Acuastato Airindex Boiler Baxi Roca Temperature NGM 13 20 SR
It measures and controls the pressure and temperature of the circuit in the Baxi Roca Temperatura NGM 13 20 SR boiler. If it fails, you will notice incorrect readings that may cause the boiler to lock out due to a false low pressure or not regulate the temperature properly. This aquastat is compatible with models from the Baxi Roca NGM range, ensuring a perfect fit. It is replaced when the readings are inaccurate and affect the operation of the boiler.
VAT included
Consult via WhatsAppBaxi Roca boilers compatible with reference 5699941
Pressure gauge with reference 5699941. A proven compatibility: NGM 13-20 SR.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Baxi Roca NGM 13-20 SR | Baxi Roca NGM | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if the reference 5699941 is the part for your boiler.
What determines it is not the boiler model, but the reference printed on the part you already have installed.
- Find the reference printed on the installed part and check whether it matches the catalogue reference 5699941. If it is not visible, do not identify the part from its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms and faults that the manometer 5699941 solves.
The manometer shows the pressure of the boiler circuit. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The aquastat does not cut off or activate the circuit at the temperature it should.
Cause: The internal electrical contact is stuck or not closing properly, so the control unit does not receive the command to act.
Check that the bulb is properly inserted into the immersion sleeve and has good thermal contact; a poor insertion can give incorrect readings before replacing the part.
- 02
The boiler does not start or does not stop at the expected temperature.
Cause: The sensor of the aquastat is out of calibration and sends the cut-off or activation command out of range.
Compare the actual water temperature with an external thermometer at the same point before replacing the aquastat.
- 03
There is a water leak in the rear threaded fitting.
Cause: The gasket or the brass body of the water heater has lost tightness over time.
Tighten the fitting carefully and check the sealing gasket before considering that the part is perforated.
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Data sheet for the Baxi Roca pressure gauge 5699941
- Catalogue reference
- 5699941
- Brand
- Baxi Roca
- Type of part
- Pressure gauges - Aquastats
- Units in stock
- 5 units
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- 1-2 business days
- Return
- 14 days
Data read on the part and in the manufacturer's documentation
What we have not been able to verify does not appear here.
- Temperature range
- 30-110 °C
- Silkscreened brand
- AIRINDEX