Fagor PCB CONTROL 103 · MU0870700 for CE 20 EN and FEB-20 EN

Fagor PCB CONTROL 103 · MU0870700 for CE 20 EN and FEB-20 EN

The control PCB of the boiler monitors thermostats, sensors, and switches, and applies safety measures. It is suspected if the boiler does not ignite, there is a failure in ignition, or the temperature control is malfunctioning. This unit has a silkscreened output labeled PUMP.

internal SKU
PLC306
Warranty
1 year
VAT included Stock · 3 units
Compatibility

Compatible models

Check the listed models, version and part number before ordering the spare part.

Verified compatibility

Boiler modelFamilyVerification
Fagor CE 20 ENFagorVerified
Fagor FEB-20 ENFagorVerified

Models pending verification

These models are associated with this reference, but we have not finished verifying them yet, so we do not consider them compatibleIf your boiler is one of them, send us a photo of the part you are going to replace and we will verify it before you purchase.

Fagor Ecoplus FEB 20 E (Morco FEB20E)FagorUnconfirmed
Fagor FA20E2NFagorUnconfirmed
Fagor FA20E2F1GLPFagorUnconfirmed
Fagor FEB20EUK1NFagorUnconfirmed
Fagor FEB20E1NFagorUnconfirmed
Fagor CA20EGLPFagorUnconfirmed
Fagor FA20E2HNFagorUnconfirmed
Fagor FE28E1BFagorUnconfirmed
Fagor FEB20EFFagorUnconfirmed
Fagor FEB20EUKFagorUnconfirmed
Fagor CE 20 E-1 NFagorUnconfirmed

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if it is the part for your boiler

The part reference, model, and equipment revision must be verified against the manufacturer's documentation.

  1. Look for the code MU0870700 and the designation CONTROL103 on the PCB. In the FEB-20E, the manual places that code in the lower right corner of the PCB.
  2. Also compare 9328.F, 9328F071501492 RC and E5419266 with those on your PCB.
  3. Don't confuse it with the MU0868700, the previous PCB of the FEB-20E (its code is located at the bottom center): the manual states that the MU0870700 replaces it.
  4. Check the rating plate of your boiler: it should be CE 20 EN, Fagor FEB-20 EN, or Fagor Ecoplus FEB 20 E.
  5. If they match, call us at 911 17 77 77 with your boiler model and we will reserve it for you.
Diagnosis and fault codes

Symptoms and checks

The PCB controls the ignition, modulation, and safety features of the boiler. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    Five flashes of 1 second (fault code 5) in the FEB-20E

    Cause: The manufacturer's manual lists it as "Printed circuit board failure" for the MU0870700. Have a technician confirm it before replacing it.

  • 02

    It doesn't turn on, there is a fault with the ignition or the temperature control is malfunctioning.

    Cause: it is related to this PCB. A technician must first rule out the ignition, the sensors, and the wiring.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Technical data

Uniclima internal SKU
PLC306
Brand
Fagor
Type of part
PCBs (control boards)
Units in stock
3 units
Status
Refurbished
Warranty
1 year
Shipping
Depending on the country; cost shown at checkout
Return
14 days

Part data and available documentation

Contrast the label codes, PCB, and revision with the installed part; they are not necessarily equivalent references.

Transformer: marked primary
230 V; 50/60 Hz
Transformer: marked secondary
14 V; 12 VA
Inventory — Mounted yellow transformer
input 230 V; frequency 50/60 Hz; output 14 V; power 12 VA protection/primary fuse 80 mA/T
Inventory — PCB
indicated supply 230 V~; frequency 50 Hz maximum operating temperature 130 °C maximum operating temperature 105 °C output/screen printed function PUMP
Inventory — Application indicated in inventory
CE 20 EN MODEL 2
Inventory — Marked code
9328.F; 9328F071501492 RC
Manufacturer's manual data for the FEB-20E — Boiler power supply
230 V · 50 Hz, external fuse of 3 A · Manufacturer's manual Morco
Identification — Marked designation
CONTROL103
Identification — Marked code
MU0870700
Identification — Marked code
9328.F
Identification — Marked code
E5419266
Technical sheet: Transformer: primary marked
230 V; 50/60 Hz
Technical sheet: Transformer: marked secondary
14 V; 12 VA
Inventory data — Mounted yellow transformer
input 230 V; frequency 50/60 Hz; output 14 V; power 12 VA
Inventory data — Mounted yellow transformer
primary protection/fuse 80 mA/T
Inventory data — PCB
indicated supply 230 V~; frequency 50 Hz
Inventory data — PCB
maximum operating temperature 130 °C
Inventory data — PCB
maximum operating temperature 105 °C
Inventory data — PCB
output/screen printed PUMP
Inventory data — Application indicated in inventory
CE 20 EN
Inventory data — Application indicated in inventory
MODEL 2
Inventory data — Marked code
9328.F; 9328F071501492 RC
Before purchasing
  • To confirm: Fagor FA20E2N: /
  • Fagor FA20E2F1GLP: /
  • To confirm: Fagor FEB20EUK1N: /
  • To confirm: Fagor FEB20E1N
  • To confirm: Fagor CA20EGLP
  • To confirm: Fagor FA20E2HN
  • To confirm: Fagor FE28E1B
  • To confirm: Fagor FEB20EF: common list
  • To confirm: Fagor FEB20EUK: common list
  • To confirm: Fagor CE 20 E-1 N
  • Do not confuse: MU0868700 — Front PCB of the FEB-20E (its code is located at the bottom center of the board) — The manufacturer's manual states that MU0870700 is its direct replacement. Compare the code printed on your board.
  • FCB1180 along with MU0870700 in the title: and (Bright Grip repeats in other technical sheets), to be confirmed. list MU0870700 as Brandt module, also for washing machine.
  • The manufacturer's manual for the FEB-20E connects MU0870700 with this PCB. The manual explains MU0868700 as another one like the previous PCB.
  • Pending registered applications to confirm by model, variant, or programming: Fagor Ecoplus FEB 20 E (Morco FEB20E).
Frequently asked questions

Frequently asked questions

Where is the code for this PCB and which one should I compare?
The main code is MU0870700, marked on the plate; in the FEB-20E the manufacturer's manual places it in the lower right corner. It also includes CONTROL103, 9328.F, 9328F071501492 RC, and E5419266 (this one, from the yellow transformer). First, compare MU0870700.
Is it compatible with my boiler CE 20 EN or Fagor FEB-20 EN?
Check the status of each model in the compatibility sections; the pending variants are not validated. Registered: for the boilers CE 20 EN and Fagor FEB-20 EN. Check on the data plate which one is yours.
Is it compatible with the Fagor Ecoplus FEB 20 E (Morco FEB20E)?
Check the status of each model in the compatibility sections; the pending variants are not validated. The manufacturer's manual for the FEB-20E UK Ecoplus names the MU0870700 as its new type PCB; they also provide it, and (for the FEB20). Check that your PCB has MU0870700 or the previous MU0868700.
What is the difference between MU0870700 and MU0868700?
To confirm: According to the manufacturer's manual for the FEB-20E, MU0868700 is the previous PCB and MU0870700 is the new one, its direct replacement. It lists the PCB for the FEB-20E as MU0868700. The manual describes the new one with two blue transformers; this unit has one yellow and one blue: compare it with yours.
What other Fagor boilers are compatible with MU0870700?
Check the status of each model in the compatibility sections; the pending variants are not validated. To confirm, with: FA20E2N, FA20E2F1GLP and FEB20EUK1N (and: same list;); FEB20E1N, CA20EGLP, FA20E2HN and FE28E1B. With 1: FEB20EF and FEB20EUK (that common list) and the CE 20 E-1 N, different name from CE 20 EN. Only bring the FEB 20 EF-1 N (does not count).
What do MU0870700, CONTROL103, 9328.F, and FCB1180 mean?
MU0870700 is the Fagor code for the PCB (also provided as Electrolux). CONTROL103 is the marked designation; 9328.F and 9328F071501492 RC are on the control label (E.G.O.), and without additional confirmation, they are mentioned. FCB1180 is the Morco code for the FEB20E PCB: and they place it alongside MU0870700 in the title (: to be confirmed).
What should the technician check when installing it?
Before declaring the PCB faulty, check the primary fuse of 80 mA/T of the transformer (230 V → 14 V, 12 VA, marked on this unit). In the FEB-20E, the manual requests routing the fan cable downwards to reach terminal J10, repositioned. Have it installed by a qualified technician: 230 V and gas boiler.
Delivery to the EU in 2–6 working days Depending on the country; cost shown at checkout
1-year warranty inspected and tested
14-day return uninstalled parts
Technical support we verify your model
Fagor PCB CONTROL 103 · MU0870700 for CE 20 EN and FEB-20 EN