Spherical Thermometer for Wiesberg RSSE 24 and Unical DUA Boiler
The dial thermometer for the Wiesberg RSSE 24 boiler and Unical DUA measures and controls the temperature of the boiler circuit. If the part fails, you will notice incorrect readings, which may lead to the boiler locking due to a false lack of pressure or not regulating the temperature properly. This thermometer is compatible with the Wiesberg RSSE 24 boiler, among others. A technician must confirm through diagnosis whether it needs to be replaced when it starts showing inaccuracies in the readings.
- Type of part
- Pressure gauges & aquastats
- Status
- Refurbished
- Catalogue reference
- 95000036
- Warranty
- 1 year
Wiesberg boilers compatible with reference 95000036
Pressure gauge with reference 95000036. A proven compatibility: RSSE 24.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Wiesberg RSSE 24 | Wiesberg | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if the part number 95000036 is the one for your boiler
The part reference, model, and equipment revision must be verified against the manufacturer's documentation.
- Find the reference printed on the installed part and check whether it matches the catalogue reference 95000036. If it is not visible, do not identify the part by its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms that require diagnosis on the manometer 95000036
The manometer shows the pressure of the boiler circuit. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The needle does not move, regardless of whether the boiler is cold or hot.
Cause: The capillary has lost the liquid that allows it to react to temperature changes.
Check for kinks, crushes, or signs of leakage in the capillary before declaring the thermometer broken.
- 02
Always set a fixed temperature; it does not change when heating or cooling the circuit.
Cause: The sensor bulb may have moved out of its immersion sleeve and is not in contact with the water.
Check that the bulb is properly seated in its housing before replacing the part.
- 03
The dial is broken, fogged up, or the scale is not clearly readable.
Cause: It is damage to the casing that does not always mean that the internal mechanism has stopped functioning.
Check if the needle moves when starting the boiler, even if the glass is damaged, to determine if it is worth replacing it.
- 04
There is no indication of the water temperature on the boiler's display.
Cause: Without liquid in the capillary or with the bulb outside the sheath, the thermometer stops reflecting any change in temperature.
Gently touch the supply pipe to check if it is really hot even if the thermometer does not indicate it.
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Wiesberg pressure gauge data sheet 95000036
- Catalogue reference
- 95000036
- Uniclima internal SKU
- MTCRSSE24
- Brand
- Wiesberg
- Type of part
- Pressure gauges & aquastats
- Units in stock
- 7 units
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- Delivery time shown at checkout
- Return
- 14 days
Part data and available documentation
Contrast the label codes, PCB, and revision with the installed part; they are not necessarily equivalent references.
- Temperature scale
- 0-120 °C