Extractor LN2 E18C0090NH · N911650200 for Saunier Duval Thema F24 NOx
Refurbished LN2 s.r.l. Extractor fans LN2

Extractor LN2 E18C0090NH · N911650200 for Saunier Duval Thema F24 NOx

To confirm: The extractor is the fan that evacuates the fumes and maintains the draft of the boiler. This unit has a motor with a Hall sensor and operates at 230 V.

Type of part
Extractor fans
internal SKU
EXT012
Warranty
1 year
VAT included Stock · 6 units
Compatibility

LN2 boilers compatible

Extractor. A proven compatibility: Saunier Duval Thema F24 NOX. There are 3 other models that we are still verifying.

Proven compatibility

Boiler modelFamilyVerification
LN2 s.r.l. Saunier Duval Thema F24 NOxLN2 s.r.l.Contrasted

Models pending verification

These models are associated with this reference, but we have not finished verifying them yet, so we do not consider them compatibleIf your boiler is one of them, send us a photo of the part you are going to replace and we will verify it before you purchase.

LN2 s.r.l. Hermann Supermicra Ecoplus (24 kW and 24 SE)LN2 s.r.l.Unconfirmed
LN2 s.r.l. Hermann Supermaster EcoplusLN2 s.r.l.Unconfirmed
LN2 s.r.l. Saunier Duval FortuneLN2 s.r.l.Unconfirmed

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if it is the part for your boiler

The part reference, model, and equipment revision must be verified against the manufacturer's documentation.

  1. Look for the printed code N911650200 (or N 911650200) and the type EV100MVG/C/120/E18CO + Hall on the label of the assembly.
  2. In the motor, check E18C0090NH (230 V · 50 Hz · 42 W) and MAT:1004083520 0036.0. The 4353778 is part of the assembly.
  3. Do they write the motor E18CO090NH (with O) or E18C0090NH (with zero) and the fan as 035003719 or H035003719? Compare letter by letter.
  4. Read the model on the rating plate of your boiler: the confirmed one is the Thema F24 NOX.
  5. Any questions? Send us a photo of your part's label and the boiler's rating plate from Contact, or call us at 911 17 77 77.
Diagnosis and fault codes

Symptoms that require diagnosis in the extractor

The extractor evacuates the combustion gases with forced draft. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The boiler stops with fault code F32: fan or air extraction failure.

    Cause: Blocked or poorly connected fan, electronic fault, or obstructed flue.

    Have a technician check the fan, its connector, and the flue.

Fault codes LN2 s.r.l. that require diagnosis

CodeFaultTechnical checks
F32Fan or air extraction fault.Have a technician check it: it could be a blocked fan, its connector, or a blocked flue.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Extractor LN2 s.r.l.

Uniclima internal SKU
EXT012
Brand
LN2 s.r.l.
Type of part
Extractor fans
Units in stock
6 units
Status
Refurbished
Warranty
1 year
Shipping
Delivery time shown at checkout
Return
14 days

Part data and available documentation

Contrast the label codes, PCB, and revision with the installed part; they are not necessarily equivalent references.

Printed code of the assembly
N911650200
Type of the extraction unit
EV100MVG/C/120/E18CO+hall
Engine model
E18C0090NH
Hall marked on the label
Hall
Voltage
230V AC
Frequency
50Hz
Power
42W
Motor protection rating
IP00
Motor class
CL.H
Motor marking
RO
Marked number of the set
4353778
MAT marking of the motor
MAT:1004083520 0036.0
Date marked on the motor
08/04/10
Conformity marking
CE
Source of additional data
Declared information; auxiliary references and applications without equivalent from the accredited manufacturer.
Inventory — Hall sensor
indicated on label
Inventory — CE Marking
visible
Additional data — Voltage
230 V
Additional data — Power
43 W
Additional data — Frequency
50 Hz (write 60 Hz) ·
Associated references
No OEM reference for the boiler is confirmed. N911650200 appears in the Reference column; it has not been validated as OEM.
Additional markings
EV100MVG/C/120/E18CO+Hall (type of assembly); indicated Hall sensor; ebm-papst motor M2E068-DF.
Pending applications to verify
THEMA F24 NOX (compatible with reference; pending independent confirmation).
Before purchasing
  • To confirm: Hermann Supermicra Ecoplus (24 kW and 24 SE) — and they mention 24 kW and 24 SE, without variant. None mention N911650200.
  • To be confirmed: Hermann Supermaster — for H035003719 (without "Ecoplus")
  • To confirm: Saunier Duval Fortune — for H035003719
  • Do not confuse: 911610111 — SIT EV100M/C/108/E18CO fan of 50 W, which is listed as original Immergas; an Immergas catalog lists IMM1017997 for the 50 W one. Unconfirmed — It is the C/108 variant of 50 W; the label says C/120 and 42 W.
  • Without confirmation: N911650200, 4353778 or 1004083520, and no manufacturer's document certifies the equivalence with the codes. Compare the motor and the PCB of your boiler.
  • and they provide a Hermann fan for the Thema NOX F24. unite 035003719 with the motor E18C0090NH; H035003719 with LNE18C0090NH. None quote N911650200.
Frequently Asked Questions

Frequently asked questions about the extractor

How do I identify the extractor N911650200 · E18C0090NH?
Look at the label of the assembly: it is printed N911650200 and the type EV100MVG/C/120/E18CO with Hall sensor. The motor is the E18C0090NH (230 V AC, 50 Hz, 42 W, IP00, class H) with the marking MAT:1004083520 0036.0.
Is it compatible with my Saunier Duval Thema F24 NOX?
Yes. Confirmed: for the Thema F24 NOX. Additionally, (035003719 / H035003719) and (H035003719) list a Hermann fan for the "Thema NOX F24". Not confirmed: N911650200. If your boiler is different, call us at 911 17 77 77 or send us a photo of the label and the PCB from Contact.
What other boilers use the fan 035003719 (H035003719)?
(035003719 / H035003719) and (H035003719) are provided for the Hermann Supermicra Ecoplus 24 kW and 24 SE; for the Supermicra Ecoplus without variant; also for the Supermaster Ecoplus; for the Supermaster (without Ecoplus) and the Fortune. They write H035003719; write 035003719. The fact that it is the same code is stated. These are data about the fan, not about N911650200.
Is it the same as the 035003719 from Hermann?
The manufacturer does not certify it. It is titled "HERMANN 035003719 FAN SIT E18C0090NH EV100M HALL" and combines H035003719 with "LNE18C0090NH", which contains the model from our label. It provides 911650200 for the E18CO090NH. No mention of N911650200: compare the motor and your boiler. Registered data: the brand LN2 s.r.l. for the part; it provides the brand Hermann / Saunier Duval for the code 035003719.
What do N911650200, E18C0090NH, and EV100MVG mean on the label?
On the label, N911650200 is the printed code of the assembly, EV100MVG/C/120/E18CO + Hall is the type, and E18C0090NH is the model of the motor. Write E18CO090NH (with O) and E18C0090NH (with zero); without additional confirmation, explain the difference. The motor is from SIT S.p.A. and indicates an ebm-papst M2E068-DF: they do not match.
What voltage, power, and frequency does it have?
230 V and 42 W according to our label, and (: 43 W). 50 Hz according to the label; write 60 Hz. The ebm-papst manual states for the M2E068-DF13-79 115 V and 60 Hz; we do not know if it is the same variant. The same manual indicates 120 W absorbed and 70 W useful. It states 230 V and 50 Hz.
Who should install this extractor?
A qualified technician: it is a 230 V fan in the flue gas exhaust of a gas boiler. Disconnect the boiler from the power supply before touching it.