In Vaillant boilers from the VC/VCW E range, the pressure switch with fault code 605.99030 is a component that checks the air or water pressure and authorizes the operation of the boiler. If this part fails, you will notice that the boiler does not start or gets locked, even when the actual pressure is adequate. This pressure switch is compatible with models such as VC 112 E, VC 182 E, VC 242 E, VCW 182 E, VCW 242 E, and VCW 282 E, among others. It is recommended to replace it when there are starting failures or system lockouts.

VAT included

Compatibility

Vaillant boilers compatible with reference 050518

Pressure switch with reference 050518. Six confirmed compatibilities: VC 112 E and VC 182 E.

Proven compatibility

Boiler modelFamilyVerification
Vaillant VC 112 ETHERMOcompact (VC ... E)Contrasted
Vaillant VC 182 ETHERMOcompact (VC ... E)Contrasted
Vaillant VC 242 ETHERMOcompact (VC ... E)Contrasted
Vaillant VCW 182 ECOMBIcompact (VCW ... E)Contrasted
Vaillant VCW 242 ECOMBIcompact (VCW ... E)Contrasted
Vaillant VCW 282 ECOMBIcompact (VCW ... E)Contrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. 050518 is the part for your boiler

What determines it is not the boiler model, but the reference printed on the part you already have installed.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference 050518. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms and faults that the pressure switch 050518 resolves.

The pressure switch controls the air or water pressure to authorize operation. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The boiler locks out with a fault warning related to air pressure.

    Cause: The pressure switch does not close the contact as it should, and the control board thinks there is not enough draft.

    Check that the silicone tube going from the pressure switch to the flue is not detached, cracked, or filled with water.

  • 02

    The burner does not start even though the fan is working properly.

    Cause: If the pressure switch does not close the contact, the gas valve does not receive the command to open for safety reasons.

    Check the electrical connections of the pressure switch; a loose wire can cause the same symptom as a faulty component.

  • 03

    The boiler stops by itself from time to time, without a clear pattern, and it needs to be reset.

    Cause: A faulty connection in the pressure switch can cause intermittent cuts, even if the air pressure is correct most of the time.

    Gently move the pressure switch wires while the boiler is running to see if the fault recurs; this would indicate a loose connection rather than a break.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Vaillant 050518 pressure switch datasheet

Catalogue reference
050518
Brand
Vaillant
Type of part
Pressure switches
Units in stock
5 units
Status
Refurbished
Warranty
1 year
Shipping
1-2 business days
Return
14 days

Data read on the part and in the manufacturer's documentation

What we have not been able to verify does not appear here.

Component code
605.99030
Switching pressure
45/28 Pa
Electrical contact data
0.2(0.1) A / 30V~ [label text not entirely clear, possible voltage figure cut off]
Batch
050547
Certification
VDE-Reg-Nr. 2421
Documentation

Manuals and technical documentation

Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.

Frequently Asked Questions

Frequently asked questions about the pressure switch 050518

Does this pressure switch 605.99030 (Ref. 050518) fit a Vaillant VCW 242 E?
Yes, the VCW 242 E is on the confirmed list of compatible boilers, along with VC 112 E, VC 182 E, VC 242 E, VCW 182 E, and VCW 282 E.
What fault does replacing this pressure switch in a Vaillant VC 242 E resolve?
It is replaced when the boiler locks out due to a pressure detection fault.
At what pressure does the pressure switch Ref. 050518 switch?
Its switching point is 45/28 Pa, according to the label.