SIT Sigma 845 Gas Valve - Ariston Genus 27 BFFI - Ref. 65100516
SIT Sigma 845 gas valve (code 0845058), with solenoid valves EV1 and EV2 at 230V~50Hz that regulate the gas flow to the burner. Maximum inlet 60 mbar, regulated outlet between 1 and 37 mbar, maximum current 165 mA. It is equivalent to the Ariston reference 65100516, used in the Genus 27 BFFI and related models. It is replaced when ignition fails or the flame does not modulate.
VAT included
Consult via WhatsAppAriston boilers compatible with reference 65100516
Gas valve with reference 65100516. Eight confirmed compatibilities: GENUS 27 BFFI and GENUS 27 BI.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Ariston GENUS 27 BFFI | Genus | Contrasted |
| Ariston GENUS 27 BI | Genus | Contrasted |
| Ariston MICROGENUS 23 MFFI | MicroGenus | Contrasted |
| Ariston MICROGENUS 27 MI | MicroGenus | Contrasted |
| Ariston MGENUS 23 MFFI | MicroGenus Plus / MGenus | Contrasted |
| Ariston MGENUS 27 MFFI | MicroGenus Plus / MGenus | Contrasted |
| Ariston MICROGENUS PLUS 24 MFFI | MicroGenus Plus / MGenus | Contrasted |
| Ariston MICROGENUS PLUS 28 MFFI | MicroGenus Plus / MGenus | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if the ref. 65100516 is the part for your boiler
What determines it is not the boiler model, but the reference printed on the part you already have installed.
- Find the reference printed on the installed part and check whether it matches the catalogue reference 65100516. If it is not visible, do not identify the part by its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms and faults that the gas valve 65100516 resolves
The gas valve regulates and modulates the gas flow to the burner. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The boiler does not ignite: there is no flame when attempting to start.
Cause: The solenoid valve EV1 does not open the gas supply for ignition.
Check that the valve receives power at the EV1 connector at the moment of startup.
- 02
The flame ignites but does not increase in power even when you request more heat.
Cause: The solenoid valve EV2 does not open correctly and limits the maximum gas flow.
Measure if there is current in EV2 during the maximum power demand before changing the gas valve.
- 03
The boiler locks up when starting, repeatedly.
Cause: Intermittent fault in one of the solenoid valves of the gas valve.
Note the fault code displayed by the boiler and if the lockout occurs always at the same point in the cycle.
- 04
There is a smell of gas in the area of the gas valve.
Cause: Leak in the body or in the joints of the gas valve
Locate the leak point with a leak detector spray before deciding on the replacement.
Fault codes for Ariston that this part resolves.
| Code | Fault | Diagnosis and solution |
|---|---|---|
| E20 | Flame detected with the gas valve closed. | The gas valve may remain stuck open or leak when the electronics have it closed, maintaining a flame. Check that there is no voltage in the coil and yet there is gas flow (manometer/analyser) and verify tightness; rule out false ionisation by checking the electrode. |
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Data sheet for the Ariston gas valve 65100516
- Catalogue reference
- 65100516
- Brand
- Ariston
- Type of part
- Gas valves
- Units in stock
- 5 units
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- 1-2 business days
- Return
- 14 days
Data read on the part and in the manufacturer's documentation
What we have not been able to verify does not appear here.
- Manufacturer
- SIT
- SIT Code
- 0845058
- Model
- 845 Sigma
- Ariston equivalence
- Ref. 65100516, used in Genus 27 BFFI and other Ariston models.
- EV1 voltage
- 230V~50Hz, 9.2 VA class B
- EV2 voltage
- 230V~50Hz, 2.8 VA class J
- Maximum current
- 165 mA
- Ambient temperature
- 0/60°C
- Maximum inlet pressure (Pi max)
- 60 mbar
- Outlet pressure (Po)
- 1-37 mbar
- Coil marking
- 3H22
- The actual manufacturer of the component is SIT, not Ariston. Ariston is the brand of the boiler.