Chaffoteaux Centora 3 24 CF PCB Ref. 61308277
If your Chaffoteaux Centora 3 24 CF boiler does not start, locks out, or behaves erratically, you may need the Chaffoteaux Centora 3 24 CF PCB. This control board is responsible for managing the ignition, burner modulation, pump, and safety features of the boiler. When it fails, fault code 30 may appear, indicating a lack of communication with the main board. This part is compatible with several models from the Centora, Calydra Delta, Hyxia II, and Nexia ranges, among others. It is advisable to replace it when the mentioned symptoms or operational errors are detected.
VAT included
Consult via WhatsAppChaffoteaux boilers compatible with reference 61308277
PCB with reference 61308277. 21 verified compatibilities: Centora 1.14 CF and Centora 1.24 CF.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Chaffoteaux Centora 1.14 CF | Centora | Contrasted |
| Chaffoteaux Centora 1.24 CF | Centora | Contrasted |
| Chaffoteaux Centora 1.24 FF | Centora | Contrasted |
| Chaffoteaux Centora 2.24 CF | Centora | Contrasted |
| Chaffoteaux Centora 2.24 FF | Centora | Contrasted |
| Chaffoteaux Centora 2.24 VMC | Centora | Contrasted |
| Chaffoteaux Centora 2.28 CF | Centora | Contrasted |
| Chaffoteaux Centora 2.28 FF | Centora | Contrasted |
| Chaffoteaux Centora 3.14 CF | Centora | Contrasted |
| Chaffoteaux Centora 3.24 CF | Centora | Contrasted |
| Chaffoteaux Centora 3.24 FF | Centora | Contrasted |
| Chaffoteaux Calydra Delta 24 CF | Calydra Delta | Contrasted |
| Chaffoteaux Calydra Delta 24 FF | Calydra Delta | Contrasted |
| Chaffoteaux Calydra Delta 28 CF | Calydra Delta | Contrasted |
| Chaffoteaux Calydra Delta 28 FF | Calydra Delta | Contrasted |
| Chaffoteaux Hyxia II 24 CF | Hyxia II | Contrasted |
| Chaffoteaux Hyxia II 24 FF | Hyxia II | Contrasted |
| Chaffoteaux Hyxia II 28 FF | Hyxia II | Contrasted |
| Chaffoteaux Nexia 18 CF | Nexia | Contrasted |
| Chaffoteaux Nexia 24 CF | Nexia | Contrasted |
| Chaffoteaux Nexia 24 FF | Nexia | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if ref. 61308277 is the part for your boiler
What determines it is not the boiler model, but the reference printed on the part you already have installed.
- Find the reference printed on the installed part and check whether it matches the catalogue reference 61308277. If it is not visible, do not identify the part from its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms and faults that the PCB 61308277 resolves.
The PCB controls the ignition, modulation, and safety features of the boiler. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The boiler does not turn on: there is no light or sound.
Cause: The PCB is not receiving power or is not distributing power to the rest of the circuit.
Check the fuse on the PCB and the input voltage before considering that the board is faulty.
- 02
A different fault code appears every few days, with no changes in the installation.
Cause: This indicates an intermittent internal fault in the PCB, not a real fault in another component.
Note the codes that appear: if the same one does not repeat, the suspicion is the PCB.
- 03
The thermostat is calling for heat, but the boiler is not responding, as if it were turned off.
Cause: The PCB does not process the demand signal from the thermostat or the room control.
Check that the demand cable is properly connected to the terminals of the PCB and that there is no oxidation on the connector.
- 04
The extractor or the pump buzz continuously, even though the boiler does not request it.
Cause: The relay on the PCB has stuck and is not cutting off the power.
Disconnect that component from the PCB and measure if there is still voltage coming from that output; if it continues, the relay is not functioning.
Fault codes Chaffoteaux that this part resolves
| Code | Fault | Diagnosis and solution |
|---|---|---|
| 30 | "Communication fault with the main PCB." | It is generated when the main PCB does not respond via the bus with the control board; check 230 V/24 V on the PCB, the 1.25 A fuse, and the continuity/connectors of the harness between the panel and the board; if everything is correct, the PCB is faulty. |
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Data sheet for the Chaffoteaux 61308277 PCB.
- Catalogue reference
- 61308277
- Brand
- Chaffoteaux
- Type of part
- PCBs (control boards)
- Units in stock
- 5 units
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- Delivery time shown at checkout
- Return
- 14 days
Data read on the part and in the manufacturer's documentation
What we have not been able to verify does not appear here.
- voltage
- 230V
- frequency
- 50/60Hz
Manuals and technical documentation
Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.
- Chaffoteaux Centora 2.24 CF Manual (PDF)Document © Chaffoteaux, provided as a technical reference.