Junkers Euromaxx Gas Valve ZWC24 MF2A 23 SIT Ref. 8747003700
When you turn on the hot water tap or start the heating, the Junkers Euromaxx ZWC24 MF2A 23 SIT gas valve is responsible for regulating and allowing the flow of gas to the burner. If this part fails, you will notice that the boiler does not ignite, there may be flame lockouts, or the gas modulation will not be correct, which can generate the fault code F7. This valve is compatible with several boilers, such as the ZWC 24/28-1 MFA, ZSC 24-3 MFA, and ZWN 24-7 AE, among others. It is replaced when it shows faults that prevent its proper functioning.
VAT included
Consult via WhatsAppJunkers boilers compatible with reference 8747003700
Gas valve with reference 8747003700. 31 verified compatibilities: ZWC 24/28-1 MFA and ZWC 24/28-1 MFK.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Junkers ZWC 24/28-1 MFA | Ceraclass Excellence / Comfort (ZWC) | Contrasted |
| Junkers ZWC 24/28-1 MFK | Ceraclass Excellence / Comfort (ZWC) | Contrasted |
| Junkers ZWC 24/28-3 MFA | Ceraclass Excellence / Comfort (ZWC) | Contrasted |
| Junkers ZWC 24/28-3 MFK | Ceraclass Excellence / Comfort (ZWC) | Contrasted |
| Junkers ZWC 24-1 MF2A | Ceraclass Excellence / Comfort (ZWC) | Contrasted |
| Junkers ZWC 24-1 MF2K | Ceraclass Excellence / Comfort (ZWC) | Contrasted |
| Junkers ZWC 28-1 MF2A | Ceraclass Excellence / Comfort (ZWC) | Contrasted |
| Junkers ZWC 28-1 MF2K | Ceraclass Excellence / Comfort (ZWC) | Contrasted |
| Junkers ZWC 28/32-1 MFA | Ceraclass Excellence / Comfort (ZWC) | Contrasted |
| Junkers ZWC 30/30-3 MFA | Ceraclass Excellence / Comfort (ZWC) | Contrasted |
| Junkers ZWC 35/35-3 MFA | Ceraclass Excellence / Comfort (ZWC) | Contrasted |
| Junkers ZSC 24-3 MFA | Ceraclass Excellence (ZSC - heating only) | Contrasted |
| Junkers ZSC 24-3 MFK | Ceraclass Excellence (ZSC - heating only) | Contrasted |
| Junkers ZSC 28-3 MFK | Ceraclass Excellence (ZSC - heating only) | Contrasted |
| Junkers ZSC 30-3 MFA | Ceraclass Excellence (ZSC - heating only) | Contrasted |
| Junkers ZSC 35-3 MFA | Ceraclass Excellence (ZSC - heating only) | Contrasted |
| Junkers ZC 24-1 MFA | Cerastar / Ceraclass (ZC - heating only) | Contrasted |
| Junkers ZC 24-1 MFK | Cerastar / Ceraclass (ZC - heating only) | Contrasted |
| Junkers ZC 24-1 MF2A | Cerastar / Ceraclass (ZC - heating only) | Contrasted |
| Junkers ZC 28-1 MFA | Cerastar / Ceraclass (ZC - heating only) | Contrasted |
| Junkers ZC 28-1 MFK | Cerastar / Ceraclass (ZC - heating only) | Contrasted |
| Junkers ZWE 23-4 A | Eurostar / Cerastar (ZWE / ZWSE) | Contrasted |
| Junkers ZWE 24-4 HA | Eurostar / Cerastar (ZWE / ZWSE) | Contrasted |
| Junkers ZWE 24-4 HK | Eurostar / Cerastar (ZWE / ZWSE) | Contrasted |
| Junkers ZWE 28-4 HA | Eurostar / Cerastar (ZWE / ZWSE) | Contrasted |
| Junkers ZWSE 23-4 MFK | Eurostar / Cerastar (ZWE / ZWSE) | Contrasted |
| Junkers ZWSE 28-4 MFA | Eurostar / Cerastar (ZWE / ZWSE) | Contrasted |
| Junkers ZWSE 28-5 MFA | Eurostar / Cerastar (ZWE / ZWSE) | Contrasted |
| Junkers ZWSE 35-6 MFA | Eurostar / Cerastar (ZWE / ZWSE) | Contrasted |
| Junkers ZWN 24-7 AE | ZWN | Contrasted |
| Junkers ZWN 24-7 KE | ZWN | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if ref. 8747003700 is the part for your boiler
What determines it is not the boiler model, but the reference printed on the part you already have installed.
- Find the reference printed on the installed part and check whether it matches the catalogue reference 8747003700. If it is not visible, do not identify the part by its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms and faults that the gas valve 8747003700 resolves.
The gas valve regulates and modulates the gas flow to the burner. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The boiler ignites well for domestic hot water but not for heating, or vice versa.
Cause: The valve has two independent solenoid valves (EV1 and EV2), and only one of them is failing.
Check the exact ignition failure mode before replacing the entire gas valve; narrow down the problem for the technician.
- 02
An electrical click is heard in the gas valve, but no flame appears.
Cause: One of the two solenoid valves receives current but does not physically open the gas passage.
Check that both electrical connectors of the valve are properly fitted before replacing it.
- 03
You notice a slight smell of gas right after the boiler turns off.
Cause: One of the solenoid valves does not close completely at the end of the cycle.
Close the main gas valve and ventilate the area; do not force ignition until the installation has been inspected.
- 04
The flame takes longer to appear after the ignition click, with a small jolt when it lights.
Cause: The gas flow opens with a delay because the solenoid valve does not respond instantly to the electrical command.
Check the voltage reaching the gas valve with the boiler running before declaring it faulty.
Fault codes from Junkers that this part resolves.
| Code | Fault | Diagnosis and solution |
|---|---|---|
| F7 | Problems with the ignition of the boiler. | This happens when the signal indicating that the flame is present is not correct. If the gas valve does not open properly, the boiler will not be able to ignite correctly, which can lead to this fault. |
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Data sheet for the gas valve Junkers 8747003700
- Catalogue reference
- 8747003700
- Brand
- Junkers
- Type of part
- Gas valves
- Units in stock
- 6 units
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- Delivery time shown at checkout
- Return
- 14 days
Data read on the part and in the manufacturer's documentation
What we have not been able to verify does not appear here.
- Identification of solenoid valves
- EV1 and EV2 (brands embedded in the brass plate, rear view)
- The brands 'EV1' and 'EV2' identify the two solenoid valves of the part; they are not a purchase reference.
Manuals and technical documentation
Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.
- Junkers ZWC 24/28-3 MFK manual (PDF)Document © Junkers, provided as a technical reference.