SIT Gas Valve for Fagor FE-20E Ref. MU0809100
In the Fagor FE-20E boilers, the SIT Gas Valve, reference MU0809100, is installed. This valve regulates and allows the flow of gas to the burner according to the commands from the PCB. If it fails, you may notice that the boiler does not ignite, experience flame lockouts, or have modulation issues. It is compatible with models such as FE-20E/2N, FE-24E, and FA-20E2N, among others. It should be replaced when faults such as F1, F6, or F10 occur.
VAT included
Consult via WhatsAppFagor boilers compatible with reference MU0809100
Gas valve with reference MU0809100. 12 verified compatibilities: FE-20E/2N and FE-20E/2B.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Fagor FE-20E/2N | Fagor Eco Compact FE-20E | Contrasted |
| Fagor FE-20E/2B | Fagor Eco Compact FE-20E | Contrasted |
| Fagor FE-20E | Fagor Eco Compact FE-20E | Contrasted |
| Fagor FE-24E | Fagor FE (rest of series) | Contrasted |
| Fagor FE-27E | Fagor FE (rest of series) | Contrasted |
| Fagor FE-24NOX | Fagor FE (rest of series) | Contrasted |
| Fagor FA-20E2N | Fagor FA | Contrasted |
| Fagor FA-23EN | Fagor FA | Contrasted |
| Fagor FEB-20E | Fagor FEB | Contrasted |
| Fagor FEE-20 | Fagor FEE | Contrasted |
| Fagor CA-20EN | Fagor CA | Contrasted |
| Fagor CE-20E | Fagor CE | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if ref. MU0809100 is the part for your boiler
What determines it is not the boiler model, but the reference printed on the part you already have installed.
- Find the reference printed on the installed part and check whether it matches the catalogue reference MU0809100. If it is not visible, do not identify the part from its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms and faults that the gas valve MU0809100 resolves.
The gas valve regulates and modulates the gas flow to the burner. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The boiler does not ignite and there is no flame visible or audible when trying to start.
Cause: The ignition solenoid valve of the gas valve does not open, so gas does not reach the burner even though the rest of the cycle operates correctly.
Check that the main gas shut-off valve is fully open and that no other appliance is interrupting the supply before replacing the gas valve.
- 02
The boiler ignites but operates in bursts: it turns off and on by itself instead of maintaining a stable flame.
Cause: The modulation solenoid valve does not regulate the flow properly, and the flame oscillates between on and off.
Check the wiring and the connector of the gas valve to the PCB before replacing it; a loose connection can cause the same intermittent ignition.
- 03
There is a smell of gas near the boiler, especially next to the gas valve.
Cause: A worn internal seat in this gas valve can allow gas to pass through even when it is in the closed position.
Locate the exact source of the smell using soapy water on the connections before considering the valve as the culprit: many leaks are at a joint or fitting, not at the valve.
- 04
The boiler is locking out, indicating a gas supply issue, even though the supply is guaranteed.
Cause: The valve does not correctly transfer the gas flow to the internal detection system, and the control board interprets that there is no fuel.
Confirm with a manometer that the gas pressure is reaching the valve properly before replacing it, to first rule out an installation issue.
Fault codes for Fagor that this part resolves.
| Code | Fault | Diagnosis and solution |
|---|---|---|
| F1 | Lockout due to ignition fault (flame not established). | The faulty/stuck gas valve may not open or modulate at startup, and insufficient gas may reach for ionization; check voltage in coils during the ignition attempt and pressure/flow in the ramp, ensuring the valve opens. |
| F6 | Flame detection with the burner at rest (parasitic flame). | If the gas valve does not close hermetically, it allows gas to pass and a residual flame persists; check the valve's closure/sealing when stopped and rule out a false ionization signal. |
| F10 | Fault in the control or closure of the gas valve. | Fault in the valve or its control circuit (coils/relays) prevents proper opening/closing; check coil continuity, control voltage from the PCB, and ensure the flame extinguishes when closure is commanded. |
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Data sheet for the gas valve Fagor MU0809100
- Catalogue reference
- MU0809100
- Brand
- Fagor
- Type of part
- Gas valves
- Units in stock
- 2 units
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- 1-2 business days
- Return
- 14 days
Data read on the part and in the manufacturer's documentation
What we have not been able to verify does not appear here.
- Inlet pressure (Pi max)
- 60 mbar
- Outlet pressure (Po)
- 1-37 mbar
- EV1 (1st solenoid valve)
- 230V~50Hz, 9.2 VA class B
- EV2 (2nd solenoid valve/modulating)
- 230V~50Hz, 2.8 VA class J
- MD MAX
- +7V DC
- Maximum current
- 165 mA
- Ambient temperature
- 0/60°C
- Code (SIT)
- 0845061
- Date
- 0241
- Lot
- 2225472
- Nr
- 1374