Chaffoteaux Calydra 23 FF / 28 FF Power PCB Ref. 61010592

Chaffoteaux Calydra 23 FF / 28 FF Power PCB Ref. 61010592

Stock · 1 unit

When you open the tap or start the heating, the Chaffoteaux Calydra 23 FF / 28 FF Power PCB Ref. 61010592 is responsible for controlling the ignition, the modulation of the burner, and the operation of the pump. If this part fails, you will notice that the boiler does not start, gets locked, or exhibits erratic behavior, potentially showing fault code 30: Communication fault with the main board. It is compatible with the Calydra 23 FF, Calydra 28 FF models, and some models from the MC range. It is recommended to replace it upon detecting these issues in the operation of your boiler.

VAT included

Compatibility

Chaffoteaux boilers compatible with reference 61010592

PCB with reference 61010592. Three confirmed compatibilities: Calydra 23 FF and Calydra 28 FF.

Proven compatibility

Boiler modelFamilyVerification
Chaffoteaux Calydra 23 FFCalydraContrasted
Chaffoteaux Calydra 28 FFCalydraContrasted
Chaffoteaux MC FFMCContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. 61010592 is the part for your boiler

What determines it is not the boiler model, but the reference printed on the part you already have installed.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference 61010592. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms and faults that the PCB 61010592 resolves.

The PCB controls the ignition, modulation, and safety features of the boiler. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The boiler is not receiving power: neither the pump, nor the fan, nor the gas valve are working.

    Cause: The power board distributes the current; if it fails, no power reaches anything even if the control sends the command.

    Measure if the boiler is receiving mains voltage and check that the main fuse has not blown before considering the power PCB as faulty.

  • 02

    The boiler does not start even though the display is on and responds to the buttons.

    Cause: The control works because it has its own power supply, but the power to the components (pump, fan) is cut off.

    With the boiler running, check if the pump or the fan shows any signs of life (vibration, noise); if nothing moves, it could be a power issue.

  • 03

    Intermittent fault: sometimes it works and other times it stops for no apparent reason.

    Cause: A loose contact or a damaged trace on the power PCB can intermittently interrupt the current.

    Check the connectors on the power PCB, ensuring that they are not loose or corroded, before considering replacing it.

  • 04

    The differential switch of the house trips when the boiler tries to start.

    Cause: A short circuit on the power board can cause a ground fault when powering the components.

    Isolate the boiler from the rest of the electrical circuit and check if the differential trips only with it connected, before assuming that it is the PCB.

Fault codes Chaffoteaux that this part resolves

CodeFaultDiagnosis and solution
30Communication fault with the main PCBThe ignition/power PCB may fail or lose communication with the control panel/display. Check voltages on the PCB (230 Vac input and 5/12 Vdc auxiliary), grounds, and continuity/connectors of the display–PCB harness; if everything is correct and the issue persists, replace the PCB (Ref. 61010592).

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Data sheet for the Chaffoteaux 61010592 PCB.

Catalogue reference
61010592
Brand
Chaffoteaux
Type of part
PCBs (control boards)
Units in stock
1 unit
Status
Refurbished
Warranty
1 year
Shipping
1-2 business days
Return
14 days

Data read on the part and in the manufacturer's documentation

What we have not been able to verify does not appear here.

CE marking
present (visible in the connection area)
Voltage at the terminal block
230V
Component classification (external sources)
Power PCB, Britony/Calydra/Genesis range
Frequently Asked Questions

Frequently asked questions about the PCB 61010592

Is this power PCB Ref. 61010592 compatible with the Calydra 23 FF?
Yes, the power PCB Ref. 61010592 is compatible with the Calydra 23 FF.
What fault does this power board resolve in the Calydra 28 FF?
It is replaced when the electrical control of the boiler fails or stops supplying power to the elements of the installation.
What voltage does the terminal block of this PCB work at in the Calydra?
At 230V, as indicated on the part's label.
How many models are compatible with the power board Ref. 61010592?
The power PCB is compatible with a total of 3 models: Calydra 23 FF, Calydra 28 FF, and MC FF.
What fault codes are documented for this PCB?
The documented fault code for this PCB is 30.
What is the reference for this power PCB?
The reference for this power PCB is PLCH096.

Spare parts related to Chaffoteaux Calydra

Delivery 1–2 daysworking days, mainland Spain
1-year warrantyreviewed and tested
14-day returnuninstalled parts
Technical supportwe verify your model
Chaffoteaux Calydra 23 FF / 28 FF Power PCB Ref. 61010592