Circulator Pump Boiler Baxi Roca Victoria 24/24F
Circulating pump for Baxi Roca Victoria 24/24F boilers, also used in Neobits, Novanox, and Platinum Max 28/28F. It circulates water in the heating circuit. According to the label: 230V, 50Hz, 75W, 0.34A, capacitor 2.0 µF, IP44, Class H, up to 0.3 MPa. It is replaced when the pump does not start, makes noise, leaks, or the boiler loses circulation.
VAT included
Consult via WhatsAppBaxi Roca boilers compatible with reference 7801354
Circulating pump with reference 7801354. Four confirmed compatibilities: VICTORIA 24/24 and VICTORIA 24/24 F.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Baxi Roca VICTORIA 24/24 | Victoria | Contrasted |
| Baxi Roca VICTORIA 24/24 F | Victoria | Contrasted |
| Baxi Roca NEOBIT S 24/24 | Neobit | Contrasted |
| Baxi Roca NEOBIT S 24/24 F | Neobit | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if ref. 7801354 is the part for your boiler
What determines it is not the boiler model, but the reference printed on the part you already have installed.
- Find the reference printed on the installed part and check whether it matches the catalogue reference 7801354. If it is not visible, do not identify the part from its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms and faults that the circulation pump 7801354 resolves.
The circulation pump circulates the water in the heating circuit. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The pump does not start when the boiler calls for heating.
Cause: The start capacitor or the motor winding has failed and the rotor does not receive the impulse to turn.
Try turning the shaft with a flat screwdriver in the front slot of the motor; if it is stuck, try to free it before replacing the pump.
- 02
There is noticeable vibration or rough noise while it is operating.
Cause: The rotor bearings are worn out or there is limescale embedded in the impeller that is causing it to be unbalanced.
Check if the circuit pressure is correct and bleed the air before declaring the pump faulty.
- 03
Water is leaking from the area of the shaft, between the motor and the body of the pump.
Cause: The mechanical seal that separates the wet part from the electrical part has worn out and no longer seals.
Don't confuse it with condensation: dry the area, let the boiler run for a while, and check if water reappears right at the axis.
- 04
The radiators take a long time to heat up or remain lukewarm.
Cause: The pump is running but does not reach the necessary discharge pressure, due to wear on the impeller or air in the circuit.
Bleed the radiators and the pump's own bleeder before declaring the part as exhausted.
Fault codes for Baxi Roca that this part resolves.
| Code | Fault | Diagnosis and solution |
|---|---|---|
| E25 | Activation of the safety device due to probable pump blockage. | The seizing or failure of the pump prevents circulation and the primary circuit overheats quickly; check the 230 V supply to the pump and unblock/inspect the shaft from the front cap and the filter/return. |
| E26 | Activation of the safety device due to probable pump blockage. | With the pump blocked, the flow exceeds the setpoint due to lack of flow (overtemperature); check that the pump rotates freely and receives voltage, bleed air, and inspect for obstructions in the circuit/filter. |
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Data sheet for the Baxi Roca circulator pump 7801354
- Catalogue reference
- 7801354
- Brand
- Baxi Roca
- Type of part
- Pumps
- Units in stock
- 1 unit
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- 1-2 business days
- Return
- 14 days
Data read on the part and in the manufacturer's documentation
What we have not been able to verify does not appear here.
- Voltage
- 230V~ 50Hz
- Current
- 0.34 A
- Power
- 75 W
- Condenser
- 2.0 µF
- IP Protection
- IP44
- Insulation class
- Class H
- Maximum pressure
- 0.3 MPa
Manuals and technical documentation
Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.
- Baxi Roca Neobit S 24/24 F Manual (PDF)Document © Baxi Roca, provided as a technical reference.