Vaillant PCB VC/VCM/VU/VUW 142-282

Vaillant PCB VC/VCM/VU/VUW 142-282

If your boiler does not start, locks out, or exhibits erratic behavior, a technical diagnosis must confirm if you need the Vaillant VC/VCM/VU/VUW 142-282 PCB. This part controls the ignition, burner modulation, pump, and safety features of the boiler. When it fails, you may see fault codes such as F.61, F.62, F.63, F.64, or F.65. It is compatible with several models, including the VCM 182/1 E, VCM 242/1 E, VCM 282/1 E, and VC 240/1, among others. Its replacement is necessary when these operational issues occur.

Catalogue reference
130438
Warranty
1 year
VAT included Stock · 3 units
Compatibility

Vaillant boilers compatible with reference 130438

PCB with reference 130438. Eight confirmed compatibilities: VCM 182/1 E and VCM 242/1 E.

Proven compatibility

Boiler modelFamilyVerification
Vaillant VCM 182/1 ETurboblock VCM (series /1 E)Contrasted
Vaillant VCM 242/1 ETurboblock VCM (series /1 E)Contrasted
Vaillant VCM 282/1 ETurboblock VCM (series /1 E)Contrasted
Vaillant VCM 240/1Turboblock VCM (series /1 E)Contrasted
Vaillant VCM 260/1Turboblock VCM (series /1 E)Contrasted
Vaillant VCM 180/1Turboblock VCM (series /1 E)Contrasted
Vaillant VC 240/1VC (series /1 E)Contrasted
Vaillant VC 242/1 EVC (series /1 E)Contrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. 130438 is the part for your boiler

The part reference, model, and equipment revision must be verified against the manufacturer's documentation.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference 130438. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms that require diagnosis on the PCB 130438

The PCB controls the ignition, modulation, and safety features of the boiler. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The boiler does not start: it does not attempt to ignite.

    Cause: Without the PCB, the gas valve opening and the fan startup are not triggered.

    Check that the fan spins freely and that there is voltage at the terminal block of the PCB; if nothing moves, suspect the fuse or the power supply.

  • 02

    The display shows a different fault code every few minutes.

    Cause: If the microprocessor on the PCB fails, it can give erratic readings from several sensors at once.

    Disconnect the boiler for a couple of minutes and note if the fault code repeats or changes each time.

  • 03

    The circulation pump never stops, even with the boiler turned off.

    Cause: The PCB controls the relay of the pump, and if it gets stuck, the pump keeps running.

    Check that it is not a post-circulation adjustment activated in the programmer before considering the PCB.

  • 04

    The remote control or the modulating thermostat is not communicating: the boiler is not receiving settings.

    Cause: The communication with the thermostat is on the PCB, and if it fails, the boiler operates with default values.

    Check the cable and the terminals of the communication bus on the PCB before replacing it.

Vaillant fault codes that require diagnosis

CodeFaultTechnical checks
F.61Gas valve activation error.The relay/output stage of the PCB (auxiliary/main) does not correctly switch the gas valve. Check the power supply to the valve at the terminals, continuity of the harness, and if everything is correct, replace the PCB to confirm.
F.62Delay in gas valve disconnection.This symptom may be related to the part, but it does not confirm that it is faulty. A technician must check the equipment and its inspection according to the manual before deciding on a repair or replacement.
F.63Fault: EEPROM (electronics).Corruption/defect of the EEPROM memory on the PCB. Check resets and parameters; the standard check is to replace the board with a new or programmed one to rule out the fault.
F.64Fault in the electronics/NTC.Fault in the measurement/ADC stage or sensor power supply on the PCB. Check NTC and wiring; if the sensors measure correctly but the fault code persists, the cause is the PCB.
F.65Fault: electronics temperature too high.The thermal sensor on the PCB detects overheating or the PCB itself is damaged. Check ventilation/location and temperatures; if they are normal and the error repeats, replace the PCB.
F.67Fault: electronics/flame (flame signal not plausible).The detection/ionization stage on the PCB delivers an incoherent signal. Check the electrode, cable, and polarity; if everything is correct, the fault is in the PCB.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Data sheet for the Vaillant 130438 PCB.

Catalogue reference
130438
Uniclima internal SKU
PATVCM242
Brand
Vaillant
Type of part
PCBs (control boards)
Units in stock
3 units
Status
Refurbished
Warranty
1 year
Shipping
Delivery time shown at checkout
Return
14 days

Part data and available documentation

Contrast the label codes, PCB, and revision with the installed part; they are not necessarily equivalent references.

manufacturer of the main chip
Vaillant
Documentation

Manuals and technical documentation

Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.

Frequently Asked Questions

Frequently asked questions about the PCB 130438

Is this Vaillant VC/VCM/VU/VUW 142-282 PCB original?
The main chip, a 40-pin DIP integrated circuit, clearly bears the Vaillant logo and name.
How many models is this PCB compatible with?
The PCB is compatible with a total of 8 models from the VCM and VC ranges.
Does this PCB work for the model VCM 182/1 E?
Yes, the model VCM 182/1 E is on the list of compatible models.
Is this PCB compatible with the model VC 240/1?
Yes, the model VC 240/1 is on the list of compatible models.
What fault codes are documented for this PCB?
The documented fault codes are F.61, F.62, F.63, F.64, F.65, and F.67.
What is the reference for this PCB?
PATVCM242 is Uniclima’s internal SKU for locating this listing. To confirm compatibility, check the manufacturer’s reference and the exact appliance model.

Spare parts related to Vaillant Turboblock VCM (series /1 E)

Entrega calculada por destino Delivery time shown at checkout
1-year warranty reviewed and tested
14-day return uninstalled parts
Technical support we verify your model
Vaillant PCB VC/VCM/VU/VUW 142-282