Air Pressure Switch Heatline / Demrad / Vaillant Ref. 3003200136

Air Pressure Switch Heatline / Demrad / Vaillant Ref. 3003200136

Stock · 1 unit

The boilers from the Heatline, Demrad, and Vaillant ranges use the air pressure switch 3003200136. This part checks the air pressure, ensuring that the boiler operates correctly. If the pressure switch fails, the boiler may not start or may lock out, even if the pressure is correct. It is compatible with models such as the Heatline C24, C28, and the Vaillant TurboMax, among others. It should be replaced when symptoms of lockout or failed start occur in the system.

VAT included

Compatibility

Airsol boilers compatible with reference 3003200136

Pressure switch with reference 3003200136. 16 verified compatibilities: Aden and Atron.

Proven compatibility

Boiler modelFamilyVerification
Airsol AdenDemradContrasted
Airsol AtronDemradContrasted
Airsol KalistoDemradContrasted
Airsol SolarisDemradContrasted
Airsol C24HeatlineContrasted
Airsol C28HeatlineContrasted
Airsol Compact C24HeatlineContrasted
Airsol Compact C28HeatlineContrasted
Airsol Compact S20SHeatlineContrasted
Airsol Compact S24SHeatlineContrasted
Airsol Compact S30SHeatlineContrasted
Airsol S24HeatlineContrasted
Airsol S30HeatlineContrasted
Airsol Vizo 24HeatlineContrasted
Airsal TurboMaxVaillantContrasted
Airsol TurboTECVaillantContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if the reference 3003200136 is the part for your boiler

What determines it is not the boiler model, but the reference printed on the part you already have installed.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference 3003200136. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms and faults that the pressure switch 3003200136 resolves.

The pressure switch controls the air or water pressure to authorize operation. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The boiler sometimes ignites and other times it locks up as soon as the fan starts.

    Cause: The pressure switch does not correctly detect the depression generated by the fan before allowing the burner to ignite.

    Check the air intake filter or grille and the flue outlet for any partial obstruction before replacing the part.

  • 02

    A ventilation fault appears on the display as soon as the command to turn on the boiler is given.

    Cause: The safety circuit is activated because the pressure switch does not confirm that there is sufficient draft.

    Disconnect and gently blow through the pressure switch connection tubes to rule out any blockage from dust or condensation.

  • 03

    The ignitions are intermittent: sometimes it lights on the first try and other times it takes several attempts.

    Cause: A pressure switch at the limit of its travel responds irregularly to small pressure variations from the extractor.

    Check that the fan is not making any strange noises and that it doesn't take long to gain speed, to rule out that the problem is coming from there and not from the pressure switch.

  • 04

    The ventilation blockage occurs mainly when the boiler has been idle for a while or when it's cold.

    Cause: A worn pressure switch loses accuracy and has more difficulty activating during cold starts.

    Record whether the fault occurs only when cold or also when the boiler is hot, to determine if it is the pressure switch or the flue system.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Data sheet for pressure switch Airsol 3003200136

Catalogue reference
3003200136
Brand
Airsol
Type of part
Pressure switches
Units in stock
1 unit
Status
Refurbished
Warranty
1 year
Shipping
1-2 business days
Return
14 days

Data read on the part and in the manufacturer's documentation

What we have not been able to verify does not appear here.

Model code
605.99644
Spare part reference
3003200136
Switching pressure
105/90 Pa
Differential / time
0.2(0.1)/30~
Batch code
ZGJDED
Frequently Asked Questions

Frequently asked questions about the pressure switch 3003200136

At what pressure does the pressure switch of the Heatline C24 switch?
At 105/90 Pa, with a switching time of 0.2(0.1)/30~, according to the part label.
What fault indicates that this pressure switch needs to be replaced in a Demrad Aden?
That the boiler does not ignite, gets blocked due to a ventilation fault, or the ignitions are intermittent.
Is this pressure switch compatible with a Vaillant TurboMax?
Yes, the Vaillant TurboMax is on the list of boilers compatible with this part, Ref. 3003200136.