year
LN2 boilers compatible
Extractor. A proven compatibility: Saunier Duval Thema F24 NOX. There are 3 other models that we are still verifying.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| LN2 s.r.l. Saunier Duval Thema F24 NOx | LN2 s.r.l. | Contrasted |
Models pending verification
These models are associated with this reference, but we have not finished verifying them yet, so we do not consider them compatibleIf your boiler is one of them, send us a photo of the part you are going to replace and we will verify it before you purchase.
| LN2 s.r.l. Hermann Supermicra Ecoplus (24 kW and 24 SE) | LN2 s.r.l. | Unconfirmed |
|---|---|---|
| LN2 s.r.l. Hermann Supermaster Ecoplus | LN2 s.r.l. | Unconfirmed |
| LN2 s.r.l. Saunier Duval Fortune | LN2 s.r.l. | Unconfirmed |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if it is the part for your boiler
The part reference, model, and equipment revision must be verified against the manufacturer's documentation.
- Look for the printed code N911650200 (or N 911650200) and the type EV100MVG/C/120/E18CO + Hall on the label of the assembly.
- In the motor, check E18C0090NH (230 V · 50 Hz · 42 W) and MAT:1004083520 0036.0. The 4353778 is part of the assembly.
- Do they write the motor E18CO090NH (with O) or E18C0090NH (with zero) and the fan as 035003719 or H035003719? Compare letter by letter.
- Read the model on the rating plate of your boiler: the confirmed one is the Thema F24 NOX.
- Any questions? Send us a photo of your part's label and the boiler's rating plate from Contact, or call us at 911 17 77 77.
Symptoms that require diagnosis in the extractor
The extractor evacuates the combustion gases with forced draft. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The boiler stops with fault code F32: fan or air extraction failure.
Cause: Blocked or poorly connected fan, electronic fault, or obstructed flue.
Have a technician check the fan, its connector, and the flue.
Fault codes LN2 s.r.l. that require diagnosis
| Code | Fault | Technical checks |
|---|---|---|
| F32 | Fan or air extraction fault. | Have a technician check it: it could be a blocked fan, its connector, or a blocked flue. |
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Extractor LN2 s.r.l.
- Uniclima internal SKU
- EXT012
- Brand
- LN2 s.r.l.
- Type of part
- Extractor fans
- Units in stock
- 6 units
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- Delivery time shown at checkout
- Return
- 14 days
Part data and available documentation
Contrast the label codes, PCB, and revision with the installed part; they are not necessarily equivalent references.
- Printed code of the assembly
- N911650200
- Type of the extraction unit
- EV100MVG/C/120/E18CO+hall
- Engine model
- E18C0090NH
- Hall marked on the label
- Hall
- Voltage
- 230V AC
- Frequency
- 50Hz
- Power
- 42W
- Motor protection rating
- IP00
- Motor class
- CL.H
- Motor marking
- RO
- Marked number of the set
- 4353778
- MAT marking of the motor
- MAT:1004083520 0036.0
- Date marked on the motor
- 08/04/10
- Conformity marking
- CE
- Source of additional data
- Declared information; auxiliary references and applications without equivalent from the accredited manufacturer.
- Inventory — Hall sensor
- indicated on label
- Inventory — CE Marking
- visible
- Additional data — Voltage
- 230 V
- Additional data — Power
- 43 W
- Additional data — Frequency
- 50 Hz (write 60 Hz) ·
- Associated references
- No OEM reference for the boiler is confirmed. N911650200 appears in the Reference column; it has not been validated as OEM.
- Additional markings
- EV100MVG/C/120/E18CO+Hall (type of assembly); indicated Hall sensor; ebm-papst motor M2E068-DF.
- Pending applications to verify
- THEMA F24 NOX (compatible with reference; pending independent confirmation).
- To confirm: Hermann Supermicra Ecoplus (24 kW and 24 SE) — and they mention 24 kW and 24 SE, without variant. None mention N911650200.
- To be confirmed: Hermann Supermaster — for H035003719 (without "Ecoplus")
- To confirm: Saunier Duval Fortune — for H035003719
- Do not confuse: 911610111 — SIT EV100M/C/108/E18CO fan of 50 W, which is listed as original Immergas; an Immergas catalog lists IMM1017997 for the 50 W one. Unconfirmed — It is the C/108 variant of 50 W; the label says C/120 and 42 W.
- Without confirmation: N911650200, 4353778 or 1004083520, and no manufacturer's document certifies the equivalence with the codes. Compare the motor and the PCB of your boiler.
- and they provide a Hermann fan for the Thema NOX F24. unite 035003719 with the motor E18C0090NH; H035003719 with LNE18C0090NH. None quote N911650200.