CEME PB 6412/VAR Pressure Switch For Baxi Roca Neobit 24/24F Boiler - Ref. 125995169
Pressure switch manufactured by CEME S.p.A. (Carugate, Italy), manufacturer code PB 6412/VAR, installed in Baxi Roca boilers of the Neobit, Novamax, Novanox, Platinum, Victoria Plus, Bios, and Altais series. It operates within a pressure range of 0.2 to 2 bar, with a maximum of 4.5 bar, and cuts the contact if the pressure is incorrect. It is replaced when the boiler locks due to a pressure fault.
VAT included
Consult via WhatsAppBaxi Roca boilers compatible with reference 125995169
Pressure switch with reference 125995169. Three confirmed compatibilities: Neobit S 24/24 F and Neobit Plus 24/24 F.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Baxi Roca Neobit S 24/24 F | Neobit | Contrasted |
| Baxi Roca Neobit Plus 24/24 F | Neobit | Contrasted |
| Baxi Roca Novanox 24/24 F | Novanox | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if ref. 125995169 is the part for your boiler
What determines it is not the boiler model, but the reference printed on the part you already have installed.
- Find the reference printed on the installed part and check whether it matches the catalogue reference 125995169. If it is not visible, do not identify the part from its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms and faults that the pressure switch 125995169 resolves.
The pressure switch controls the air or water pressure to authorize operation. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The boiler locks out with a pressure fault even though it is properly bled and has normal pressure.
Cause: The pressure switch is not closing properly, so the PCB thinks there is no pressure even though there is.
Check the actual pressure on the boiler's manometer and bleed if necessary, before declaring the pressure switch faulty.
- 02
The burner does not ignite; it remains waiting even though the pump or the fan can be heard operating.
Cause: Without the pressure switch's closed contact, the control board does not give the final ignition command for safety reasons.
Check that the tubes connecting the pressure switch to the circuit are not bent, crushed, or blocked.
- 03
The boiler turns on and off several times in a row, as if it is losing contact.
Cause: A worn or dirty contact inside the pressure switch can open and close intermittently without relation to the actual pressure.
Gently tap the pressure switch casing while the boiler is running; if the fault appears or disappears, it indicates a loose connection.
- 04
The pressure fault appears and disappears on its own, without any intervention on the circuit.
Cause: A pressure switch with a worn diaphragm can give incorrect intermittent readings that correct themselves.
Keep a record of when the fault occurs (time, if the pump has just started, etc.) to confirm the pattern before replacing it.
Fault codes for Baxi Roca that this part resolves.
| Code | Fault | Diagnosis and solution |
|---|---|---|
| E10 | The hydraulic pressure switch does not authorize operation (low water pressure). | If the water pressure switch/sensor is faulty (open contacts, erratic reading, or defective wiring), the boiler interprets it as a lack of pressure and locks with E10; check that the pressure gauge reads ~1–1.5 bar and verify the continuity/signal of the pressure switch at the PCB connector. |
| 60 | Lack of water in the heating circuit (insufficient pressure) – indicated by LED 60 on Neobit S. | A water pressure switch/sensor that does not switch or gives an out-of-range signal causes the electronics to detect a lack of pressure and illuminate LED 60; confirm actual pressure on the pressure gauge and measure continuity/signal of the hydraulic pressure switch. |
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Datasheet for Baxi Roca pressure switch 125995169
- Catalogue reference
- 125995169
- Brand
- Baxi Roca
- Type of part
- Pressure switches
- Units in stock
- 1 unit
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- 1-2 business days
- Return
- 14 days
Data read on the part and in the manufacturer's documentation
What we have not been able to verify does not appear here.
- Manufacturer
- CEME S.p.A., Carugate (MI), Italy
- Component code
- TYPE PB 6412/VAR
- Pressure range
- 0.2 – 2 bar
- Maximum pressure
- 4.5 bar
- NC Contact
- 15A/250V~
- Contact NO
- 9A/250V~
- Ambient temperature
- TA:100°C (UL 90°C max.)
- The actual manufacturer of this part is CEME (Italy), different from Baxi Roca, which is the brand of the boiler. It is not an original Baxi Roca spare part.
Manuals and technical documentation
Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.
- Baxi Roca Neobit S 24/24 F Manual (PDF)Document © Baxi Roca, provided as a technical reference.