Junkers Cerastar Gas Valve ZWN24-7MFA23 SIT Ref. 8747003700
RefurbishedJunkersGas valvesSIT

Junkers Cerastar Gas Valve ZWN24-7MFA23 SIT Ref. 8747003700

65 €VAT includedOUT OF STOCK

SIT gas valve (model 845 Sigma) for Junkers Cerastar boilers ZWN24-7MFA23 and related models. It regulates the gas flow to the burner through two solenoid valves (EV1 and EV2) of 24 V~. Maximum inlet pressure 60 mbar, maximum current 165 mA. It is replaced when the boiler fails to ignite the burner or locks due to a gas supply fault.

Compatibility

Junkers boilers compatible with reference 8747003700

Gas valve with reference 8747003700. 31 verified compatibilities: ZWC 24/28-1 MFA and ZWC 24/28-1 MFK.

Proven compatibility

Boiler modelFamilyVerification
Junkers ZWC 24/28-1 MFACeraclass Excellence / Comfort (ZWC)Contrasted
Junkers ZWC 24/28-1 MFKCeraclass Excellence / Comfort (ZWC)Contrasted
Junkers ZWC 24/28-3 MFACeraclass Excellence / Comfort (ZWC)Contrasted
Junkers ZWC 24/28-3 MFKCeraclass Excellence / Comfort (ZWC)Contrasted
Junkers ZWC 24-1 MF2ACeraclass Excellence / Comfort (ZWC)Contrasted
Junkers ZWC 24-1 MF2KCeraclass Excellence / Comfort (ZWC)Contrasted
Junkers ZWC 28-1 MF2ACeraclass Excellence / Comfort (ZWC)Contrasted
Junkers ZWC 28-1 MF2KCeraclass Excellence / Comfort (ZWC)Contrasted
Junkers ZWC 28/32-1 MFACeraclass Excellence / Comfort (ZWC)Contrasted
Junkers ZWC 30/30-3 MFACeraclass Excellence / Comfort (ZWC)Contrasted
Junkers ZWC 35/35-3 MFACeraclass Excellence / Comfort (ZWC)Contrasted
Junkers ZSC 24-3 MFACeraclass Excellence (ZSC - heating only)Contrasted
Junkers ZSC 24-3 MFKCeraclass Excellence (ZSC - heating only)Contrasted
Junkers ZSC 28-3 MFKCeraclass Excellence (ZSC - heating only)Contrasted
Junkers ZSC 30-3 MFACeraclass Excellence (ZSC - heating only)Contrasted
Junkers ZSC 35-3 MFACeraclass Excellence (ZSC - heating only)Contrasted
Junkers ZC 24-1 MFACerastar / Ceraclass (ZC - heating only)Contrasted
Junkers ZC 24-1 MFKCerastar / Ceraclass (ZC - heating only)Contrasted
Junkers ZC 24-1 MF2ACerastar / Ceraclass (ZC - heating only)Contrasted
Junkers ZC 28-1 MFACerastar / Ceraclass (ZC - heating only)Contrasted
Junkers ZC 28-1 MFKCerastar / Ceraclass (ZC - heating only)Contrasted
Junkers ZWE 23-4 AEurostar / Cerastar (ZWE / ZWSE)Contrasted
Junkers ZWE 24-4 HAEurostar / Cerastar (ZWE / ZWSE)Contrasted
Junkers ZWE 24-4 HKEurostar / Cerastar (ZWE / ZWSE)Contrasted
Junkers ZWE 28-4 HAEurostar / Cerastar (ZWE / ZWSE)Contrasted
Junkers ZWSE 23-4 MFKEurostar / Cerastar (ZWE / ZWSE)Contrasted
Junkers ZWSE 28-4 MFAEurostar / Cerastar (ZWE / ZWSE)Contrasted
Junkers ZWSE 28-5 MFAEurostar / Cerastar (ZWE / ZWSE)Contrasted
Junkers ZWSE 35-6 MFAEurostar / Cerastar (ZWE / ZWSE)Contrasted
Junkers ZWN 24-7 AEZWNContrasted
Junkers ZWN 24-7 KEZWNContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. 8747003700 is the part for your boiler

What determines it is not the boiler model, but the reference printed on the part you already have installed.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference 8747003700. If it is not visible, do not identify the part by its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms and faults that the gas valve 8747003700 resolves.

The gas valve regulates and modulates the gas flow to the burner. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The boiler tries to ignite, a clicking sound is heard, but the flame does not appear.

    Cause: One of the two solenoid valves (EV1 or EV2) is not opening correctly and gas is not reaching the burner.

    Measure with a multimeter that both coils receive 24V~ at the moment of ignition before replacing the entire gas valve.

  • 02

    The boiler keeps locking out and needs to be reset every few cycles.

    Cause: An intermittent fault in the opening of the gas valve causes the control board not to detect a stable flame and to shut down for safety.

    Check if the lock always coincides with the cold start; if so, first check the condition of the ionization electrode.

  • 03

    The gas consumption seems higher than normal for the same feeling of warmth.

    Cause: If the gas valve does not close completely between cycles, it allows some extra gas to pass through even if there is no obvious leak.

    Compare the consumption with previous bills and rule out other causes (insulation, thermostat) before attributing it to the gas valve.

  • 04

    When measuring with a multimeter, the current in the coil does not reach the expected values.

    Cause: A damaged coil inside EV1 or EV2 does not generate the necessary force to open the gas flow.

    Before changing the gas valve, check that the connector is not oxidized and that the wire is not frayed, as this can also result in low current readings.

Fault codes from Junkers that this part resolves.

CodeFaultDiagnosis and solution
FAAfter the gas disconnection: The flame is still detected.The gas valve does not close tightly (leak/blockage) and the control continues to read ionisation current even though the gas has been cut off. Verify with a leak test and observe that the ionisation signal disappears when closed, and that the solenoid valve closes correctly.
d7Fault in the regulating valve.The electronics detect a fault in the gas valve (open/shorted coils or jammed mechanism). Check control voltage and coil continuity/ohmage, and ensure the valve opens/closes by measuring pressure on the ramp.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Data sheet for the gas valve Junkers 8747003700

Catalogue reference
8747003700
Brand
Junkers
Type of part
Gas valves
Units in stock
0 units
Status
Refurbished
Warranty
1 year
Shipping
1-2 business days
Return
14 days

Data read on the part and in the manufacturer's documentation

What we have not been able to verify does not appear here.

Model
845 Sigma
Code printed on the part
0063AS4831
Maximum inlet pressure
60 mbar
EV1 coil
24 V~
Maximum current
165 mA
Working ambient temperature
-15 °C to 60 °C
Batch and manufacturing date
Date 11/23, batch 3114629, no. 2197
Frequently Asked Questions

Frequently asked questions about the gas valve 8747003700

Does this SIT valve work for a Junkers ZWC24-1MF2A boiler?
Yes, it is on the list of compatible boilers along with ZC24-1MFA, ZSC24-3MFA, ZWN24-7MFA23, and ZWSE28-4MFA.
Who manufactures this gas valve for the Junkers Cerastar ZWN24-7MFA23?
SIT (Sit S.p.A., Italy), model 845 Sigma.
Does the code printed on the label of this gas valve match the reference 8747003700 from the catalog?
Yes, the OEM code printed 8 747 003 700 matches the catalog reference 8747003700.
When does this valve fail in a Junkers Cerastar boiler?
When the boiler does not ignite the burner or is blocked due to a gas supply fault.
What is the maximum current that the solenoid valves EV1 and EV2 of this part can support?
165 mA at most, according to the label.
What input pressure does this valve of the ZWN24-7MFA23 accept?
60 mbar at most, according to the label.

Spare parts related to Junkers Ceraclass Excellence / Comfort (ZWC)

Delivery 1–2 daysworking days, mainland Spain
1-year warrantyreviewed and tested
14-day returnuninstalled parts