SIT 845 Sigma Gas Valve For Fagor FE-20E/1N - Code 0845061
SIT 845 Sigma gas valve, with two solenoids (EV1 and EV2) and flame modulator (MD), manufactured in Padova, Italy. It is multi-gas (ALLGAS) and regulates the gas flow to the burner in Fagor boilers FE-20E/1N and FE/FEE series. It is replaced when the boiler does not ignite, gas does not reach the burner, or it locks due to valve failure.
VAT included
Consult via WhatsAppFagor boilers compatible with reference MU0809100
Gas valve with reference MU0809100. 12 verified compatibilities: FE-20E/2N and FE-20E/2B.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Fagor FE-20E/2N | Fagor Eco Compact FE-20E | Contrasted |
| Fagor FE-20E/2B | Fagor Eco Compact FE-20E | Contrasted |
| Fagor FE-20E | Fagor Eco Compact FE-20E | Contrasted |
| Fagor FE-24E | Fagor FE (rest of series) | Contrasted |
| Fagor FE-27E | Fagor FE (rest of series) | Contrasted |
| Fagor FE-24NOX | Fagor FE (rest of series) | Contrasted |
| Fagor FA-20E2N | Fagor FA | Contrasted |
| Fagor FA-23EN | Fagor FA | Contrasted |
| Fagor FEB-20E | Fagor FEB | Contrasted |
| Fagor FEE-20 | Fagor FEE | Contrasted |
| Fagor CA-20EN | Fagor CA | Contrasted |
| Fagor CE-20E | Fagor CE | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if ref. MU0809100 is the part for your boiler
What determines it is not the boiler model, but the reference printed on the part you already have installed.
- Find the reference printed on the installed part and check whether it matches the catalogue reference MU0809100. If it is not visible, do not identify the part from its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms and faults that the gas valve MU0809100 resolves.
The gas valve regulates and modulates the gas flow to the burner. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The boiler tries to ignite, but the burner doesn't fully light up.
Cause: One of the two solenoid valves (EV1 or EV2) is not opening and is not allowing enough gas to pass to the burner.
Before replacing the gas valve, rule out that the blockage is coming from the flue gas evacuation or the ionization electrode, as they cause the same symptom.
- 02
There is no gas or very little gas reaching the burner, even though you can hear the ignition attempt.
Cause: The main solenoid valve gets stuck or does not open completely due to dirt or wear on the seat.
Check that the main shut-off valve is fully open and that the gas inlet pressure is normal for the household.
- 03
The flame rises and falls on its own, not adjusting well to the heat demand.
Cause: The modulator (MD) of the gas valve is not properly dosing the gas flow to the burner.
Check first if the problem occurs only in domestic hot water or also in heating; if it's only in one of the two, it's probably not the gas valve.
- 04
The boiler locks out with a gas valve fault warning as soon as it starts.
Cause: The control unit does not receive confirmation of the gas valve opening within the safety time and cuts off the gas.
Perform a reset and note if the lockout always occurs at the same point in the ignition cycle before replacing the part.
Fault codes for Fagor that this part resolves.
| Code | Fault | Diagnosis and solution |
|---|---|---|
| F1 | Lockout due to ignition fault (flame not established). | The faulty/stuck gas valve may not open or modulate at startup, and insufficient gas may reach for ionization; check voltage in coils during the ignition attempt and pressure/flow in the ramp, ensuring the valve opens. |
| F6 | Flame detection with the burner at rest (parasitic flame). | If the gas valve does not close hermetically, it allows gas to pass and a residual flame persists; check the valve's closure/sealing when stopped and rule out a false ionization signal. |
| F10 | Fault in the control or closure of the gas valve. | Fault in the valve or its control circuit (coils/relays) prevents proper opening/closing; check coil continuity, control voltage from the PCB, and ensure the flame extinguishes when closure is commanded. |
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Data sheet for the gas valve Fagor MU0809100
- Catalogue reference
- MU0809100
- Brand
- Fagor
- Type of part
- Gas valves
- Units in stock
- 3 units
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- 1-2 business days
- Return
- 14 days
Data read on the part and in the manufacturer's documentation
What we have not been able to verify does not appear here.
- Manufacturer
- SIT
- Model
- 845 Sigma
- SIT code
- 0845061
- Place of manufacture
- Made in Italy (Padua)
- Gas
- ALLGAS (multi-gas)
- Maximum inlet pressure (Pi max)
- 60 mbar
- Outlet pressure (Po)
- 1-37 mbar
- EV1 coil
- 230V ~50Hz, class B
- EV2 coil
- 230V ~50Hz, 2.8 VA, class J
- Modulator (MD)
- max. 17V DC, max. 165 mA
- Ambient temperature
- 0/40°C
- Internal mold number
- 2063AS4831