Gas Valve Isofast C 35 E-A - Honeywell VK8525M - Ref. 4000 124 345

Gas Valve Isofast C 35 E-A - Honeywell VK8525M - Ref. 4000 124 345

Honeywell gas valve type VK8525M, identified by the reference 4000 124 345 printed on the label. It regulates the flow of gas to the burner. It is installed in the Isofast C 35 E-A boiler and in the compatible models listed. The replacement requires first confirming the fault of the part through technical diagnosis, even when the boiler does not ignite, shuts down by itself, or fails to start the flame.

Type of part
Gas valves
Catalogue reference
S1071500
Warranty
1 year
VAT included Stock · 6 units
Compatibility

Saunier Duval boilers compatible with reference S1071500

Gas valve with reference S1071500. 28 verified compatibilities: C24E and C25E.

Proven compatibility

Boiler modelFamilyVerification
Saunier Duval C24EThemafastContrasted
Saunier Duval C25EThemafastContrasted
Saunier Duval C28EThemafastContrasted
Saunier Duval C30EThemafastContrasted
Saunier Duval F24EThemafastContrasted
Saunier Duval F25EThemafastContrasted
Saunier Duval F25E H-MODThemafastContrasted
Saunier Duval F30EThemafastContrasted
Saunier Duval F30E H-MODThemafastContrasted
Saunier Duval C24EThemaclassicContrasted
Saunier Duval C25EThemaclassicContrasted
Saunier Duval F24EThemaclassicContrasted
Saunier Duval F25EThemaclassicContrasted
Saunier Duval F AS 24EThemaclassicContrasted
Saunier Duval F AS 25EThemaclassicContrasted
Saunier Duval F AS 30EThemaclassicContrasted
Saunier Duval C24EThematekContrasted
Saunier Duval F24EThematekContrasted
Saunier Duval F30E H-MODIsofastContrasted
Saunier Duval F35E H-MODIsofastContrasted
Saunier Duval C16EOpaliaContrasted
Saunier Duval F11EOpaliaContrasted
Saunier Duval F14EOpaliaContrasted
Saunier Duval F17EOpaliaContrasted
Saunier Duval C24EThemaContrasted
Saunier Duval C25EThemaContrasted
Saunier Duval F24EThemaContrasted
Saunier Duval F25EThemaContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. S1071500 is the part for your boiler

The part reference, model, and equipment revision must be verified against the manufacturer's documentation.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference S1071500. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms that require diagnosis in the gas valve S1071500

The gas valve regulates and modulates the gas flow to the burner. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The boiler does not ignite even after you reset it.

    Cause: If the gas valve does not open, no gas enters the burner and ignition does not occur.

    Check if another gas appliance in the house is working properly to rule out a supply cut before inspecting the gas valve.

  • 02

    The boiler starts up well but turns off by itself during operation.

    Cause: An intermittent fault in the coil or a poor connection in the connector can interrupt the gas flow while the boiler is running.

    Check that the electrical connectors of the gas valve are properly tightened and free of rust; a loose connection can cause symptoms similar to those of a faulty valve.

  • 03

    There is a smell of gas near the gas valve.

    Cause: This can happen if the internal shutter does not seal properly and causes a small constant leak.

    With the boiler turned off, apply soapy water to the inlet and outlet connections of the gas valve to identify the exact point of the leak.

  • 04

    The display shows a flame fault or error after attempting to ignite it.

    Cause: The control board does not receive confirmation that gas is flowing and the flame is stable, and it locks out for safety.

    First, check the ignition electrode and the spark transformer; a weak spark can cause the same fault as a gas valve that does not open.

Fault codes Saunier Duval that require diagnosis

CodeFaultTechnical checks
F1Ignition fault.The gas block S1071500 does not open or is misaligned and does not provide flow during the spark attempt; check with a manometer at the valve ports (inlet/outlet) and measure voltage/continuity in coils during startup.
F.28Start-up fault: ignition failed.Fault in the gas valve assembly (block S1071500) or in its stepper motor prevents opening/modulating the gas during startup; check flow pressure and valve operation (measurement at ports and coil supply) during the ignition attempt.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Data sheet for the Saunier Duval gas valve S1071500.

Catalogue reference
S1071500
Uniclima internal SKU
VGIC35EA
Brand
Saunier Duval
Type of part
Gas valves
Units in stock
6 units
Status
Refurbished
Warranty
1 year
Shipping
Delivery time shown at checkout
Return
14 days

Part data and available documentation

Contrast the label codes, PCB, and revision with the installed part; they are not necessarily equivalent references.

type
VK8525M
reference
4000 124 345
output pressure
2.15 mbar
maximum pressure
60 mbar
coil voltage
24 VDC
coil consumption
6 VA
V1
22 Vdc (4VA)
V2
24 Vdc (6VA)
class
B+B
group
1
gas
NATURAL GAS
protection rating
IP 20
country of manufacture
Made in Czech Republic
date/batch code
202/04
Documentation

Manuals and technical documentation

Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.

Frequently Asked Questions

Frequently asked questions about the gas valve S1071500

Who manufactures the gas valve Ref. 4000 124 345 for the Isofast C 35 E-A?
Honeywell, type VK8525M.
Is this valve suitable for the Isofast C 35 E-A boiler?
Yes, it is on the list of compatible boilers.
What is the outlet pressure of the valve on the Isofast C 35 E-A?
2.15 mbar, according to the label.
Is this gas valve for the Isofast C 35 E-A for natural gas or propane?
The label indicates natural gas (GAZ NATUREL).
What voltage does the coil of this Honeywell VK8525M gas valve operate at?
24 Vdc, 6 VA.
Is this valve Ref. 4000 124 345 suitable for an Opalia C 16 E boiler?
Yes, it is among the compatible models, along with Combitek C 24 E, Isofast F 30 E H-MOD, Isosplit C 35 E, Opalia F 14 E, Thema C 24 E, and Themaclassic C 24 E.

Spare parts related to Saunier Duval Themafast

Entrega calculada por destino Delivery time shown at checkout
1-year warranty reviewed and tested
14-day return uninstalled parts
Technical support we verify your model
Gas Valve Isofast C 35 E-A - Honeywell VK8525M - Ref. 4000 124 345