Junkers Euromaxx ZWC24-1MF2A23 Extractor Fime Ref. 87167711010
RefurbishedJunkersExtractorsFIME

Junkers Euromaxx ZWC24-1MF2A23 Extractor Fime Ref. 87167711010

Stock · 3 units

FIME extractor for Junkers Euromaxx and Cerastar boilers, with the manufacturer embossed on the casing itself. Operates at 230-240V, 50Hz, and 38W, with CE marking. It is replaced when there is a flue gas evacuation failure, excessive noise, or the boiler locks due to draft failure.

VAT included

Compatibility

Junkers boilers compatible with reference 87167711010

Extractor with reference 87167711010. Six confirmed compatibilities: ZWC24-1MFA23 and ZWC24-1MFA31.

Proven compatibility

Boiler modelFamilyVerification
Junkers ZWC24-1MFA23Junkers Euromaxx ZWC 24Contrasted
Junkers ZWC24-1MFA31Junkers Euromaxx ZWC 24Contrasted
Junkers ZWC24-1MF2A23Junkers Euromaxx ZWC 24Contrasted
Junkers ZWC24-1MF2A31Junkers Euromaxx ZWC 24Contrasted
Junkers ZC24-1MFA23Junkers Euromaxx ZC 24Contrasted
Junkers ZC24-1MFA31Junkers Euromaxx ZC 24Contrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. 87167711010 is the part for your boiler

What determines it is not the boiler model, but the reference printed on the part you already have installed.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference 87167711010. If it is not visible, do not identify the part by its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms and faults that the extractor 87167711010 resolves.

The extractor evacuates the combustion gases with forced draft. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The boiler does not ignite and shows an error related to the flue or the pressure switch.

    Cause: The extractor does not create the necessary depression for the flue pressure switch to close the start contact.

    Check that the silicone tubes of the flue pressure switch are not loose, cracked, or blocked before considering that the extractor is faulty.

  • 02

    The extractor makes a metallic rubbing noise or vibrates when it rotates.

    Cause: The impeller may be dirty or the bearing may have worn out due to continuous use.

    Turn the impeller by hand with the boiler off; if you feel rubbing or imbalance, check for visible soot that needs to be cleaned.

  • 03

    The boiler ignites but locks out after a few seconds with an evacuation fault code.

    Cause: An extractor that loses power does not maintain the flow required for safety, and the control unit cuts off the gas.

    Check that power is reaching the connector of the fan when the boiler attempts to start, to rule out a wiring or PCB issue.

  • 04

    The extractor does not start at all when trying to turn it on.

    Cause: The motor may be burned out or, if it has a start capacitor, it may be faulty.

    Check if there is power to the extractor at the moment of the ignition attempt; if there is power and it does not respond, the motor is confirmed to be faulty.

Fault codes from Junkers that this part resolves.

CodeFaultDiagnosis and solution
C7No fan speed signal.The extractor (Fime fan) does not rotate or does not deliver the tachometric signal to the Heatronic; check the power supply to the motor and the presence of rpm pulses at its connector, as well as the fan's integrated wiring/sensor.
C6The pressure switch does not close.If the extractor does not generate sufficient depression/draught, the air pressure switch does not switch; check that the fan starts and moves flow, measure depression with a manometer and inspect the tubes to the pressure switch and the fan/wiring itself.
C1The pressure switch has activated during operation.Drop in flow/draft due to low revolutions or intermittent extractor fault causes the pressure switch to open during operation; verify fan rpm/consumption and speed signal, and check pressure in the pressure switch while operating.
CATurbine revolutions too high.Anomaly in the extractor control or erroneous reading of its tachometric signal; check the speed sensor/fan wiring and ensure the measured rpm (service menu or tachometer) do not exceed the specified range.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Junkers 87167711010 extractor datasheet

Catalogue reference
87167711010
Brand
Junkers
Type of part
Extractors
Units in stock
3 units
Status
Refurbished
Warranty
1 year
Shipping
1-2 business days
Return
14 days

Data read on the part and in the manufacturer's documentation

What we have not been able to verify does not appear here.

Manufacturer
FIME (cast in the housing)
Nominal voltage
230-240V
Frequency
50Hz
Power
38W
Marked
CE
Frequently Asked Questions

Frequently asked questions about the extractor 87167711010

Who manufactures the extractor for the Junkers Euromaxx ZWC24-1MF2A23?
FIME; the name is molded into the housing of the part itself.
What voltage and power does this extractor Ref. 87167711010 have?
230-240V, 50Hz and 38W, according to the label.
What models are compatible with the extractor ECEZWC2423?
It is compatible with the models from the Junkers Euromaxx range ZWC 24: ZWC24-1MFA23, ZWC24-1MFA31, ZWC24-1MF2A23, ZWC24-1MF2A31 and from the Junkers Euromaxx range ZC 24: ZC24-1MFA23, ZC24-1MFA31.
What fault codes are documented for this extractor?
The documented fault codes are C7, C6, C1, and CA.
Does the FIME extractor of the Euromaxx ZWC 24-1MF2A23 have CE marking?
Yes, it is stated on the part's label.

Spare parts related to Junkers Junkers Euromaxx ZWC 24

Delivery 1–2 daysworking days, mainland Spain
1-year warrantyreviewed and tested
14-day returnuninstalled parts
Technical supportwe verify your model
Junkers Euromaxx ZWC24-1MF2A23 Extractor Fime Ref. 87167711010