Junkers Control Board 8744501254 · PCB FD189 for ZWA24-1AM23
Application for the exact variant pending confirmation. It is the control PCB of a Junkers boiler. It has a chip with a label (EPROM) and a white module attached.
- Type of part
- Junkers
- Status
- Refurbished
- internal SKU
- PLC220
- Warranty
- 1 year
Compatible Junkers boilers
Junkers. 0 verified compatibilities. There are 2 other models that we are still checking.
Models pending verification
These models are associated with this reference, but we have not finished verifying them yet, so we do not consider them compatibleIf your boiler is one of them, send us a photo of the part you are going to replace and we will verify it before you purchase.
| Junkers ZWC24-1MFA | Junkers | Unconfirmed |
|---|---|---|
| Junkers ZWA24-1AM23 | Junkers | Unconfirmed |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if it is the part for your boiler
The part reference, model, and equipment revision must be verified against the manufacturer's documentation.
- Look for the chip (EPROM) label on the PCB: it should say 8 744 501 254 and LF 01.34 FD:188. On the printed circuit board, the code FD 189.
- Also compare the 8 746 301 238 from the welding side, the white module coupled 8 774 201 251, and the fuses marked F1 T2A, F2 T1.25A, and F3 T3.15A.
- Do not confuse it with the PCBs 8748300561, 8748300488, 8 748 300 496 or with 8 744 501 228: they are different codes.
- Check the rating plate to see that your boiler is a Junkers ZWA24-1AM23. If it is another model, compare the codes before ordering it.
- if they match, call us at 911 17 77 77 with the model of your boiler.
Symptoms that require diagnosis in the junkers
Common symptoms and faults
- 01
The boiler does not ignite and shows EA.
Cause: Gas shortage, air in the line, or defective ignition or ionization electrodes. There may also be moisture on the PCB.
Check the gas valve and press reset once. If it appears again, have a technician check it.
- 02
The boiler displays F0 on the screen.
Cause: Internal fault in the electronics, almost always in the PCB; sometimes it is defective ignition connections or wires.
Check the electrical connections and the ignition wires. If the fault code returns, have a technician check it to replace the PCB.
- 03
The boiler is not working and the indicators are not lighting up, even though there is a demand for heating.
Cause: F1 or F2 fuse, transformer, faulty electrical connection or printed circuit board.
A technician should check the voltage, the fuses, the transformer, and the PCB.
- 04
The heating is not working, but hot water is coming out.
Cause: Incorrect signal from the room thermostat, faulty thermostat, or defective PCB.
Have a technician check it, as they need to verify the room thermostat, its connections, and the PCB.
Junkers fault codes that require diagnosis
| Code | Fault | Technical checks |
|---|---|---|
| E9 | Safety temperature limiter activated on the supply. | Check the pressure of the installation, ensure the pump is working and the fuse of the PCB, and bleed the unit. If it happens again, have a technician check it. |
| d3 | The bridge is missing in the safety connector of the PCB (terminals 8-9 open). | Check that the jumper or connector of the thermostat is properly placed according to the diagram. If it is correct and the fault code persists, it points to the PCB; have a technician check it. |
| E2 | NTC sensor of the supply line faulty or disconnected. | Check the flow sensor and its connection cable. If the sensor is fine, point to the PCB; have a technician check it. |
| EA | No ignition flame detected. | Check that there is gas and press reset once. If it repeats, it points to the ignition or ionization electrodes, or the PCB; have a technician check it. |
| F0 | Internal electronic error (internal fault of the PCB or its connections). | Check the electrical connections and the securing of the ignition wires. If the issue persists, the PCB is usually the part that needs to be replaced; have a technician check it. |
| E0 | Internal fault in the PCB (control board). | Check for any moisture or sulfated contacts on the PCB. If the issue persists, the PCB needs to be replaced; have a technician check it. |
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Technical sheet: Junkers
- Uniclima internal SKU
- PLC220
- Brand
- Junkers
- Type of part
- Junkers
- Units in stock
- 1 unit
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- Delivery time shown at checkout
- Return
- 14 days
Part data and available documentation
Contrast the label codes, PCB, and revision with the installed part; they are not necessarily equivalent references.
- Marked port
- SCL;SDA;5V;GND
- Marked fuse
- T3.15A F3
- Inventory — Chip/EPROM label
- 8 744 501 254; LF 01.34 FD:188
- Inventory — Marked supply
- 230 V
- Inventory — Fuse F1
- T2A
- Inventory — Marked subcomponent
- 68 nK275~
- Inventory — Blue condenser
- 0.47 μF; 400 N9
- Inventory — Relay/subcomponent
- H11-24
- Inventory — White coupled module
- 8 774 201 251; E 372/6/6
- Inventory — Code visible on the welding face/label
- 8 746 301 238
- Inventory — Application indicated in inventory
- ZWA24-1AM23
- Identification — Marked code
- 8 744 501 254
- Identification — Marked code
- LF01.34
- Identification — Marked code
- FD188
- Identification — Marked code
- FD189
- Identification — Marked code
- HTIII-2a /BA BB BB
- Puerto marcado
- SCL;SDA;5V;GND
- Technical sheet: Marked fuse
- T1.25A F2
- Technical sheet: Marked fuse
- T3.15A F3
- Inventory data — Chip/EPROM label
- 8 744 501 254; LF 01.34 FD:188
- Inventory data — Marked supply
- 230 V
- Inventory data — Fuse F1
- T2A
- Inventory data — Marked subcomponent
- 68 nK275~
- Inventory data — Blue condenser
- 0.47 μF; 400 N9
- Inventory data — Relay/subcomponent
- H11-24
- Inventory data — White coupled module
- 8 774 201 251; E 372/6/6
- Inventory data — Code visible on the welding face/label
- 8 746 301 238
- Inventory data — Application indicated in inventory
- ZWA24-1AM23
- Additional markings
- Chip/EPROM label: 8 744 501 254; LF 01.34; FD:188. PCB silkscreen: FD 189. Fuses F1 T2A; F3 T3.15A; F2 T1.25A. Subcomponent marking 68 nK275~. Blue capacitor: 0.47 μF; 400 N9. Relay/subcomponent: H11-24. Coupled white module: 8 774 201 251; E 372/6/6. Code visible on solder joints/label: 8 746 301 238. Port: SCL; SDA; 5V; GND. Marked code HTIII-2a / BA BB BB.
- Pending applications to verify
- ZWA24-1AM23 — noted compatibility; pending confirmation by variant. Statements from (documentation 23/10/2026; revision 24/10/2026), pending confirmation by manufacturer. Check reference, revision, and serial number before use: Euromaxx ZWC 24-1 MFA · Euromaxx ZWC 28-1 MFA · Euromaxx ZWC 24-1 MFK · Euromaxx ZWC 28-1 MFK
- To confirm: Junkers ZWC24-1MFA: the 8744501254; others provide 8748300506 and 87144111740 for it.
- Do not confuse: 8748300561 — PCB (control board) that is a spare part ready for the Junkers ZWA24-1AM23 — It is another code: without additional confirmation read, it links it to 8744501254. It is not stated that they are interchangeable.
- Do not confuse: 8748300488 — PCB 288.45.0020 from a distributor (original code 87483004880) that lists the ZWA24-1AM23, the ZWA24-1KM31, and the ZWA24-1AM31 — It is another code: without additional confirmation read, it links to 8744501254.
- Do not confuse: 8 748 300 496 — PCB of the Eurosmart ZWA 24-1 A in the official spare parts list 7 181 465 343 — It is from the ZWA 24-1 A variant, not from the AM 23, and it is a different code: without additional confirmation read, it links to 8744501254.
- Do not confuse: 8748300506 / 87144111740 — Boards for the Junkers ZWC24-1MFA (the 87144111740 as "encoder") — They are other codes: without additional confirmation read, it links them to 8744501254.
- Do not confuse: 8 744 501 228 — Reference visible on the chip of a Junkers ZWA 24 advertised in — It looks similar in the first digits, but it is a different code. It is not listed as the same PCB.
- Different ones are provided for the ZWA24-1AM23 with other codes (8748300561, 8748300488). For that boiler, registered confirmation: this one, 8744501254: refer to the code printed on your PCB.
- registered. Outside of it, spare parts (ZWC24-1MFA) and (Junkers ZWA) provide the code 8744501254. We have not found an official parts list.
- Pending registered applications to confirm by model, variant, or programming: Junkers ZWA24-1AM23.