
Wiesberg Gas Valve RSSE 24 - Code 63AP7060/2
When you open the hot water tap or start the heating, the gas valve Wiesberg RSSE 24 - 63AP7060/2 regulates and allows the flow of gas to the burner, following the commands of the control board. If this valve fails, you will notice that the boiler does not ignite, experiences flame lockouts, or the gas modulation is ineffective. It is compatible with boilers from the Wiesberg RSSE range, such as the RSSE 24, among others. A technician must confirm through diagnosis whether it needs to be replaced if you experience these symptoms, as it is essential for the proper functioning of the boiler.
- Type of part
- Gas valves
- Status
- Refurbished
- Catalogue reference
- 95000293
- Warranty
- 1 year
Wiesberg boilers compatible with reference 95000293
Gas valve with reference 95000293. A proven compatibility: RSSE 24.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Wiesberg RSSE 24 | Wiesberg RSSE | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if ref. 95000293 is the part for your boiler
The part reference, model, and equipment revision must be verified against the manufacturer's documentation.
- Find the reference printed on the installed part and check whether it matches the catalogue reference 95000293. If it is not visible, do not identify the part from its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms that require diagnosis in the gas valve 95000293
The gas valve regulates and modulates the gas flow to the burner. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The boiler tries to ignite, you hear a click in the gas valve but no flame appears.
Cause: One of the solenoid valves (EV1 or L1/2) does not open the gas flow to the burner even though it receives the ignition command.
Before changing the gas valve, check with a multimeter that current is reaching the coils EV1 and L1/2 at the moment of ignition.
- 02
The flame rises and falls on its own, or it sounds like it's coughing when modulating.
Cause: The modulator of the gas valve does not properly adjust the opening and allows gas to pass through irregularly.
Measure the gas inlet pressure with a manometer before assuming the fault is in the modulator.
- 03
The boiler locks out and the display shows a flame or gas fault shortly after starting.
Cause: The control unit detects that the burner has not ignited in time because the gas valve has not opened, and it cuts off the supply for safety reasons.
Check that the ignition electrode and the valve wiring are properly connected before replacing it.
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Data sheet for the gas valve Wiesberg 95000293
- Catalogue reference
- 95000293
- Uniclima internal SKU
- VGCRSSE24
- Brand
- Wiesberg
- Type of part
- Gas valves
- Units in stock
- 7 units
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- Delivery time shown at checkout
- Return
- 14 days
Part data and available documentation
Contrast the label codes, PCB, and revision with the installed part; they are not necessarily equivalent references.
- Nominal voltage
- 220/240 V~ 50Hz
- Maximum current
- max 165 mA
- Maximum flow rate
- Q max 6.5 m³/h
- Body code
- 63AP7060/2
- Series
- 827 NOVA
- EV1 class
- Class B, 220/240V~ 50Hz
- Class L1/2
- Class D, 220/240V~ 50Hz
- Maximum opening time (MD max)
- 23 s DC
- Batch numbers / barcode
- 0627128 / 0015 / 2002900 / 0237 / 179029000237
