Radiant 3-Way Valve Actuator Motor Fagor FE 25 NOx 1 N Ref. 96032LP
When you turn on the hot water tap or activate the heating, the Fagor FE 25 NOX 1 N 3-Way Valve Actuator Motor is responsible for directing the water between both circuits. Its function is to switch the water flow, ensuring it reaches where it is needed. If you notice that you have hot water but no heating, or vice versa, it is possible that this part is failing. It is compatible with the Fagor FE 25 NOX/1 N boiler, among others. It is recommended to replace it if it shows these symptoms.
VAT included
Consult via WhatsAppFagor boilers compatible with reference 96032LP
3-way valve with reference 96032LP. A proven compatibility: FE 25 NOX/1 N.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Fagor FE 25 NOx/1 N | Fagor FE NOX | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if the part number 96032LP is the one for your boiler
What determines it is not the boiler model, but the reference printed on the part you already have installed.
- Find the reference printed on the installed part and check whether it matches the catalogue reference 96032LP. If it is not visible, do not identify the part from its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms and faults that the 3-way valve 96032LP resolves.
The 3-way valve diverts water between heating and domestic hot water. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The boiler does not switch between heating and domestic hot water.
Cause: The motor does not have enough power to fully move the valve shutter.
Check if the actuator receives power when the boiler requests the change, before considering it faulty.
- 02
The actuator does not move or makes noise when changing position.
Cause: The internal gears of the motor are worn or broken and do not transmit the rotation.
Check if the motor hums without turning the valve; this indicates a problem with the motor and not with the valve.
- 03
The boiler gets stuck in heating or in domestic hot water and does not change even if you try.
Cause: The actuator stops halfway and does not activate the limit switch.
Check if the fault occurs consistently in the same direction; this suggests that one end of the path is blocked.
- 04
It smells like burnt plastic or the actuator is hot to the touch.
Cause: The electric motor has burned out due to forcing the rotation against a jammed gas valve.
Before changing the actuator, check that the valve turns freely by hand; if it is stiff, the new motor will burn out again.
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Data sheet for the Fagor 96032LP three-way valve
- Catalogue reference
- 96032LP
- Brand
- Fagor
- Type of part
- 3-way valves
- Units in stock
- 3 units
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- Delivery time shown at checkout
- Return
- 14 days