SIT 845 Sigma Gas Valve Vaillant VMW 24/282-5 R1 Ref. 053560
RefurbishedVaillantGas valvesSIT

SIT 845 Sigma Gas Valve Vaillant VMW 24/282-5 R1 Ref. 053560

Stock · 1 unit

SIT gas valve model 845 Sigma, with two solenoids (EV1 and EV2), modulator, and outlet pressure regulator. The SIT logo and model 845 Sigma are printed on the part itself. It regulates the gas flow to the burner; it should be replaced if the boiler does not ignite, loses flame, modulates poorly, or has a leak.

VAT included

Compatibility

Vaillant boilers compatible with reference 053560

Gas valve with reference 053560. 11 verified compatibilities: VMW 242/2-3 R1 and VMW 242/2-5 R1.

Proven compatibility

Boiler modelFamilyVerification
Vaillant VMW 242/2-3 R1Vaillant atmoTEC/turboTEC PRO+ (series /2 R1-R2, VMW combi)Contrasted
Vaillant VMW 242/2-5 R1Vaillant atmoTEC/turboTEC PRO+ (series /2 R1-R2, VMW combi)Contrasted
Vaillant VMW 240/2-5 R1Vaillant atmoTEC/turboTEC PRO+ (series /2 R1-R2, VMW combi)Contrasted
Vaillant VMW 282/2-5 R1Vaillant atmoTEC/turboTEC PRO+ (series /2 R1-R2, VMW combi)Contrasted
Vaillant VMW 280/2-5 R1Vaillant atmoTEC/turboTEC PRO+ (series /2 R1-R2, VMW combi)Contrasted
Vaillant VMW 24/282-5 R1Vaillant atmoTEC/turboTEC PRO+ (series /2 R1-R2, VMW combi)Contrasted
Vaillant VM 242/2-5 R1Vaillant atmoTEC/turboTEC PRO+ (series /2 R1-R3, VM heating only)Contrasted
Vaillant VM 282/2-5 R1Vaillant atmoTEC/turboTEC PRO+ (series /2 R1-R3, VM heating only)Contrasted
Vaillant VM 202/2-5 R1Vaillant atmoTEC/turboTEC PRO+ (series /2 R1-R3, VM heating only)Contrasted
Vaillant VM 240/2-5 R1Vaillant atmoTEC/turboTEC PRO+ (series /2 R1-R3, VM heating only)Contrasted
Vaillant VM 280/2-5 R1Vaillant atmoTEC/turboTEC PRO+ (series /2 R1-R3, VM heating only)Contrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. 053560 is the part for your boiler

What determines it is not the boiler model, but the reference printed on the part you already have installed.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference 053560. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms and faults that the gas valve 053560 resolves.

The gas valve regulates and modulates the gas flow to the burner. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The boiler does not ignite and locks up when starting.

    Cause: One of the solenoid valves (EV1 or EV2) does not open and gas does not reach the burner.

    Check that both electrical connectors of the gas valve are properly fitted before replacing it.

  • 02

    The flame rises and falls without reason, or the boiler modulates the power poorly.

    Cause: The modulator of the gas valve does not properly regulate the gas flow according to demand.

    Check for any voltage drops or poor connections in the installation that could affect the modulator.

  • 03

    A gas smell or a hissing sound is detected near the gas valve.

    Cause: The outlet pressure regulator or an internal gasket is losing its seal.

    Locate the exact point with soapy water before replacing the part; it could be a loose connection, not the valve.

  • 04

    The boiler starts but immediately locks out due to flame detection failure.

    Cause: The valve takes time to open or does not provide the minimum flow for the burner to ignite.

    Check the ionization electrode and its wiring before assuming the problem is the gas valve.

Fault codes from Vaillant that this part resolves.

CodeFaultDiagnosis and solution
F.61Fault: gas valve operation.The PCB cannot actuate/modulate the gas valve (coils shorted/open or defective wiring harness), so it does not open/close correctly; check coil resistance, wiring continuity, and control voltage during the ignition attempt.
F.62Gas valve disconnection delay.The valve takes time to close or does not close tightly, leaving a flame signal after stopping; check tightness/closing time and ensure ionization disappears when the gas is cut off.
F.28Fault during appliance start-up: failed ignition attempts.If the valve does not open or is improperly adjusted, gas does not reach the burner and no flame is detected; verify that it receives the opening command and check pressures (inlet and burner pressure) at startup.
F.29The flame goes out during operation and the next ignition attempt fails.A valve that regulates poorly or gets stuck can cause a drop in flow/pressure and loss of ionisation during operation; check the stability of pressure downstream of the valve under load and the signal/power supply to the modulator.
F.27Safety shutdown: flame simulation.If the valve does not close completely (internal leak), the electronics may 'see' a flame with the valve closed; check the valve's tightness and the absence of ionisation signal with the gas cut off.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Data sheet for the gas valve Vaillant 053560

Catalogue reference
053560
Brand
Vaillant
Type of part
Gas valves
Units in stock
1 unit
Status
Refurbished
Warranty
1 year
Shipping
1-2 business days
Return
14 days

Data read on the part and in the manufacturer's documentation

What we have not been able to verify does not appear here.

Manufacturer
SIT (logo on the part)
Model
845 Sigma
SIT code
0845078
Maximum inlet pressure
Pi max. 60 mbar
Outlet pressure
Po 1-20 mbar
Solenoid valves
EV1 200V~50Hz 9.2VA class B / EV2 200V~50Hz 2.8VA class J
Modulator
MD max 17V DC, max. 43 mA
Frequently Asked Questions

Frequently asked questions about the gas valve 053560

Which manufacturer has the gas valve for the Vaillant VMW 24/282-5 R1?
SIT, model 845 Sigma, according to the logo printed on the part itself.
Is this valve compatible with the Vaillant VMW 24/282-5 R1?
Yes, VMW 24/282-5 R1 is on the list of compatible boilers.
What outlet pressure does this valve regulate in the Vaillant VMW 242/2-3 R1?
Po 1-20 mbar, according to the label.
How do I know that reference 053560 corresponds to this gas valve of the Vaillant VMW 240/2-5 R1?
The factory code SIT 0845078 is printed on the part; its connection to the reference 053560 is only confirmed by one source, so it is advisable to verify it on your own as well.
What fault does replacing this gas valve in a Vaillant VMW 242/2-3 R1 resolve?
It is replaced if the boiler does not ignite, loses flame, or shows leakage.
What is the reference for this gas valve?
The reference for this gas valve is VGCVR1.