Stock · 5 units

SIT Sigma 845 gas valve (code 0845058), with solenoid valves EV1 and EV2 at 230V~50Hz that regulate the gas flow to the burner. Maximum inlet 60 mbar, regulated outlet between 1 and 37 mbar, maximum current 165 mA. It is equivalent to the Ariston reference 65100516, used in the Genus 27 BFFI and related models. It is replaced when ignition fails or the flame does not modulate.

VAT included

Compatibility

Ariston boilers compatible with reference 65100516

Gas valve with reference 65100516. Eight confirmed compatibilities: GENUS 27 BFFI and GENUS 27 BI.

Proven compatibility

Boiler modelFamilyVerification
Ariston GENUS 27 BFFIGenusContrasted
Ariston GENUS 27 BIGenusContrasted
Ariston MICROGENUS 23 MFFIMicroGenusContrasted
Ariston MICROGENUS 27 MIMicroGenusContrasted
Ariston MGENUS 23 MFFIMicroGenus Plus / MGenusContrasted
Ariston MGENUS 27 MFFIMicroGenus Plus / MGenusContrasted
Ariston MICROGENUS PLUS 24 MFFIMicroGenus Plus / MGenusContrasted
Ariston MICROGENUS PLUS 28 MFFIMicroGenus Plus / MGenusContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if the ref. 65100516 is the part for your boiler

What determines it is not the boiler model, but the reference printed on the part you already have installed.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference 65100516. If it is not visible, do not identify the part by its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms and faults that the gas valve 65100516 resolves

The gas valve regulates and modulates the gas flow to the burner. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The boiler does not ignite: there is no flame when attempting to start.

    Cause: The solenoid valve EV1 does not open the gas supply for ignition.

    Check that the valve receives power at the EV1 connector at the moment of startup.

  • 02

    The flame ignites but does not increase in power even when you request more heat.

    Cause: The solenoid valve EV2 does not open correctly and limits the maximum gas flow.

    Measure if there is current in EV2 during the maximum power demand before changing the gas valve.

  • 03

    The boiler locks up when starting, repeatedly.

    Cause: Intermittent fault in one of the solenoid valves of the gas valve.

    Note the fault code displayed by the boiler and if the lockout occurs always at the same point in the cycle.

  • 04

    There is a smell of gas in the area of the gas valve.

    Cause: Leak in the body or in the joints of the gas valve

    Locate the leak point with a leak detector spray before deciding on the replacement.

Fault codes for Ariston that this part resolves.

CodeFaultDiagnosis and solution
E20Flame detected with the gas valve closed.The gas valve may remain stuck open or leak when the electronics have it closed, maintaining a flame. Check that there is no voltage in the coil and yet there is gas flow (manometer/analyser) and verify tightness; rule out false ionisation by checking the electrode.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Data sheet for the Ariston gas valve 65100516

Catalogue reference
65100516
Brand
Ariston
Type of part
Gas valves
Units in stock
5 units
Status
Refurbished
Warranty
1 year
Shipping
1-2 business days
Return
14 days

Data read on the part and in the manufacturer's documentation

What we have not been able to verify does not appear here.

Manufacturer
SIT
SIT Code
0845058
Model
845 Sigma
Ariston equivalence
Ref. 65100516, used in Genus 27 BFFI and other Ariston models.
EV1 voltage
230V~50Hz, 9.2 VA class B
EV2 voltage
230V~50Hz, 2.8 VA class J
Maximum current
165 mA
Ambient temperature
0/60°C
Maximum inlet pressure (Pi max)
60 mbar
Outlet pressure (Po)
1-37 mbar
Coil marking
3H22
Before purchasing
  • The actual manufacturer of the component is SIT, not Ariston. Ariston is the brand of the boiler.
Frequently Asked Questions

Frequently asked questions about the gas valve 65100516

Who manufactures the gas valve for the Ariston Genus 27 BFFI Plus?
SIT (fault code 0845058, model 845 Sigma); Ariston is the brand of the boiler, not of the component.
Does this valve Ref. 65100516 also work for an Ariston Uno 23 MFFI?
Yes, the Uno 23 MFFI is on the list of compatible boilers along with the Intesa, Microcombi, Microgenus, and Excalibur ranges.
What voltage do the solenoid valves of this SIT Sigma 845 valve operate at?
EV1 and EV2 operate at 230V~50Hz, with 9.2 VA and 2.8 VA respectively, according to the label.
What is the maximum current of the gas valve used in the Ariston Genus 27 BFFI Plus?
165 mA, according to the label.
When should this valve be replaced in an Ariston boiler from the Microgenus or Intesa range?
When the ignition fails or the flame does not modulate correctly.