Bertelli & Partners Cointra Essential 24 E PCB Ref. DBM10
RefurbishedCointraPCBs (control boards)Bertelli & Partners

Bertelli & Partners Cointra Essential 24 E PCB Ref. DBM10

If your boiler does not start, locks out, or exhibits erratic behavior, a technical diagnosis must confirm whether you need to replace the Bertelli & Partners Cointra Essential 24 E PCB, reference DBM10. This control board regulates the ignition, burner modulation, pump, and safety features of the boiler. When it fails, you may experience faults such as A02, F04, F05, F07, or A23. It is compatible with models from the Cointra Essential range, such as the Essential 24 E and the Essential 32 E, among others. A technician must confirm through diagnosis whether it needs to be replaced when these symptoms or faults are detected.

Catalogue reference
39823030
Warranty
1 year
VAT includedStock · 1 unit
Compatibility

Cointra boilers compatible with reference 39823030

PCB with reference 39823030. Two confirmed compatibilities: Essential 24 E and Essential 32 E.

Proven compatibility

Boiler modelFamilyVerification
Cointra Essential 24 ECointra EssentialContrasted
Cointra Essential 32 ECointra EssentialContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. 39823030 is the part for your boiler

The part reference, model, and equipment revision must be verified against the manufacturer's documentation.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference 39823030. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms that require diagnosis on the PCB 39823030

The PCB controls the ignition, modulation, and safety features of the boiler. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The boiler does not ignite or start on any attempt.

    Cause: The PCB controls the entire ignition process: if it doesn't work, the other components do not receive the command to start.

    Before replacing the PCB, check that power is reaching the boiler and that the internal fuse (if visible) is not blown.

  • 02

    There is no response from the thermostat or the boiler's own controls.

    Cause: The PCB processes both the outdoor thermostat and the panel controls; if it fails, both stop working.

    Do not force, hit, or bridge the component. Request a technical check according to the equipment manual before deciding on its replacement.

  • 03

    The boiler ignites but turns off after a few seconds, repeatedly.

    Cause: If the transformer supplying the PCB provides an irregular current, the electronics may start the cycle and cut it off immediately for safety.

    Before replacing the PCB, measure if the transformer output is stable; an unstable current there explains the cut without the rest of the circuit being damaged.

  • 04

    The display flickers or shows a PCB fault without a fixed pattern.

    Cause: A fault in the PCB without a fixed pattern usually indicates a cold solder joint or a component that only fails when hot.

    Before replacing it, check that the fault does not coincide with a spike in electrical consumption in the home (other appliances turning on at the same time), which would rule out the PCB.

Fault codes Cointra that require diagnosis

CodeFaultTechnical checks
A02Flame signal present with burner off.The PCB (control board) may interpret a false ionisation signal or mismanage the electrode input; verify by measuring the ionisation current and ruling out the electrode/wiring; if it persists, review/reprogram or replace the PCB.
F04Anomaly in the parameters of the control board.PCB parameters misconfigured or corrupted (memory/EEPROM); check by entering programming mode and restoring/adjusting values; if it doesn't save or reappears, the board is defective.
F05Anomaly in the parameters of the control board.Configuration error or fault in the PCB itself (in sealed models E it may also indicate a fan fault, but the brand documents the cause on the board); verify and reprogram parameters; if not corrected or not recorded, replace the PCB.
F07Anomaly in the parameters of the control board.Internal parameters of the PCB improperly adjusted/damaged; check the service menu and restore factory or prescribed parameters; if it reappears or does not allow saving, PCB is faulty.
A23Anomaly in the parameters of the control board.PCB configuration/firmware with inconsistent parameters; verify and reprogram parameters according to the manual; if not restored or reappears, PCB memory damaged → replace.
A24Anomaly in the parameters of the control board.Control parameters on the PCB out of range or corrupted; enter programming, correct/restore values and check that the PCB saves them; if not, replace the PCB.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Data sheet for the PCB Cointra 39823030

Catalogue reference
39823030
Uniclima internal SKU
PEE24E
Brand
Cointra
Type of part
PCBs (control boards)
Units in stock
1 unit
Status
Refurbished
Warranty
1 year
Shipping
Delivery time shown at checkout
Return
14 days

Part data and available documentation

Contrast the label codes, PCB, and revision with the installed part; they are not necessarily equivalent references.

Manufacturer
Bertelli & Partners
PCB code
DBM10
Documentation

Manuals and technical documentation

Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.

Frequently Asked Questions

Frequently asked questions about the PCB 39823030

Who manufactures the PCB for the Cointra Essential 24 E?
Bertelli & Partners, according to the text silk-screened on the PCB itself.
What code does my PCB need to have to be the DBM10?
The code DBM10, silk-screened next to the manufacturer's name Bertelli & Partners.
What fault does replacing this PCB resolve in the Cointra Essential 24 E?
It should be checked when the boiler does not ignite, does not respond to the thermostat, or presents a fault with the PCB. Replacement requires a technical diagnosis.
Entrega calculada por destinoDelivery time shown at checkout
1-year warrantyreviewed and tested
14-day returnuninstalled parts
Technical supportwe verify your model
Bertelli & Partners Cointra Essential 24 E PCB Ref. DBM10