Vaillant Gas Valve VMW ES 242 2 5 Turbomax Plus Ref. 053560

Vaillant Gas Valve VMW ES 242 2 5 Turbomax Plus Ref. 053560

75 €VAT includedIn stock · 1 unit

Gas valve: refurbished spare part that regulates and modulates the gas flow to the burner. Useful if there are ignition faults or the flame does not modulate. Compatible with VMW 242/2-3 R1, VMW 242/2-5 R1, VMW 240/2-5 R1 (ref. 053560). Includes a one-year warranty and delivery within 2–4 working days in the EU.

1
Consult via WhatsApp
Delivery in 2–4 working days
1-year warranty
14-day return
Technical support

Key Data

Reference
053560
Brand
Vaillant
Type of part
Gas valves
Available units
1 unit in stock
Status
Refurbished
Warranty
1 year
Shipping
2–4 working days (EU)
Return
14 days

The same part (ref. 053560) equips these models. Verified compatibility; check the reference before purchasing.

Vaillant atmoTEC/turboTEC PRO+ (series /2 R1-R2, VMW combi)

  • VMW 242/2-3 R1
  • VMW 242/2-5 R1
  • VMW 240/2-5 R1
  • VMW 282/2-5 R1
  • VMW 280/2-5 R1
  • VMW 24/282-5 R1

Vaillant atmoTEC/turboTEC PRO+ (series /2 R1-R3, VM heating only)

  • VM 242/2-5 R1
  • VM 282/2-5 R1
  • VM 202/2-5 R1
  • VM 240/2-5 R1
  • VM 280/2-5 R1

Fault codes related to this part (not the entire boiler). They usually have more possible causes: first rule out electrodes, wiring/connections, and gas supply. Verified with ≥3 sources.

CodeWhat does it mean?Cause and diagnosis (this part)
F.61Fault: gas valve operation.The PCB cannot actuate/modulate the gas valve (coils shorted/open or defective wiring harness), so it does not open/close correctly; check coil resistance, wiring continuity, and control voltage during the ignition attempt.
F.62Gas valve disconnection delay.The valve takes time to close or does not close tightly, leaving a flame signal after stopping; check tightness/closing time and ensure ionization disappears when the gas is cut off.
F.28Fault during appliance start-up: failed ignition attempts.If the valve does not open or is improperly adjusted, gas does not reach the burner and no flame is detected; verify that it receives the opening command and check pressures (inlet and burner pressure) at startup.
F.29The flame goes out during operation and the next ignition attempt fails.A valve that regulates poorly or gets stuck can cause a drop in flow/pressure and loss of ionisation during operation; check the stability of pressure downstream of the valve under load and the signal/power supply to the modulator.
F.27Safety shutdown: flame simulation.If the valve does not close completely (internal leak), the electronics may 'see' a flame with the valve closed; check the valve's tightness and the absence of ionisation signal with the gas cut off.
How do I know if this gas valve is the one for my boiler?
Verify the reference 053560 printed and ensure your model is on the list of compatible ones; also compare the connections with the original part. It is a SIT part.
What is it used for?
The gas valve regulates and modulates the gas flow to the burner.
Ignition faults, does not modulate, or smells of gas?
It could be the gas valve. IMPORTANT: gas handling ONLY by an authorised technician.
Which models is it suitable for?
Part shared by various models (see Compatibility). If your model does not appear, send us a photo of the marking and we will confirm it.
Installation and recommendations
Installation and pressure adjustment by authorised technician; mandatory leak check.
What does refurbished mean and what coverage does it have?
Part removed from a boiler out of service, inspected and tested. Includes 1-year warranty and 14-day return policy. Delivery within 2–4 working days in the EU.

Spare Parts Related Boiler VMW ES 242 2 5 Turbomax Plus