Vaillant Turboblock VCM 180/1 X PCB Ref. 711450

Vaillant Turboblock VCM 180/1 X PCB Ref. 711450

If your boiler does not start, locks out, or shows erratic operation, a technical diagnosis must confirm if you need the Vaillant Turboblock VCM 180/1 X PCB, reference 711450. This part is responsible for controlling the ignition, burner modulation, pump, and safety features of the boiler. When it fails, you may experience faults such as F.61, F.62, F.63, F.64, or F.65. It is compatible with models from the Turboblock VCM range, such as the VCM 182/1 E, VCM 242/1 E, and VCM 180/1, among others. A technician must confirm through diagnosis if it needs to be replaced if you notice these symptoms to restore the operation of your boiler.

Catalogue reference
130438
Warranty
1 year
VAT included Stock · 1 unit
Compatibility

Vaillant boilers compatible with reference 130438

PCB with reference 130438. Eight confirmed compatibilities: VCM 182/1 E and VCM 242/1 E.

Proven compatibility

Boiler modelFamilyVerification
Vaillant VCM 182/1 ETurboblock VCM (series /1 E)Contrasted
Vaillant VCM 242/1 ETurboblock VCM (series /1 E)Contrasted
Vaillant VCM 282/1 ETurboblock VCM (series /1 E)Contrasted
Vaillant VCM 240/1Turboblock VCM (series /1 E)Contrasted
Vaillant VCM 260/1Turboblock VCM (series /1 E)Contrasted
Vaillant VCM 180/1Turboblock VCM (series /1 E)Contrasted
Vaillant VC 240/1VC (series /1 E)Contrasted
Vaillant VC 242/1 EVC (series /1 E)Contrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. 130438 is the part for your boiler

The part reference, model, and equipment revision must be verified against the manufacturer's documentation.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference 130438. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms that require diagnosis on the PCB 130438

The PCB controls the ignition, modulation, and safety features of the boiler. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The boiler does not ignite in any mode: neither heating nor domestic hot water.

    Cause: The central PCB does not send the ignition signal to the gas valve or the burner.

    Check if resetting the panel solves the problem and verify that there are no visible blown fuses before replacing the PCB.

  • 02

    The panel displays a fault code that disappears when turning it off and on, but reappears after a while.

    Cause: It is typical for a PCB to start failing intermittently before completely stopping functioning.

    Keep a record of when the fault code appears: if it coincides with cold start or with the use of domestic hot water, it helps to confirm the diagnosis.

  • 03

    The remote control or the room thermostat occasionally loses connection with the boiler.

    Cause: The communication module integrated into the PCB is intermittently failing.

    Bring the remote closer to the boiler and check its batteries before blaming the PCB.

  • 04

    The fault indicator remains lit continuously and the reset does not turn it off.

    Cause: The PCB detects an internal fault and keeps it locked until it is repaired or replaced.

    Try the reset by holding it down for several seconds, not with a quick touch, before considering the PCB lost.

Vaillant fault codes that require diagnosis

CodeFaultTechnical checks
F.61Gas valve activation error.The relay/output stage of the PCB (auxiliary/main) does not correctly switch the gas valve. Check the power supply to the valve at the terminals, continuity of the harness, and if everything is correct, replace the PCB to confirm.
F.62Delay in gas valve disconnection.This symptom may be related to the part, but it does not confirm that it is faulty. A technician must check the equipment and its inspection according to the manual before deciding on a repair or replacement.
F.63Fault: EEPROM (electronics).Corruption/defect of the EEPROM memory on the PCB. Check resets and parameters; the standard check is to replace the board with a new or programmed one to rule out the fault.
F.64Fault in the electronics/NTC.Fault in the measurement/ADC stage or sensor power supply on the PCB. Check NTC and wiring; if the sensors measure correctly but the fault code persists, the cause is the PCB.
F.65Fault: electronics temperature too high.The thermal sensor on the PCB detects overheating or the PCB itself is damaged. Check ventilation/location and temperatures; if they are normal and the error repeats, replace the PCB.
F.67Fault: electronics/flame (flame signal not plausible).The detection/ionization stage on the PCB delivers an incoherent signal. Check the electrode, cable, and polarity; if everything is correct, the fault is in the PCB.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Data sheet for the Vaillant 130438 PCB.

Catalogue reference
130438
Uniclima internal SKU
MEVCMES180X
Brand
Vaillant
Type of part
PCBs (control boards)
Units in stock
1 unit
Status
Refurbished
Warranty
1 year
Shipping
Delivery time shown at checkout
Return
14 days

Part data and available documentation

Contrast the label codes, PCB, and revision with the installed part; they are not necessarily equivalent references.

Manufacturer
Vaillant
Silkscreen reference
711450
Silkscreen secondary code
190
Welding face code
733991 03A
Documentation

Manuals and technical documentation

Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.

Frequently Asked Questions

Frequently asked questions about the PCB 130438

Is the Vaillant Turboblock VCM 180/1 X PCB (Ref. 711450) an original part?
Yes, the manufacturer listed on the label is Vaillant, which guarantees that it is an original part.
For which boiler models is this PCB compatible?
The PCB is compatible with the following models: VCM 182/1 E, VCM 242/1 E, VCM 282/1 E, VCM 240/1, VCM 260/1, VCM 180/1, VC 240/1, and VC 242/1 E.
How many models are compatible with this PCB?
A total of 8 models are compatible with the Vaillant Turboblock VCM 180/1 X PCB Ref. 711450.
What fault codes are documented for this PCB?
The documented fault codes are: F.61, F.62, F.63, F.64, F.65, and F.67.
Does this PCB Ref. 711450 work for a VCM 180/1?
Yes, the VCM 180/1 is on the list of boilers compatible with this PCB.
What fault symptoms may indicate a problem with this PCB?
The fault symptoms may include fault codes such as F.61, F.62, F.63, F.64, F.65, and F.67.

Spare parts related to Vaillant Turboblock VCM (series /1 E)

Entrega calculada por destino Delivery time shown at checkout
1-year warranty reviewed and tested
14-day return uninstalled parts
Technical support we verify your model
Vaillant Turboblock VCM 180/1 X PCB Ref. 711450