Vaillant Turbotec Plus VMW ES 21 245 4 5 R3 Extractor Ref. 190237

Vaillant Turbotec Plus VMW ES 21 245 4 5 R3 Extractor Ref. 190237

70 €VAT includedIn stock · 1 unit

Extractor: refurbished spare part that evacuates combustion gases with forced draft. Useful if it doesn't start due to draft failure, makes noise, or doesn't spin. Compatible with VMW 21/245/4-3 R3, VMW 21/245/4-5, VMW 21/245/4-5 R3 (ref. 190237). Includes a one-year warranty and delivery within 2–4 working days in the EU.

1
Consult via WhatsApp
Delivery in 2–4 working days
1-year warranty
14-day return
Technical support

Key Data

Reference
190237
Brand
Vaillant
Type of part
Extractors
Available units
1 unit in stock
Status
Refurbished
Warranty
1 year
Shipping
2–4 working days (EU)
Return
14 days

The same part (ref. 190237) equips these models. Verified compatibility; check the reference before purchasing.

Vaillant Turbotec Plus VMW ES (VMW 21/245)

  • VMW 21/245/4-3 R3
  • VMW 21/245/4-5
  • VMW 21/245/4-5 R3

Vaillant Turbotec Plus VMW ES (VMW 255)

  • VMW 255/4-7
  • VMW 255/4-7 R3

Fault codes related to this part (not the entire boiler). They usually have more possible causes: first rule out electrodes, wiring/connections, and gas supply. Verified with ≥3 sources.

CodeWhat does it mean?Cause and diagnosis (this part)
F.32Fan faultThe extractor (fan) does not start or is not detected by the PCB (no Hall/tachometer signal), causing the boiler to lock out. Check the power supply to the fan and the feedback signal from the fan to the PCB.
F.37Divergence of the number of revolutions during operationThe extractor operates outside the intended range (seized bearings, dirt, or defective fan Hall sensor), causing a discrepancy in rpm measured by the electronics. Check fan rpm/feedback in service test and mechanical condition of the extractor.
F.33The pressure capsule does not turn onIf the extractor does not generate the necessary depression, the pressure switch (manometric capsule) does not switch, and the boiler locks out. Check that the fan reaches rpm and creates depression (Venturi connections/clean tubes) and that the pressure switch switches when the fan starts.
How do I know if this extractor/fan is the one for my boiler?
Check the reference 190237 printed and ensure your model is on the list of compatible ones; also compare the connections with the original part.
What is it used for?
The extractor/fan evacuates the combustion gases (forced draught).
Does it not start due to a draught fault, make noise, or not spin?
Seized, noisy, or unpowered fan.
Which models is it suitable for?
Part shared by various models (see Compatibility). If your model does not appear, send us a photo of the marking and we will confirm it.
Installation and recommendations
Check the connector, the 230 V power supply, and free rotation.
What does refurbished mean and what coverage does it have?
Part removed from a boiler out of service, inspected and tested. Includes 1-year warranty and 14-day return policy. Delivery within 2–4 working days in the EU.

Spare Parts Related Boiler Turbotec Plus VMW ES 21 245 4 5 R3