PCB for Vaillant boilers from the VC and VCW series. The PCB itself has the Vaillant logo and the code 711450 printed on it, along with connectors X500, X501, X503, and X504. Three independent external sources identify this PCB with the commercial reference 130451. It is replaced when the original electronic module of the boiler fails.

VAT included

Compatibility

Vaillant boilers compatible with reference 130451

PCB with reference 130451. Eight confirmed compatibilities: VC 112 E and VC 142 E.

Proven compatibility

Boiler modelFamilyVerification
Vaillant VC 112 EThermocompact VC (E)Contrasted
Vaillant VC 142 EThermocompact VC (E)Contrasted
Vaillant VC 182 EThermocompact VC (E)Contrasted
Vaillant VC 242 EThermocompact VC (E)Contrasted
Vaillant VC 282 EThermocompact VC (E)Contrasted
Vaillant VCW 182 EThermocompact VCW (E)Contrasted
Vaillant VCW 242 EThermocompact VCW (E)Contrasted
Vaillant VCW 282 EThermocompact VCW (E)Contrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. 130451 is the part for your boiler

What determines it is not the boiler model, but the reference printed on the part you already have installed.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference 130451. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms and faults that the PCB 130451 resolves.

The PCB controls the ignition, modulation, and safety features of the boiler. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The boiler is completely off, with no lights or sounds of any kind.

    Cause: The PCB distributes power to the fan, pump, and gas valve; without it, nothing starts.

    Check the fuse on the PCB and ensure that the main switch of the boiler is actually supplying power before replacing it.

  • 02

    A fixed fault code appears on the screen and no button removes it.

    Cause: The microprocessor on the PCB blocks the safety fault, which is why it cannot be reset from the outside.

    Check the manual to see which component is associated with that specific fault code and rule it out before purchasing the PCB.

  • 03

    The boiler turns on, heats for a few minutes, and then shuts off repeatedly.

    Cause: An intermittent fault in the PCB interrupts the flame maintenance command even though the rest of the circuit is fine.

    Check if the shutdown always occurs after the same amount of time: it helps to distinguish a PCB fault from a temperature sensor fault.

  • 04

    You change the temperature from the control and the boiler does not respond.

    Cause: The temperature command goes through the control stage of the PCB before reaching the burner.

    Try changing the temperature directly on the boiler's panel, without using the remote, to isolate whether the problem is with the PCB or the remote.

Fault codes from Vaillant that this part resolves.

CodeFaultDiagnosis and solution
F.33Pressure switch faultThe auxiliary air control board (130451) manages the reading/switching of the pressure switch; if it is faulty, the equipment does not recognize the change of state of the pressure switch and triggers F.33. Check in diagnostics (e.g., D.24) that the state of the pressure switch does not change when actuated/jumpered and that there is continuity to this board; if it does not change, the 130451 is defective.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Data sheet for the Vaillant 130451 PCB.

Catalogue reference
130451
Brand
Vaillant
Type of part
PCBs (control boards)
Units in stock
5 units
Status
Refurbished
Warranty
1 year
Shipping
1-2 business days
Return
14 days

Data read on the part and in the manufacturer's documentation

What we have not been able to verify does not appear here.

Code printed on PCB (next to connectors X500/X501/X503/X504)
711450
Commercial reference
130451
Documentation

Manuals and technical documentation

Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.

Frequently Asked Questions

Frequently asked questions about the PCB 130451

Is it an original Vaillant PCB for the VC 242 E?
Yes, it has the Vaillant logo printed on the PCB.
Is this PCB suitable for a Vaillant VCW 242 E?
Yes, the VCW 242 E is among the compatible models.
Is this PCB suitable for a Vaillant VC 112 E?
Yes, the VC 112 E is on the list of compatible boilers.
What connectors does the PCB of the Vaillant VC 242 E have?
According to the PCB itself, connectors X500, X501, X503, and X504.
Delivery 1–2 daysworking days, mainland Spain
1-year warrantyreviewed and tested
14-day returnuninstalled parts
Technical supportwe verify your model