Gas Valve ZWC/ZWN Ref. 8747003700
RefurbishedJunkersGas valvesSIT

Gas Valve ZWC/ZWN Ref. 8747003700

Stock · 5 units

The gas valve ZWC/ZWN Ref. 8747003700 from SIT regulates and allows the flow of gas to the burner according to the indications of the boiler's PCB. When it fails, the boiler may not ignite, experience flame lockouts, or have modulation issues. This can manifest with faults such as FA, which indicates that a flame is still detected after the gas has been disconnected, or d7, which signals a fault in the regulating valve. This valve is compatible with models such as ZWC 24/28-1 MFA, ZSC 24-3 MFA, and ZWN 24-7 AE, among others. It is recommended to replace it if the mentioned symptoms occur or during the preventive maintenance of the boiler.

VAT included

Compatibility

Junkers boilers compatible with reference 8747003700

Gas valve with reference 8747003700. 31 verified compatibilities: ZWC 24/28-1 MFA and ZWC 24/28-1 MFK.

Proven compatibility

Boiler modelFamilyVerification
Junkers ZWC 24/28-1 MFACeraclass Excellence / Comfort (ZWC)Contrasted
Junkers ZWC 24/28-1 MFKCeraclass Excellence / Comfort (ZWC)Contrasted
Junkers ZWC 24/28-3 MFACeraclass Excellence / Comfort (ZWC)Contrasted
Junkers ZWC 24/28-3 MFKCeraclass Excellence / Comfort (ZWC)Contrasted
Junkers ZWC 24-1 MF2ACeraclass Excellence / Comfort (ZWC)Contrasted
Junkers ZWC 24-1 MF2KCeraclass Excellence / Comfort (ZWC)Contrasted
Junkers ZWC 28-1 MF2ACeraclass Excellence / Comfort (ZWC)Contrasted
Junkers ZWC 28-1 MF2KCeraclass Excellence / Comfort (ZWC)Contrasted
Junkers ZWC 28/32-1 MFACeraclass Excellence / Comfort (ZWC)Contrasted
Junkers ZWC 30/30-3 MFACeraclass Excellence / Comfort (ZWC)Contrasted
Junkers ZWC 35/35-3 MFACeraclass Excellence / Comfort (ZWC)Contrasted
Junkers ZSC 24-3 MFACeraclass Excellence (ZSC - heating only)Contrasted
Junkers ZSC 24-3 MFKCeraclass Excellence (ZSC - heating only)Contrasted
Junkers ZSC 28-3 MFKCeraclass Excellence (ZSC - heating only)Contrasted
Junkers ZSC 30-3 MFACeraclass Excellence (ZSC - heating only)Contrasted
Junkers ZSC 35-3 MFACeraclass Excellence (ZSC - heating only)Contrasted
Junkers ZC 24-1 MFACerastar / Ceraclass (ZC - heating only)Contrasted
Junkers ZC 24-1 MFKCerastar / Ceraclass (ZC - heating only)Contrasted
Junkers ZC 24-1 MF2ACerastar / Ceraclass (ZC - heating only)Contrasted
Junkers ZC 28-1 MFACerastar / Ceraclass (ZC - heating only)Contrasted
Junkers ZC 28-1 MFKCerastar / Ceraclass (ZC - heating only)Contrasted
Junkers ZWE 23-4 AEurostar / Cerastar (ZWE / ZWSE)Contrasted
Junkers ZWE 24-4 HAEurostar / Cerastar (ZWE / ZWSE)Contrasted
Junkers ZWE 24-4 HKEurostar / Cerastar (ZWE / ZWSE)Contrasted
Junkers ZWE 28-4 HAEurostar / Cerastar (ZWE / ZWSE)Contrasted
Junkers ZWSE 23-4 MFKEurostar / Cerastar (ZWE / ZWSE)Contrasted
Junkers ZWSE 28-4 MFAEurostar / Cerastar (ZWE / ZWSE)Contrasted
Junkers ZWSE 28-5 MFAEurostar / Cerastar (ZWE / ZWSE)Contrasted
Junkers ZWSE 35-6 MFAEurostar / Cerastar (ZWE / ZWSE)Contrasted
Junkers ZWN 24-7 AEZWNContrasted
Junkers ZWN 24-7 KEZWNContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. 8747003700 is the part for your boiler

What determines it is not the boiler model, but the reference printed on the part you already have installed.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference 8747003700. If it is not visible, do not identify the part by its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms and faults that the gas valve 8747003700 resolves.

The gas valve regulates and modulates the gas flow to the burner. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The boiler does not ignite, or it locks up as soon as you try to start it.

    Cause: One of the solenoid valves of the gas valve does not open and the control board does not detect a flame, so it cuts off the attempt.

    Check that power is reaching the gas valve at the moment of startup and that the ignition electrode is sparking before replacing it.

  • 02

    The flame goes up and down by itself, or it doesn't reach the power you request.

    Cause: The valve modulator does not properly regulate the gas flow to the burner.

    Check that the modulation signal is coming from the PCB and that the gas inlet filter is not dirty.

  • 03

    It smells like gas near the boiler, even when it is turned off.

    Cause: Loss of tightness in the body of the gas valve or in its seals

    Locate the exact point with leak detection spray and turn off the gas before touching anything.

  • 04

    The boiler starts up well but locks out after a few minutes of operation.

    Cause: The flame maintenance solenoid valve gradually loses tightness as it heats up.

    Note if the blockage always takes the same time to appear before considering the gas valve as the culprit.

Fault codes from Junkers that this part resolves.

CodeFaultDiagnosis and solution
FAAfter the gas disconnection: The flame is still detected.The gas valve does not close tightly (leak/blockage) and the control continues to read ionisation current even though the gas has been cut off. Verify with a leak test and observe that the ionisation signal disappears when closed, and that the solenoid valve closes correctly.
d7Fault in the regulating valve.The electronics detect a fault in the gas valve (open/shorted coils or jammed mechanism). Check control voltage and coil continuity/ohmage, and ensure the valve opens/closes by measuring pressure on the ramp.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Data sheet for the gas valve Junkers 8747003700

Catalogue reference
8747003700
Brand
Junkers
Type of part
Gas valves
Units in stock
5 units
Status
Refurbished
Warranty
1 year
Shipping
1-2 business days
Return
14 days

Data read on the part and in the manufacturer's documentation

What we have not been able to verify does not appear here.

model
845 SIGMA
Manufacturing origin
Made in Italy (Padua)
CE Certificate
0063AS4831
Cross code
8 747 003 700
gas
ALLGAS
Maximum inlet pressure
Pi max 60 mbar
Output pressure
Po 1-36 mbar
ev1
24V RAC, 6.5 VA class B
ev2
24V RAC, 2.8 VA class J
modulator
MD MAX 17V DC
Maximum current
MAX 165 mA
Ambient temperature
15/60°C
code (production)
0845105
date (production)
0949
lot
2934903
nr
2271
Frequently Asked Questions

Frequently asked questions about the gas valve 8747003700

Does this gas valve Ref. 8747003700 work for a boiler ZWC 35/35-3 MFA?
Yes, the ZWC 35/35-3 MFA is on the list of boilers compatible with this gas valve.
Does the same valve work for a boiler ZWN 24-7 AE?
Yes, the ZWN 24-7 AE is also listed among the compatible boilers, along with the ZWC and ZWN series.
When should this valve be replaced in a ZWC or ZWN boiler?
When the boiler does not ignite or shows faults related to the gas valve, such as fault codes FA or d7.
How many solenoid valves does the valve of the ZWC/ZWN series have?
Two: EV1 (24V, 6.5VA) and EV2 (24V, 2.8VA), plus a modulator of up to 17V DC.
What is the reference for this gas valve?
The reference for this gas valve is VGCEZWC3535.
How many models are compatible with this gas valve?
A total of 31 models are compatible with the gas valve Ref. 8747003700.

Spare parts related to Junkers Ceraclass Excellence / Comfort (ZWC)

Delivery 1–2 daysworking days, mainland Spain
1-year warrantyreviewed and tested
14-day returnuninstalled parts
Technical supportwe verify your model
Gas Valve ZWC/ZWN Ref. 8747003700