Fagor Gas Valve FE24E N Ref. MU0809100
RefurbishedFagorGas valvesSIT

Fagor Gas Valve FE24E N Ref. MU0809100

Stock · 5 units

The Fagor Gas Valve FE24E N, manufactured by SIT and with reference MU0809100, regulates the gas flow to the burner according to the instructions on the boiler's PCB. If it malfunctions, the boiler may fail to ignite, show flame lockouts, or have modulation issues. This valve is compatible with models such as the FE-24E, FE-27E, and FA-20E2N, among others. It is recommended to replace it when symptoms such as fault code F1, which indicates a lockout due to ignition failure, or fault code F10, which indicates a fault in the control or closure of the gas valve, are detected.

VAT included

Compatibility

Fagor boilers compatible with reference MU0809100

Gas valve with reference MU0809100. 12 verified compatibilities: FE-20E/2N and FE-20E/2B.

Proven compatibility

Boiler modelFamilyVerification
Fagor FE-20E/2NFagor Eco Compact FE-20EContrasted
Fagor FE-20E/2BFagor Eco Compact FE-20EContrasted
Fagor FE-20EFagor Eco Compact FE-20EContrasted
Fagor FE-24EFagor FE (rest of series)Contrasted
Fagor FE-27EFagor FE (rest of series)Contrasted
Fagor FE-24NOXFagor FE (rest of series)Contrasted
Fagor FA-20E2NFagor FAContrasted
Fagor FA-23ENFagor FAContrasted
Fagor FEB-20EFagor FEBContrasted
Fagor FEE-20Fagor FEEContrasted
Fagor CA-20ENFagor CAContrasted
Fagor CE-20EFagor CEContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. MU0809100 is the part for your boiler

What determines it is not the boiler model, but the reference printed on the part you already have installed.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference MU0809100. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms and faults that the gas valve MU0809100 resolves.

The gas valve regulates and modulates the gas flow to the burner. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The boiler does not ignite or locks up right when the burner starts.

    Cause: One of the two coils EV1/EV2 is not receiving current or is not opening on time.

    Check if the blockage always occurs at the same step of the startup cycle before replacing the gas valve.

  • 02

    There is a smell of gas near the gas valve, even with the boiler turned off.

    Cause: Leak in the valve body or in the inlet and outlet fittings

    Close the main gas valve and check if the smell disappears before touching anything else.

  • 03

    The burner modulates poorly: it goes from high flame to low abruptly, without transition.

    Cause: One of the two EV1/EV2 coils fails and disrupts the gas distribution between stages.

    First, rule out a draft problem or the flow sensor; if the modulation also fails in domestic hot water, it points more towards the gas valve.

Fault codes for Fagor that this part resolves.

CodeFaultDiagnosis and solution
F1Lockout due to ignition fault (flame not established).The faulty/stuck gas valve may not open or modulate at startup, and insufficient gas may reach for ionization; check voltage in coils during the ignition attempt and pressure/flow in the ramp, ensuring the valve opens.
F6Flame detection with the burner at rest (parasitic flame).If the gas valve does not close hermetically, it allows gas to pass and a residual flame persists; check the valve's closure/sealing when stopped and rule out a false ionization signal.
F10Fault in the control or closure of the gas valve.Fault in the valve or its control circuit (coils/relays) prevents proper opening/closing; check coil continuity, control voltage from the PCB, and ensure the flame extinguishes when closure is commanded.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Data sheet for the gas valve Fagor MU0809100

Catalogue reference
MU0809100
Brand
Fagor
Type of part
Gas valves
Units in stock
5 units
Status
Refurbished
Warranty
1 year
Shipping
1-2 business days
Return
14 days

Data read on the part and in the manufacturer's documentation

What we have not been able to verify does not appear here.

SIT code
0845061
Internal mold number
0063AS4831
Maximum inlet pressure (Pi max)
60 mbar (ALLGAS)
Outlet pressure (Po)
1-37 mbar
EV1 coil
230V~50Hz, 9.2 VA class B
EV2 coil
230V~50Hz, 2.8 VA class J
Maximum motor voltage (MD max)
17V DC
Maximum current
165 mA
Ambient temperature
0/60°C
Frequently Asked Questions

Frequently asked questions about the gas valve MU0809100

Is this FE24E N valve suitable for the Fagor FE20E1N boiler?
Yes, it is among the compatible models: FE 24 NOX, FE20E, FE20E1N, and FE24E.
What code is engraved on this Fagor FE24E N gas valve?
SIT code 0845061, confirmed on the label and matching external sources.
What is the gas outlet pressure at which the gas valve of the Fagor FE24E N operates?
Between 1 and 37 mbar, according to the label.
Why is this gas valve changed in a Fagor FE24E N boiler?
It is replaced when the boiler does not ignite, there is a gas leak in the valve, or the ignition or modulation of the burner fails.

Spare parts related to Fagor Eco Compact FE-20E

Delivery 1–2 daysworking days, mainland Spain
1-year warrantyreviewed and tested
14-day returnuninstalled parts
Technical supportwe verify your model
Fagor Gas Valve FE24E N Ref. MU0809100