SIT Sigma 848 Gas Valve (0848135) Biasi Myto Condens 24 Ref. BI1313103
SIT Sigma 848 gas valve (code 0848135), identified by external sources as the part used in the Biasi valve ref. BI1313103. Double coil EV1/EV2 with an air/gas ratio of 1:1, for Biasi Myto Condens 24, Myto Condens 35, Myto Condens Inox 24, Rinnova Cond and models from the Advance, Activ and Inovia ranges. It is replaced if the boiler does not ignite or the burner does not modulate.
VAT included
Consult via WhatsAppBoilers Biasi compatible with reference BI1313103
Gas valve with reference BI1313103. Seven confirmed compatibilities: A 12OV and PLUS 25C.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Biasi A 12OV | ACTIVE | Contrasted |
| Biasi PLUS 25C | ADVANCE | Contrasted |
| Biasi 25C | INOVIA | Contrasted |
| Biasi CONDENS 24 | MYTO | Contrasted |
| Biasi CONDENS 35 | MYTO | Contrasted |
| Biasi CONDENS INOX 24 | MYTO | Contrasted |
| Biasi COND | RINNOVA | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if the reference BI1313103 is the part for your boiler
What determines it is not the boiler model, but the reference printed on the part you already have installed.
- Find the reference printed on the installed part and check whether it matches the catalogue reference BI1313103. If it is not visible, do not identify the part from its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms and faults that the gas valve BI1313103 resolves.
The gas valve regulates and modulates the gas flow to the burner. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The boiler does not ignite or locks up as soon as the burner starts.
Cause: The gas valve does not allow the necessary gas to pass for the burner to ignite on the first attempt.
Before changing it, check that the gas shut-off valve is fully open and that there is no air left in the line after a recent intervention.
- 02
The burner does not modulate, it remains stuck at a fixed power.
Cause: A fault in one of the two coils EV1/EV2 breaks the 1:1 air/gas ratio and the modulation stops adjusting.
Check that the fan and the air pressure intake are functioning properly: a fault there also prevents modulation even if the gas valve is in good condition.
- 03
There is a smell of gas near the boiler, especially around the area of the gas valve.
Cause: A gasket or the body of the gas valve can lose tightness and allow gas to escape even if the burner is functioning normally.
Shut off the gas and ventilate immediately; locate the exact point with soapy water before deciding whether to replace the gas valve.
- 04
The boiler starts but shuts down a few seconds after igniting.
Cause: The retention coil does not keep the valve open long enough for the flame to stabilize.
Check the ionization electrode before replacing the gas valve: a poor connection there causes the same fault.
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Data sheet for the gas valve Biasi BI1313103
- Catalogue reference
- BI1313103
- Brand
- Biasi
- Type of part
- Gas valves
- Units in stock
- 5 units
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- 1-2 business days
- Return
- 14 days
Data read on the part and in the manufacturer's documentation
What we have not been able to verify does not appear here.
- Manufacturer
- SIT
- SIT Code
- 0848135
- Maximum inlet pressure (Pi max)
- 60 mbar
- Outlet pressure (Po)
- 0.5-12 mbar
- EV1 coil
- 230V~50Hz, 9.2 VA class B
- EV2 coil
- 230V~50Hz, 2.8 VA class B
- Air/gas ratio
- 1:1
- Ambient temperature
- -10/60°C
- SIT / Biasi equivalence
- SIT Sigma 848 (0.848.135) = Biasi gas valve ref. BI1313103, Advance/Activ/Inovia family
Manuals and technical documentation
Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.
- Manual Biasi CONDENS 35 (PDF)Document © Biasi, provided as a technical reference.