Honeywell Gas Valve VK4115M - Vaillant Turboblock VCM 182/1 E - Ref. 053473

Honeywell Gas Valve VK4115M - Vaillant Turboblock VCM 182/1 E - Ref. 053473

Honeywell VK4115M gas valve, with integrated V7335A modulating actuator, which regulates the flow and modulation of gas to the burner. Maximum input pressure 80 mbar, power supply 230/240V~ 50/60Hz, actuator range 15-20 mbar. It fits Vaillant boilers from the Turbomax, Thermocompact, and VCM/VMW series. Replacement requires first confirming the fault of the part through technical diagnosis, even when the boiler does not ignite or the flame does not modulate correctly.

Type of part
Gas valves
Catalogue reference
053473
Warranty
1 year
VAT included Stock · 7 units
Compatibility

Vaillant boilers compatible with reference 053473

Gas valve with reference 053473. Eight confirmed compatibilities: VCM 180/1 and VCM 182/1 E.

Proven compatibility

Boiler modelFamilyVerification
Vaillant VCM 180/1Turboblock VCMContrasted
Vaillant VCM 182/1 ETurboblock VCMContrasted
Vaillant VCM 240/1Turboblock VCMContrasted
Vaillant VCM 242/1 ETurboblock VCMContrasted
Vaillant VCM 260/1Turboblock VCMContrasted
Vaillant VCM 282/1 ETurboblock VCMContrasted
Vaillant VC 240/1VC (atmospheric block)Contrasted
Vaillant VC 242/1 EVC (atmospheric block)Contrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if the part number 053473 is the correct one for your boiler.

The part reference, model, and equipment revision must be verified against the manufacturer's documentation.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference 053473. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms that require diagnosis in the gas valve 053473

The gas valve regulates and modulates the gas flow to the burner. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The boiler does not ignite, the flame does not light up.

    Cause: The Honeywell gas valve does not open the gas flow to the burner.

    Check that there is ignition spark and normal gas pressure before replacing the gas valve.

  • 02

    The flame does not increase in power even though the boiler requests it.

    Cause: The V7335A modulating actuator does not regulate the gas flow properly.

    Check that the actuator moves when requesting more power (a slight buzzing can be heard) before replacing it.

  • 03

    The power of the boiler fluctuates, rising and falling without reason.

    Cause: The modulating actuator loses precision in flow regulation.

    Check that there is no dirt in the gas inlet or in the filter before considering the gas valve faulty.

  • 04

    The boiler locks up just when trying to ignite.

    Cause: Fault in the opening of the gas valve associated with the Honeywell assembly.

    Note the fault code of the boiler and in which phase of the cycle the lock occurs.

Vaillant fault codes that require diagnosis

CodeFaultTechnical checks
F.61Fuel valve activation errorThe gas valve cannot be actuated (coils in short circuit or without power supply) and the electronics detect a control fault; check voltage/ground at the connector, continuity of coils and wiring harness.
F.62Fuel valve disconnection delay errorThe gas valve closes with a delay or presents a leak, so the flame signal persists after the shutdown command; check the valve's tightness and ensure that ionisation drops immediately when the demand is cut.
F.27Safety shutdown: Flame simulationWith the valve closed, a flame signal is detected; an internal leak of the valve (solenoid not closing) causes false ionisation; check for valve leaks with a tightness test and rule out moisture/electronics.
F.28Start-up fault: ignition failedA faulty gas valve may not open or may not provide the minimum flow at startup, causing ignition failure; check the power supply to the valve during ignition and pressure/flow in the gas ramp.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Data sheet for the gas valve Vaillant 053473

Catalogue reference
053473
Uniclima internal SKU
VGTVCMES182
Brand
Vaillant
Type of part
Gas valves
Units in stock
7 units
Status
Refurbished
Warranty
1 year
Shipping
Delivery time shown at checkout
Return
14 days

Part data and available documentation

Contrast the label codes, PCB, and revision with the installed part; they are not necessarily equivalent references.

Manufacturer
Honeywell
Base model
VK4115M
Maximum inlet pressure
Pmax. 80 mbar
Power supply
230/240V~ 50/60Hz, 0.044A / 0.082A
Ambient temperature
-13...80°C
Modulating actuator
V7335A 2380 1, Max. 17V, Max. 250mA, Range 15...20 mbar
Before purchasing
  • The actual manufacturer of the component is Honeywell, not Vaillant. Vaillant is the brand of the boiler.
Documentation

Manuals and technical documentation

Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.

Frequently Asked Questions

Frequently asked questions about the gas valve 053473

Who manufactures the gas valve for the Vaillant Turboblock VCM 182/1 E?
Honeywell, model VK4115M; Vaillant is the brand of the boiler, not of the component.
Does this valve Ref. 053473 also work for other Vaillant models?
The valve is compatible only with the models from the 'Turboblock VCM' and 'VC (atmospheric block)' ranges listed in the compatibility table.
Does the Honeywell VK4115M valve come with a modulating actuator?
Yes, it includes an integrated actuator V7335A (max. 17V, max. 250mA, range 15-20 mbar) that regulates the gas modulation.
What is the maximum pressure that the gas valve can handle?
It accepts a maximum input pressure of 80 mbar, with a power supply of 230/240V~ 50/60Hz, according to the label.
How many models are compatible with the Honeywell VK4115M gas valve?
The valve is compatible with a total of 8 models, according to the compatibility table.
What fault codes are documented for this gas valve?
The documented fault codes are F.61, F.62, F.27, and F.28.
Entrega calculada por destino Delivery time shown at checkout
1-year warranty reviewed and tested
14-day return uninstalled parts
Technical support we verify your model
Honeywell Gas Valve VK4115M - Vaillant Turboblock VCM 182/1 E - Ref. 053473