Fagor Gas Valve FE/FEE/FA/CE SIT 845 Sigma Ref. 0063AS4831
Refurbished Fagor Gas valves SIT

Fagor Gas Valve FE/FEE/FA/CE SIT 845 Sigma Ref. 0063AS4831

The gas valve Fagor FE/FEE/FA/CE SIT 845 Sigma Ref. 0063AS4831 regulates the flow of gas to the burner according to the commands from the boiler's PCB. When it fails, you may notice that the boiler does not ignite, experience flame lockouts, or detect a malfunction in gas modulation. This valve is compatible with various models such as FE-20E, FE-24E, FA-20E2N, and CE-20E, among others. A technician must confirm through diagnosis whether it needs to be replaced when fault codes F1, F6, or F10 appear, indicating issues with ignition or valve control.

Type of part
Gas valves
Catalogue reference
MU0809100
Warranty
1 year
VAT included Stock · 3 units
Compatibility

Fagor boilers compatible with reference MU0809100

Gas valve with reference MU0809100. 12 verified compatibilities: FE-20E/2N and FE-20E/2B.

Proven compatibility

Boiler modelFamilyVerification
Fagor FE-20E/2NFagor Eco Compact FE-20EContrasted
Fagor FE-20E/2BFagor Eco Compact FE-20EContrasted
Fagor FE-20EFagor Eco Compact FE-20EContrasted
Fagor FE-24EFagor FE (rest of series)Contrasted
Fagor FE-27EFagor FE (rest of series)Contrasted
Fagor FE-24NOXFagor FE (rest of series)Contrasted
Fagor FA-20E2NFagor FAContrasted
Fagor FA-23ENFagor FAContrasted
Fagor FEB-20EFagor FEBContrasted
Fagor FEE-20Fagor FEEContrasted
Fagor CA-20ENFagor CAContrasted
Fagor CE-20EFagor CEContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. MU0809100 is the part for your boiler

The part reference, model, and equipment revision must be verified against the manufacturer's documentation.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference MU0809100. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms that require diagnosis in the gas valve MU0809100

The gas valve regulates and modulates the gas flow to the burner. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The boiler does not ignite or turns off by itself as soon as it starts.

    Cause: The SIT 845 gas valve does not open the gas flow and the flame does not form.

    Check that the network pressure regulator is functioning correctly and that the gas valve is fully open.

  • 02

    It smells like gas near the boiler even when it is off.

    Cause: A gasket or the gas valve shutter may be leaking gas.

    Close the gas valve and ventilate; do not reset the boiler until a technician checks the leak.

  • 03

    The boiler ignites well but loses the flame after a few seconds.

    Cause: The maintenance coil of the gas valve does not maintain the gas flow after ignition.

    Check the ionization electrode and its wiring; a poor connection can cause the same issue as the gas valve.

Fagor fault codes that require diagnosis

CodeFaultTechnical checks
F1Lockout due to ignition fault (flame not established).The faulty/stuck gas valve may not open or modulate at startup, and insufficient gas may reach for ionization; check voltage in coils during the ignition attempt and pressure/flow in the ramp, ensuring the valve opens.
F6Flame detection with the burner at rest (parasitic flame).If the gas valve does not close hermetically, it allows gas to pass and a residual flame persists; check the valve's closure/sealing when stopped and rule out a false ionization signal.
F10Fault in the control or closure of the gas valve.Fault in the valve or its control circuit (coils/relays) prevents proper opening/closing; check coil continuity, control voltage from the PCB, and ensure the flame extinguishes when closure is commanded.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Data sheet for the gas valve Fagor MU0809100

Catalogue reference
MU0809100
Uniclima internal SKU
VGFEE26MA
Brand
Fagor
Type of part
Gas valves
Units in stock
3 units
Status
Refurbished
Warranty
1 year
Shipping
Delivery time shown at checkout
Return
14 days

Part data and available documentation

Contrast the label codes, PCB, and revision with the installed part; they are not necessarily equivalent references.

Valve model
845 Sigma
Variant
Allgas
Component manufacturer
SIT
Place of manufacture
Padua (Italy)
Part code (label)
0063AS4831
Frequently Asked Questions

Frequently asked questions about the gas valve MU0809100

Who manufactures this gas valve for the Fagor FE20E1N?
SIT, model 845 Sigma variant Allgas, manufactured in Padova (Italy), with the code 0063AS4831 readable on the label.
Does this SIT 845 Sigma valve work for the entire Fagor FE/FEE/FA/CE series?
Yes, according to the list of compatible boilers, it is suitable for the FE/FEE/FA/CE series, including the FE20E1N.
Where is this SIT valve that the Fagor CE uses manufactured?
In Padova, Italy, as stated on the part's label.

Spare parts related to Fagor Eco Compact FE-20E

Entrega calculada por destino Delivery time shown at checkout
1-year warranty reviewed and tested
14-day return uninstalled parts
Technical support we verify your model
Fagor Gas Valve FE/FEE/FA/CE SIT 845 Sigma Ref. 0063AS4831