Honeywell Gas Valve VK4105G For Fagor FE-25 NOx Ref. MUR000022
Honeywell gas valve VK4105G 1138.4 mounted on Fagor boilers FE-25 NOX and FE-25 NOX/1 N. It regulates and cuts off the gas flow to the burner. It is replaced in case of ignition failures, gas blockages, or electrical faults of the valve. Certified CAT III, maximum pressure 60 mbar, class B+J, for use between -15°C and 80°C.
VAT included
Consult via WhatsAppFagor boilers compatible with reference MUR000022
Gas valve with reference MUR000022. A proven compatibility: FE 25 NOX/1 N.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Fagor FE 25 NOx/1 N | Fagor FE NOX | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if ref. MUR000022 is the part for your boiler
What determines it is not the boiler model, but the reference printed on the part you already have installed.
- Find the reference printed on the installed part and check whether it matches the catalogue reference MUR000022. If it is not visible, do not identify the part from its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms and faults that the gas valve MUR000022 resolves
The gas valve regulates and modulates the gas flow to the burner. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The boiler tries to ignite but locks out immediately, without producing a flame.
Cause: The valve is not receiving power to the coil or it is not opening, so gas does not reach the burner at startup.
Measure with a multimeter if current is reaching the gas valve connector during the ignition attempt; if it is not, check the PCB and the wiring first.
- 02
There is a smell of gas near the boiler, more noticeable around the valve area.
Cause: A fault in the internal closure of the valve can allow a minimal amount of gas to pass through even with the boiler turned off.
Check the gas inlet and outlet connections with soapy water before replacing the gas valve; a leak at a joint can be resolved without changing the part.
- 03
The flame does not regulate well: it stays either too high or too low depending on the heat demand.
Cause: If the modulation mechanism of the gas valve fails, the gas flow does not adjust to the signal sent by the PCB.
Check that the modulator connector is properly inserted and free of moisture before assuming the gas valve is faulty.
- 04
The coil of the gas valve is not receiving power or it is not opening, although the rest of the boiler starts normally.
Cause: An electrically damaged coil prevents the valve from opening the gas flow even if the ignition cycle is correct.
Before replacing the valve, check the fuse on the PCB and the continuity of the wiring to the coil: a blown fuse presents identical symptoms.
Fault codes for Fagor that this part resolves.
| Code | Fault | Diagnosis and solution |
|---|---|---|
| F1 | Ignition fault (flame not established). | If the gas valve does not open or opens insufficiently during the ignition attempt, no gas reaches the burner and the boiler locks out due to lack of flame. Check the power supply to the coils/solenoids and pressure at the valve inlet during start-up. |
| F6 | Flame detected with burner off (parasitic flame). | An incomplete closure of the gas valve may allow gas to pass through and maintain a residual flame after shutdown. Check the tightness/closure of the on-off valves of the gas valve and ensure the flame extinguishes when cut off; perform a leak test and closure test on the valve itself. |
| F10 | Fault in the gas valve control. | The electronics command the solenoid valves to close/open, and the valve does not respond (coil/relay fault) or does not close properly; the system detects it and locks. Check continuity and consumption of the coils, commands from the PCB, and effective closure by measuring pressure at the valve port during the shutdown cycle. |
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Data sheet for the gas valve Fagor MUR000022
- Catalogue reference
- MUR000022
- Brand
- Fagor
- Type of part
- Gas valves
- Units in stock
- 1 unit
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- 1-2 business days
- Return
- 14 days
Data read on the part and in the manufacturer's documentation
What we have not been able to verify does not appear here.
- Manufacturer
- Honeywell
- Component code
- VK4105G 1138.4
- Category/pressure
- CAT III Pmax 60 mbar Class B+J
- Ambient temperature
- -15°C / 80°C
- CE code
- CE.065AA31806
- Place of manufacture
- Made in the Netherlands
- Compatibility indicated on label
- Use with 2456 AA 234V version only