Junkers PCB OC-118 · 873791898A for ZWB30/32 1 A23
Refurbished Junkers Junkers

Junkers PCB OC-118 · 873791898A for ZWB30/32 1 A23

Application for the exact variant pending confirmation. PCB with registered application for Junkers ZWB30/32 1 A23. Their exact function and that of the separate green module, identified with the label 873792116A, are pending confirmation.

Type of part
Junkers
internal SKU
PLC231
Warranty
1 year
VAT included Stock · 1 unit
Compatibility

Compatible Junkers boilers

Junkers. 0 verified compatibilities. There are another 1 models that we are still checking.

Models pending verification

These models are associated with this reference, but we have not finished verifying them yet, so we do not consider them compatibleIf your boiler is one of them, send us a photo of the part you are going to replace and we will verify it before you purchase.

Junkers ZWB30/32 1 A23JunkersUnconfirmed

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if it is the part for your boiler

The part reference, model, and equipment revision must be verified against the manufacturer's documentation.

  1. Look for the code 873791898A on the label or bag of your spare part and the marking OC-118 on the printed circuit board.
  2. Check if your PCB has a separate green module and compare its label: 873792116A and 08 15 38 3805.
  3. Turn it over: on the back there should be a traceability label with 873791679A… and SV6.0.
  4. Check the data plate of your boiler to see that the model is Junkers ZWB30/32 1 A23, the one you have registered.
  5. if they match, call us at 911 17 77 77 with the model of your boiler.
Diagnosis and fault codes

Symptoms that require diagnosis in the junkers

Common symptoms and faults

  • 01

    The boiler does not ignite and the display shows EA.

    Cause: Flame not detected: gas valve closed, insufficient gas pressure, faulty electrodes or ignition cable, or blocked flue.

    Check that the gas valve is open and the gas pressure. Inspect the electrodes and their cable. If everything is fine, have a technician check it.

  • 02

    The display shows F0.

    Cause: Internal fault: faulty electrical contacts or ignition cables, or defective PCB.

    Check the electrical contacts and the ignition cables. If the fault code persists, have a technician replace the PCB.

  • 03

    The boiler stops due to excessive temperature and the display shows E9.

    Cause: The temperature limiter of the heat block or exhaust gases has tripped.

    Check the service pressure, the pump, and the fuses on the PCB, and bleed the unit. If the fault code returns, have a technician check it.

  • 04

    The boiler continues to detect flame after cutting off the gas, and FA appears on the display.

    Cause: Gas valve that does not close tightly, dirty condensate siphon, or defective electrodes.

    Check the gas valve, clean the condensate siphon, and inspect the electrodes. If the issue persists, have a technician check it.

  • 05

    The display shows CC: the boiler does not detect the external sensor.

    Cause: Interruption in the external sensor or its cable.

    Check that the outdoor sensor and its cable have no interruptions. If they are fine, have a technician check it.

  • 06

    A8 appears on the display: the boiler is not communicating with the controller.

    Cause: Communication interrupted with the bus: connection cable of the regulator or thermostat loose, cut, or poorly connected.

    Check the connection cable of the regulator or thermostat and its terminals. If the cable is fine, have a technician check it.

Junkers fault codes that require diagnosis

CodeFaultTechnical checks
EAFlame not detected when igniting.Check that the gas valve is open, the gas pressure, and the electrodes with their cable. If everything is fine and the fault code persists, the PCB is suspect: have a technician check it.
F0Internal fault of the PCB.Check the electrical contacts and the ignition wires. If the fault code persists, the PCB is suspect: have a technician replace it.
FAThe flame is still detected after the gas disconnection.Check the gas valve, clean the condensate siphon, and inspect the electrodes. If the issue persists, have a technician check it.
E9The temperature limiter of the heat block or exhaust gases has been triggered.Check the service pressure, the operation of the pump and the fuses on the PCB, and bleed the unit. If the fault code returns, have a technician check it.
A8Communication interrupted with the regulator or thermostat bus.Check the connection cable of the regulator or thermostat and its terminals. If the cable is fine, have a technician check it.
CCThe PCB does not detect the outdoor temperature sensor.Check the outdoor sensor and its cable for any interruptions. It only appears with the outdoor sensor installed.
d3The external controller has been activated: bridge 8-9 or bridge PR-P0 is missing, or the limiter TB1 is open.Check the terminal strip, the bridges 8-9 and PR-P0, and the limiter TB1 before suspecting the PCB.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Technical sheet: Junkers

Uniclima internal SKU
PLC231
Brand
Junkers
Type of part
Junkers
Units in stock
1 unit
Status
Refurbished
Warranty
1 year
Shipping
Delivery time shown at checkout
Return
14 days

Part data and available documentation

Contrast the label codes, PCB, and revision with the installed part; they are not necessarily equivalent references.

Stock code
873791898A
Green module label
873792116A
Additional label for the green module
08 15 38 3805
PCB markings
OC-118; 94V-0; H; E122808
Traceability label on the reverse
873791679A0615491552; SV6.0
Identification — Stock code
873791898A
Identification — Label of the separate green module
873792116A
Identification — Additional label of the green module
08 15 38 3805
Identification — PCB Markings
OC-118; 94V-0; H; E122808
Identification — Traceability label on the back
873791679A0615491552; SV6.0
Registered reference
873791898A
Additional markings
Inventory reference with prefix: 873791898A. Separate green module: 873792116A; additional label 08 15 38 3805. PCB markings: OC-118; 94V-0; H; E122808. Traceability label on the back: 873791679A0615491552; SV6.0.
Pending applications to verify
Junkers ZWB30/32 1 A23 — compatibility noted; pending confirmation by variant.
Before purchasing
  • Do not confuse: 873790949A0 — Junkers PCB that is compatible with the ZWB 30/32-1 A23; it is also written as 873790949A (ref. 288.45.0096) — It is a different code from 873791898A. Confirmation registered: 873791898A for that boiler.
  • Do not confuse: 8738725710 — PCB Junkers ZWB 30/36-1 — It is from another model, the ZWB 30/36-1, and another code.
  • Do not confuse: 8 748 300 437 — Control board of the Junkers Cerasmart ZB/ZWB/ZSB series, according to a service manual — It belongs to a different series: the ZWB 30/32-1 A23 does not appear in that table.
  • The unit has several different codes (bag, green module, and reverse). Compare them all with your PCB, not just one.
  • registered for the Junkers ZWB30/32 1 A23. not confirmed independently citing 873791898A: the official parts lists cannot be read and another code (873790949A0) for that boiler.
  • Pending confirmation of registered applications by model, variant, or programming: Junkers ZWB30/32 1 A23.
Frequently Asked Questions

Frequently asked questions: junkers

Where is the code for this PCB and what other markings should I compare?
The main code is 873791898A (bag code). Also compare the marking OC-118 on the printed circuit board, the label of the separate green module (873792116A and 08 15 38 3805), and the traceability label on the back (873791679A0615491552, with SV6.0).
Is it compatible with my Junkers ZWB30/32 1 A23?
The compatibility of this variant is pending confirmation. Registered application: this PCB 873791898A for the Junkers ZWB30/32 1 A23 (Cerapur Excellence Compact, product code 7736503756 on the manufacturer's energy label). Before ordering it, compare 873791898A and the marking OC-118 with those on your PCB.
Is it compatible with another Junkers boiler other than the ZWB30/32 1 A23?
The compatibility of this variant is pending confirmation. We do not have it registered: it is only verified for the ZWB30/32 1 A23. For another model, compare 873791898A and OC-118 with your PCB, or send us a photo of your part's label and the boiler's specification plate through Contact. You can also call 911 17 77 77.
What does each code of the part mean?
873791898A is the bag code, 873792116A and 08 15 38 3805 are the labels of the separate green module, and 873791679A0615491552 (with SV6.0) is the traceability label on the back. OC-118 is a marking on the printed circuit board. PLC231 is the warehouse reference, not a manufacturer code.
Just to confirm: is another PCB code for the ZWB 30/32-1 A23 the same as 873791898A?
They are different codes. For the ZWB 30/32-1 A23, the PCB 873790949A0 (also written as 873790949A, ref. 288.45.0096) is listed. Confirmation registered: the 873791898A for that boiler. Compare the code of your PCB: if it is 873790949A0, that code does not match this part; also compare OC-118 and the label of the green module. Any questions? Send us a photo of its label from Contact.
Who should install this PCB?
A qualified technician. It is a PCB from a gas boiler, so it is not a job to do without training. Before touching it, you must turn off the power and shut off the gas.
Entrega calculada por destino Delivery time shown at checkout
1-year warranty reviewed and tested
14-day return uninstalled parts
Technical support we verify your model
Junkers PCB OC-118 · 873791898A for ZWB30/32 1 A23