Chaffoteaux Sime 2 23 PCB Ref. 61010047

Chaffoteaux Sime 2 23 PCB Ref. 61010047

45 €VAT includedIn stock · 12 units

PCB (control board): refurbished spare part that controls the ignition, modulation, and safety features of the boiler. Useful if the boiler does not ignite, locks up, or the display is unresponsive. Compatible with Siam 2 23 E CF, Siam 2 23 E FF, Siam 2 23 e CF-FF (ref. 61010047). Includes a one-year warranty and delivery within 2–4 working days in the EU.

1
Consult via WhatsApp
Delivery in 2–4 working days
1-year warranty
14-day return
Technical support

Key Data

Reference
61010047
Brand
Chaffoteaux
Type of part
PCBs (control boards)
Available units
12 units in stock
Status
Refurbished
Warranty
1 year
Shipping
2–4 working days (EU)
Return
14 days

The same part (ref. 61010047) equips these models. Verified compatibility; check the reference before purchasing.

Siam

  • Siam 2 23 E CF
  • Siam 2 23 E FF
  • Siam 2 23 e CF-FF

Elexia

  • Elexia CF B
  • Elexia CF N
  • Elexia FF B
  • Elexia FF N

MC

  • MC 23 CF
  • MC 23 FF
  • MC CF
  • MC FF

Nectra

  • Nectra 1.23 CF
  • Nectra 1.23 FF
  • Nectra 2.23 CF
  • Nectra 2.23 FF
  • Nectra 2.28 CF
  • Nectra 2.28 FF
  • Nectra Top 1.23 CF
  • Nectra Top 2.23 CF
  • Nectra Top 2.23 FF

Fault codes related to this part (not the entire boiler). They usually have more possible causes: first rule out electrodes, wiring/connections, and gas supply. Verified with ≥3 sources.

CodeWhat does it mean?Cause and diagnosis (this part)
EEPROM errorEEPROM memory fault on the control board.The integrated EEPROM on the PCB 61010047 is corrupted or unreadable; check 5/12 V voltages on the PCB and, if it persists after a reset, replace or reprogram the PCB.
Communication error between boiler PCB and user interface boardLoss of communication between the main PCB and the interface/user board.The PCB 61010047 does not establish/receive data via the bus with the interface; check connectors/wiring between the PCB and interface and the 5 V power supply. If they are correct, the fault is with the PCB.
Main PCB fault codeMain PCB fault.Internal fault of the PCB 61010047 (regulation/internal readings); after ruling out moisture/connectors and verifying service voltages, replace the PCB.
How do I know if this PCB is for my boiler?
Check the reference 61010047 printed and ensure your model is on the list of compatible ones; also compare the connections with the original part.
What is it used for?
The PCB controls the ignition, modulation, sensor readings, and safety features of the boiler.
Is the boiler not igniting, locking out, or is the control board unresponsive?
After ruling out mains voltage, fuse, and connectors, a damaged PCB causes lockouts, blackouts, or erratic display. Repair the external cause before installing the new one.
Which models is it suitable for?
Part shared by various models (see Compatibility). If your model does not appear, send us a photo of the marking and we will confirm it.
Installation and recommendations
After installation, a technician must adjust the service parameters (type of gas, power settings) and check combustion and safety features.
What does refurbished mean and what coverage does it have?
Part removed from a boiler out of service, inspected and tested. Includes 1-year warranty and 14-day return policy. Delivery within 2–4 working days in the EU.

Spare Parts Related Boiler Sime 2 23