Vaillant Turbo Tec VMW ES 282 2 5 SIT Gas Valve Ref. 053462

Vaillant Turbo Tec VMW ES 282 2 5 SIT Gas Valve Ref. 053462

Stock · 7 units

The Vaillant Turbo Tec VMW ES 282 2 5 SIT gas valve regulates and allows the flow of gas to the burner according to the commands from the control board. If it malfunctions, you will notice that the boiler does not ignite, there may be flame lockouts, or the gas modulation is not adequate. This valve is compatible with models such as the VMW 240-3, VMW 242-5, among others from the TurboTec and AtmoTec ranges. It is recommended to replace it when errors such as F.26, F.61, or F.28 are detected, which indicate problems with the gas valve.

VAT included

Compatibility

Vaillant boilers compatible with reference 053462

Gas valve with reference 053462. 19 verified compatibilities: VMW 240-3 and VMW 240-5.

Proven compatibility

Boiler modelFamilyVerification
Vaillant VMW 240-3turboTEC / turboTEC plus (VMW turbo)Contrasted
Vaillant VMW 240-5turboTEC / turboTEC plus (VMW turbo)Contrasted
Vaillant VMW 242-3turboTEC / turboTEC plus (VMW turbo)Contrasted
Vaillant VMW 242-5turboTEC / turboTEC plus (VMW turbo)Contrasted
Vaillant VMW 280-5turboTEC / turboTEC plus (VMW turbo)Contrasted
Vaillant VMW 282-5turboTEC / turboTEC plus (VMW turbo)Contrasted
Vaillant VMW 240/2-5turboTEC / turboTEC plus (VMW turbo)Contrasted
Vaillant VMW 242/2-5turboTEC / turboTEC plus (VMW turbo)Contrasted
Vaillant VMW 282/2-5turboTEC / turboTEC plus (VMW turbo)Contrasted
Vaillant VM 202-5atmoTEC / atmoTEC plus (VM open chamber)Contrasted
Vaillant VM 240-5atmoTEC / atmoTEC plus (VM open chamber)Contrasted
Vaillant VM 242-5atmoTEC / atmoTEC plus (VM open chamber)Contrasted
Vaillant VM 280-5atmoTEC / atmoTEC plus (VM open chamber)Contrasted
Vaillant VM 282-5atmoTEC / atmoTEC plus (VM open chamber)Contrasted
Vaillant VM 240/2-5atmoTEC / atmoTEC plus (VM open chamber)Contrasted
Vaillant VM 282/2-5atmoTEC / atmoTEC plus (VM open chamber)Contrasted
Vaillant VMI 280-7VMIContrasted
Vaillant VMI 282-7VMIContrasted
Vaillant VMI 32/362-7VMIContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. 053462 is the part for your boiler

What determines it is not the boiler model, but the reference printed on the part you already have installed.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference 053462. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms and faults that the gas valve 053462 resolves

The gas valve regulates and modulates the gas flow to the burner. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The boiler makes a loud bang when starting, like a small explosion, instead of igniting the flame smoothly.

    Cause: The gas valve allows too much gas to flow suddenly when starting, instead of opening gradually.

    Check that the burner and the combustion chamber are free of soot and accumulated dirt; this can also cause rough ignitions.

  • 02

    The boiler does not respond when requesting hot water or heating, although the control seems to be working fine.

    Cause: If the gas valve does not open, there is no flame even though the rest of the system is functioning correctly.

    Confirm that the thermostat or the control is actually requesting temperature and that it is not a programming issue before checking the gas valve.

  • 03

    In heating, everything works well, but when requesting hot water, the flame is weak or unstable.

    Cause: The valve may fail in modulation for the domestic hot water circuit, regardless of the heating.

    Open several taps at the same time or check the water flow; a low flow can also cause the flame in domestic hot water to be weak without it being the fault of the gas valve.

  • 04

    The stability of the flame varies when increasing or decreasing the power, although it ignites well at the beginning.

    Cause: The valve modulation system does not accurately follow the power demand indicated by the control unit.

    Check if the fault occurs consistently within the same power range; if so, it will help you determine that it is the gas valve and not another cause.

Fault codes from Vaillant that this part resolves.

CodeFaultDiagnosis and solution
F.26Fault: gas valve not functioning.The stepper motor/coils of the gas valve (SIT 053462) are open, shorted, or disconnected, so the valve does not operate; check coil resistance/insulation and stepper motor signal/return from the PCB during the ignition attempt.
F.61Gas valve activation error.The gas valve cannot be operated due to an internal fault (coils shorted/ground leakage) or wiring failure; confirm by measuring the resistance/insulation of coils, wiring harness, and control signal from the PCB.
F.62Gas valve disconnection delay.The gas valve remains stuck/not sealed and takes time to close, maintaining the flame signal after the closure command; check for tightness and closing time (ionisation/analyser) and rule out internal leakage of the valve assembly.
F.28The appliance does not start: failed ignition attempts during startup.The gas valve does not open or is incorrectly adjusted, preventing flow during ignition; check inlet pressure, control signal, and actual valve opening during the ignition sequence.
F.29The flame goes out during operation and subsequent ignition attempts fail.Intermittent fault of the gas valve (flow drop/leakage when hot) causes flame loss; check pressure stability and valve operation under load and confirm by replacing/adjusting the valve assembly if necessary.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Data sheet for the gas valve Vaillant 053462

Catalogue reference
053462
Brand
Vaillant
Type of part
Gas valves
Units in stock
7 units
Status
Refurbished
Warranty
1 year
Shipping
Delivery time shown at checkout
Return
14 days
Documentation

Manuals and technical documentation

Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.

Frequently Asked Questions

Frequently asked questions about the gas valve 053462

Does this gas valve work for my Vaillant VMW 242-5 boiler?
Yes, the VMW 242-5 is on the list of compatible boilers, along with other models such as VMW 240-3, VMW 282-5, and more.
What is the purpose of the gas valve Vaillant Turbo Tec VMW ES 282 2 5 SIT Ref. 053462?
Feed the gas circuit of the burner in the boiler.
How many models are compatible with this gas valve?
A total of 19 models are compatible with this gas valve.
What fault codes can be associated with this gas valve?
The documented fault codes are F.26, F.61, F.62, F.28, and F.29.
Where can I find the reference for this gas valve?
The reference for this valve is VGTTVMWES25.
Is this valve suitable for the turboTEC range?
Yes, it is compatible with several models from the turboTEC range, such as VMW 240-3 and VMW 282-5.

Spare parts related to Vaillant turboTEC / turboTEC plus (VMW turbo)

Entrega calculada por destinoDelivery time shown at checkout
1-year warrantyreviewed and tested
14-day returnuninstalled parts
Technical supportwe verify your model
Vaillant Turbo Tec VMW ES 282 2 5 SIT Gas Valve Ref. 053462