Ignition Connector Anstoss VZ 2/10 HDC 600 - Cointra SPC 21 EI - Ref. 9158878
Refurbished Cointra Gas valves Anstoss (ZIG)

Ignition Connector Anstoss VZ 2/10 HDC 600 - Cointra SPC 21 EI - Ref. 9158878

Ignition connector/block manufactured by Anstoss, model VZ 2/10 HDC 600, mounted on the Honeywell VK4105M gas valve. It is used in Cointra ED 21 EI, SP 21 EI, SP 27 EI, SPA 27 EI, SPC 21 EI, and SPI 21 EI boilers. It operates at 220-240 V, 1.5 VA, and 50-60 Hz. The replacement requires first confirming the fault of the part through technical diagnosis, even when the boiler does not ignite due to a fault in this block.

Type of part
Gas valves
Catalogue reference
9158878
Warranty
1 year
VAT included Stock · 3 units
Compatibility

Cointra boilers compatible with reference 9158878

Gas valve with reference 9158878. Six confirmed compatibilities: 21 EI and 21 EI.

Proven compatibility

Boiler modelFamilyVerification
Cointra 21 EIEDContrasted
Cointra 21 EISPContrasted
Cointra 27 EISPContrasted
Cointra 27 EISPAContrasted
Cointra 21 EISPCContrasted
Cointra 21 EISPIContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. 9158878 is the part for your boiler

The part reference, model, and equipment revision must be verified against the manufacturer's documentation.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference 9158878. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms that require diagnosis in the gas valve 9158878

The gas valve regulates and modulates the gas flow to the burner. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The boiler does not ignite and the click of the gas valve is not heard when starting.

    Cause: The ignition block is not receiving power to activate the gas valve coil.

    Measure with a multimeter if power is reaching the connector during the start attempt before replacing it.

  • 02

    The ignition intermittently fails: sometimes it lights and sometimes it doesn't.

    Cause: There is a poor connection in the connector, which may loosen or lose continuity due to the vibrations of the boiler.

    Check that the connector is properly seated in its housing and that the terminals are not loose or corroded.

  • 03

    A flame failure warning appears on the screen just when trying to start.

    Cause: The block does not activate the gas valve within the time expected by the control board, so the burner does not ignite.

    Reset the boiler and check if the warning appears at the same point in the cycle before changing the block.

Fault codes Cointra that require diagnosis

CodeFaultTechnical checks
A09Gas valve anomalyThe gas valve may be faulty or have interrupted actuator/wiring, preventing its opening or modulation; check the continuity of the wiring and power supply to the actuator and ensure that the valve opens on demand.
A16Gas valve anomalyThis symptom may be related to the part, but it does not confirm that it is faulty. A technician must check the equipment and its inspection according to the manual before deciding on a repair or replacement.
F50Gas valve anomalyModulating actuator error (wiring interrupted) or faulty valve; check continuity of the actuator/coil and control voltage, and replace the valve if it does not respond.
A62There is no communication between the control board and the gas valve.The valve may be faulty or not responding to the signal from the control board; check connectors and wiring between the PCB and the valve, presence of control signal, and replace the valve if it does not communicate.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Data sheet for the Cointra gas valve 9158878

Catalogue reference
9158878
Uniclima internal SKU
VGCSPC21EI
Brand
Cointra
Type of part
Gas valves
Units in stock
3 units
Status
Refurbished
Warranty
1 year
Shipping
Delivery time shown at checkout
Return
14 days

Part data and available documentation

Contrast the label codes, PCB, and revision with the installed part; they are not necessarily equivalent references.

Manufacturer
Anstoss (ZIG)
Component code
VZ 2/10 HDC
Voltage
220-240 V
Power
1.5 VA
Frequency
50-60 Hz
Temperature range
-20°C / +60°C
Frequently Asked Questions

Frequently asked questions about the gas valve 9158878

Is the Anstoss VZ 2/10 HDC 600 connector a complete gas valve?
No. It is an ignition connector/block that is mounted on the Honeywell VK4105M gas valve.
Who manufactures the ignition connector Ref. 9158878 for the Cointra SPC 21 EI?
Anstoss (brand ZIG), according to the screen printing on the label.
Does this Anstoss connector work for a Cointra SP 27 EI boiler?
Yes, it is among the compatible models: ED 21 EI, SP 21 EI, SP 27 EI, SPA 27 EI, SPC 21 EI, and SPI 21 EI.
What voltage does the ignition connector of the Cointra SPC 21 EI operate at?
A 220-240 V, 1.5 VA and 50-60 Hz.
Why did the catalog refer to this Anstoss ignition connector as a 'valve'?
It is a cataloging error detected during the review; the title has been corrected after identifying the part on the label.

Spare parts related to Cointra SP

Entrega calculada por destino Delivery time shown at checkout
1-year warranty reviewed and tested
14-day return uninstalled parts
Technical support we verify your model
Ignition Connector Anstoss VZ 2/10 HDC 600 - Cointra SPC 21 EI - Ref. 9158878