
Junkers PCB 8748300270 · For ZW 20-1 AME 23
Application for the exact variant pending confirmation. It is the control and management PCB of the boiler functions.
- Type of part
- Junkers
- Status
- Refurbished
- internal SKU
- PLC212
- Warranty
- 1 year
Compatible Junkers boilers
Junkers. 0 verified compatibilities. There are another 6 models that we are still checking.
Models pending verification
These models are associated with this reference, but we have not finished verifying them yet, so we do not consider them compatibleIf your boiler is one of them, send us a photo of the part you are going to replace and we will verify it before you purchase.
| Junkers Novatherm ZW 20 AME | Junkers | Unconfirmed |
|---|---|---|
| Junkers Novatherm ZW 20 KE | Junkers | Unconfirmed |
| Junkers Novatherm ZS 20 AME | Junkers | Unconfirmed |
| Junkers Novatherm ZW 20-1 KE | Junkers | Unconfirmed |
| Junkers Novastar ZW 20-1 AME 31, ZW 20-2 AME and ZW 20-2 KE | Junkers | Unconfirmed |
| Junkers ZW 20-1 AME 23 | Junkers | Unconfirmed |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if it is the part for your boiler
The part reference, model, and equipment revision must be verified against the manufacturer's documentation.
- Look for the code 8 748 300 270 (also written as 8748300270) on your PCB. This technical sheet is for that reference.
- Check the second marked code, 874 501 087, in the NEC JAPAN integrated circuit with 026-EF01/00.
- If your PCB has 8 748 300 371, it is the official breakdown code for the ZW 20 AME and ZW 20 KE: send us a photo from Contact to compare it.
- Look at the model on the boiler's rating plate: the ZW 20-1 AME 23 is registered.
- if they match, call us at 911 17 77 77 with the model of your boiler.
Symptoms that require diagnosis in the junkers
Common symptoms and faults
- 01
The boiler shuts down or locks out with fault code EA.
Cause: No flame detected: lack of gas, dirty ignition electrode, or poor ionization.
Press the reset button once. If it repeats, have a technician check the gas, the electrode, and its cable.
- 02
The red LED blinks once every 2 seconds and the burner does not start.
Cause: Moisture on the PCB, control electrode shorted to ground or NTC sensor.
Have a technician check it: verify the humidity and the condition of the PCB before replacing it.
- 03
The red LED flashes once per second: there is a spark, but the burner does not ignite and the boiler locks out.
Cause: Dirty ionization electrode or poor ionization, weak ignition or lack of gas.
Have a technician check it: the electrode and ignition are tested before replacing the PCB.
- 04
The red LED flashes twice per second and the boiler is locked.
Cause: Overtemperature: temperature limiter, thermal sensor or seized pump.
Have a technician check: circulation, the pump, and the thermal sensor.
Junkers fault codes that require diagnosis
| Code | Fault | Technical checks |
|---|---|---|
| EA | There is no ionization current: the boiler does not detect the flame and shuts down or locks out. | Press reset once. If it repeats, have a technician check the gas, the ignition electrode, and the ionization cable. If all that is fine, point to the PCB. |
| F0 | Internal fault of the PCB or its connections. | Check that the contacts on the PCB are properly connected. If the fault code persists, the PCB is the suspected part: have it checked by a technician. |
| FA | It continues to detect flame after closing the gas. | Have a technician check the wiring of the gas valve and the electrode. If the wiring is fine, it points to the PCB. |
| A7 | The NTC sensor for domestic hot water is faulty. | Have a technician check the sensor and its connection to the PCB. The PCB is suspected if the sensor is functioning properly. |
| E2 | The heating flow NTC sensor is faulty. | Have a technician check the heating sensor and its cable. The PCB is suspected if the sensor is fine. |
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Technical sheet: Junkers
- Uniclima internal SKU
- PLC212
- Brand
- Junkers
- Type of part
- Junkers
- Units in stock
- 10 pcs
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- Delivery time shown at checkout
- Return
- 14 days
Part data and available documentation
Contrast the label codes, PCB, and revision with the installed part; they are not necessarily equivalent references.
- Inventory — Integrated circuit subcomponent
- NEC JAPAN; 026-EF01/00; 8744 501 087; 9808KY002
- Inventory — Fuse
- 2.0 A
- Inventory — Subcomponent condenser
- 0.47 μF; 400 V
- Inventory — Application indicated in inventory
- ZW 20 1 AME 23
- Official list data — PCB in the parts list
- 8 748 300 371 («Control board»), pos. 7 · Official list ZS/ZW 20 AME and ZW 20 KE
- Official list data — Fuses of the control panel
- T 2 A (8 744 503 011) · T 2.5 A (1 904 521 342) · Official list ZS/ZW 20 AME and ZW 20 KE
- Identification — Marked code
- 8 748 300 270
- Identification — Marked code
- 874 501 087
- Inventory data — Integrated circuit subcomponent
- NEC JAPAN; 026-EF01/00; 8744 501 087; 9808KY002
- Inventory data — Fuse
- 2.0 A
- Inventory data — Subcomponent condenser
- 0.47 μF; 400 V
- Inventory data — Application indicated in inventory
- ZW 20 1 AME 23
- Pending applications to verify
- ZW 20 1 AME 23 — noted compatibility; pending confirmation by variant. It cites Junkers Novatherm ZW20-1AME and ZW20-1KE for 8748300371/ex8748300270; it warns that it may vary by serial number. Commercial declaration pending.
- Registered equivalents and substitutions
- Registered application: 8748300371 as a substitute for 8748300270. It is a commercial cross, pending documentation from the manufacturer and the serial number.
- To confirm: signs of failure for the PCB 8748300371 include the boiler not igniting or being unresponsive, erratic fault codes on the display, stuck relays or burnt traces, and unexpected resets.
- Junkers Novatherm ZW 20 AME — Official parts list + with reference 8748300371
- To confirm: Junkers Novatherm ZW 20 KE — Official parts list + with reference 8748300371
- Junkers Novatherm ZS 20 AME: official parts list (8 748 300 371)
- Junkers Novatherm ZW 20-1 KE — Technical sheet: Italian «ex 8748300270» + compatible with reference 8748300371
- To confirm: Junkers Novastar ZW 20-1 AME 31, ZW 20-2 AME and ZW 20-2 KE — with reference 8748300371
- Do not confuse: 8 717 207 452 — "Control unit" / "Switch box", item 1 of the official breakdown of the ZW 20 AME and ZW 20 KE — It is a different position than the PCB ("Leiterplatte").
- Do not confuse: 87483002460 — Reference for the PCB of the ZW20-1AME23 Novastar "atmospheric" — It is a different reference. Registered confirmation: the ZW 20-1 AME 23 with the 8748300270.
- The change 8748300270 → 8748300371 (to be confirmed) comes from an Italian source (sheet no. 1407: ), whose independence is not verified. An Italian breakdown of the ZW 20-1 AME states "ex 270-0" next to 8 748 300 371, without writing the complete code.
- PCB 8748300270 identified by. The official breakdown provides 8748300371 for the ZW 20 AME and KE; only Italian sources (sheet no. 1407, independence not verified) list it as a substitute.
- Pending registered applications to confirm by model, variant, or programming: Junkers ZW 20-1 AME 23.
