Junkers HT II-3 PCB · 8 748 301 333 for ZWC 28/32 1MFA 23
Application for the exact variant pending confirmation. Main PCB Junkers with code 8 748 301 333 and designation HT II-3 CA GA CC. Its ignition, burner modulation, pump, and safety functions require verification for this variant.
- Type of part
- Junkers
- Status
- Refurbished
- internal SKU
- PLC256
- Warranty
- 1 year
Compatible Junkers boilers
Junkers. 0 confirmed compatibilities. There are 3 other models that we are still verifying.
Models pending verification
These models are associated with this reference, but we have not finished verifying them yet, so we do not consider them compatibleIf your boiler is one of them, send us a photo of the part you are going to replace and we will verify it before you purchase.
| Junkers Euromaxx ZWC 24/28 | Junkers | Unconfirmed |
|---|---|---|
| Junkers Euromaxx ZWB 28/32 | Junkers | Unconfirmed |
| Junkers ZWC 28/32 1MFA 23 | Junkers | Unconfirmed |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if it is the part for your boiler
The part reference, model, and equipment revision must be verified against the manufacturer's documentation.
- Look for the code 8 748 301 333 and the designation HT II-3 CA GA CC on your PCB: these are marked on this part.
- Check the rating plate that your boiler is a Junkers ZWC 28/32 1MFA 23, the one you have registered.
- Compare the complete code: the official list gives 8 748 300 533 for the ZWC28/32-1MFA 23 family (by suffix) and 8 748 300 534-C for yours.
- if they match, call us at 911 17 77 77 with your boiler model and we will reserve it for you.
- Any questions? Send us a photo of the label of your PCB and the rating plate of the boiler from Contact.
Symptoms that require diagnosis in the junkers
Common symptoms and faults
- 01
The boiler does not start, it locks out or operates erratically, with F0.
Cause: it is related to a fault of this PCB (F0, internal fault of the printed circuit). The official Junkers manual for Euromaxx (7 181 465 337, series A/K, not the MFA 23) defines F0 as an internal error of the Heatronic and requests to replace the PCB (our translation from German).
- 02
The boiler shuts down or locks out with fault code EA.
Cause: No flame detected: lack of gas, dirty ionization electrode, or poor ionization.
Press reset once if the boiler allows it. If it repeats, have a technician check the gas, the electrode, and its cable.
- 03
The display turns off intermittently or the fault code F0 appears.
Cause: Internal fault of the PCB or loose connections, sometimes due to humidity in the control board enclosure.
Have a technician check the humidity and the connections before replacing the PCB.
- 04
The boiler stops due to overheating and displays fault code E9.
Cause: The safety limiter has been activated: it could be air in the circuit, a blocked pump, or a blown fuse on the PCB.
Bleed the air from the system. If the fault code returns, have a technician check the pump, the fuse, and the sensor.
- 05
The boiler does not ignite and the screen shows EA.
Cause: No flame detected on ignition: there is no ionization current.
Check that the gas valve is open and that there is pressure. If the gas is flowing properly, have a technician check the electrode, its cable, and the PCB.
- 06
The screen shows F0.
Cause: Internal fault of the PCB or its circuit.
Check the contacts, plugs, and ignition and bus cables. If the fault code persists, have a technician replace the PCB.
- 07
The boiler does not receive the commands from the regulator properly and A8 or AC appears.
Cause: Communication interrupted between the bus module, the control unit, and the electronics.
Check the cable between the module and the control board. If the cable is fine, have a technician check the module or the PCB.
- 08
The boiler stops heating and the screen shows E9.
Cause: The safety limiter (STB) has been activated due to excessive temperature.
Check that the pump is circulating, bleed the system, and check the fuse on the PCB. If the fault code returns, have a technician check it.
- 09
On the screen, CC or E2 appears: the PCB is not reading a sensor correctly.
Cause: External sensor or interrupted flow sensor or short-circuited.
Check the affected sensor and its cable. If the sensor and the cable are fine, have a technician check it.
Junkers fault codes that require diagnosis
| Code | Fault | Technical checks |
|---|---|---|
| EA | There is no ionization current: the boiler does not detect the flame and shuts down or locks out. | Press reset once if the boiler allows it. If it repeats, have a technician check the gas, the ionization electrode, and its cable. If all that is fine, it points to the PCB. |
| E9 | Overheating: the safety limiter has been activated. | Check that there is no air in the system and that the flow sensor is properly connected. If the fault code returns, have a technician check the pump and the fuse on the PCB. |
| F0 | Internal fault of the PCB or its connections. | Check the humidity and the connections of the control board box before replacing it. If the fault code persists, the PCB is the suspected part: have it checked by a technician. |
| FA | It continues to detect flame after closing the gas. | Have a technician check the wiring of the gas valve and the electrode. If the wiring is fine, it points to the PCB. |
| E2 | The heating flow NTC sensor is interrupted or short-circuited. | Check the flow sensor and its cable. If the sensor and the cable are fine, have a technician check the PCB. |
| A7 | The NTC sensor for domestic hot water is interrupted or short-circuited. | Check the domestic hot water sensor and its cable. If the sensor and the cable are fine, have a technician check the PCB. |
| A8 | Communication interrupted between the bus module and the control unit. | Check the cable between the bus module and the control unit or the regulator. If the cable is fine, the module or the PCB may be faulty: have a technician check it. |
| AC | Electrical interruption between the plug module and the Heatronic electronics. | Check the cable between the module and the PCB. If the cable is fine, the fault points to the control board: have a technician check it. |
| CC | The PCB does not detect the outdoor temperature sensor. | Check the outdoor sensor and its cable. It only appears when there is an outdoor sensor or bus regulator installed. |
| d3 | Bornes 8-9 open: the bridge or the thermostat connector is missing. | Check the terminal strip 8-9 and the jumper before suspecting the PCB. |
| AA | Excessive temperature difference between the heating supply and the domestic hot water. | Check the heating and domestic hot water sensors and if there is scale in the heat exchanger. If the sensors are fine, have a technician check it. |
| b1 | Encoder connector on the PCB poorly mounted or defective. | Check that the encoder connector is properly mounted and measure it. If it is fine and the fault code persists, the PCB is the suspect. |
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Technical sheet: Junkers
- Uniclima internal SKU
- PLC256
- Brand
- Junkers
- Type of part
- Junkers
- Units in stock
- 6 units
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- Delivery time shown at checkout
- Return
- 14 days
Part data and available documentation
Contrast the label codes, PCB, and revision with the installed part; they are not necessarily equivalent references.
- Inventory — Indicated reference
- 8 748 300 534-C
- Inventory — Application indicated in inventory
- ZWC 28/32 1MFA 23 Model 2
- Inventory — Mounted relay
- 12 A / 250 VAC 7 A / 250 VAC
- Inventory — Blue circular condenser
- EPCOS
- Inventory — Blue condenser
- 1 μF / 400 V, partial reading "1U H 400 U7"
- Inventory — Visible terminals
- LS, LR, N, S
- Inventory — Assembled component
- HT II-3 / CA CA CC
- Inventory — Indicated brand
- Junkers
- Identification — Marked designation
- HT II-3 CA GA CC
- Identification — Marked code
- 8 748 301 333
- Identification — Marked code
- HT II-3 CA GA CC
- Inventory data — Indicated reference
- 8 748 300 534-C
- Inventory data — Application indicated in inventory
- ZWC 28/32 1MFA 23
- Inventory data — Application indicated in inventory
- Model 2
- Inventory data — Mounted relay
- 12 A / 250 VAC
- Inventory data — Mounted relay
- 7 A / 250 VAC
- Inventory data — Blue circular condenser
- EPCOS
- Inventory data — Blue condenser
- 1 μF / 400 V, partial reading "1U H 400 U7"
- Inventory data — Visible terminals
- LS, LR, N, S
- Inventory data — Assembled component
- HT II-3 / CA CA CC
- Inventory data — Indicated brand
- Junkers
- Pending applications to verify
- ZWC 28/32 1MFA 23; "Model 2" (compatibility text, unidentified variant) — pending confirmation.
- To confirm: Junkers Euromaxx ZWC 24/28 —, as a family and without suffix
- To confirm: Junkers Euromaxx ZWB 28/32 —, as a family and without suffix.
- Do not confuse: 8 748 300 533 — PCB (Printed circuit) that the official Junkers list (2006/07) assigns to suffixes 2800 and 3589 of the ZWC28/32-1MFA 23 family, by suffix — It differs by one digit from 8 748 300 534-C and is not the 8 748 301 333 marked here: compare the complete code.
- Do not confuse: 8 748 300 506 — General column PCB from the same list, without model suffix — It is not the one assigned to the suffixes 2800 and 3589 of the ZWC28/32-1MFA 23 family.
- The designation appears as "HT II-3 CA GA CC" (marked) and as "HT II-3 / CA CA CC" (mounted component). Compare it with the silkscreen on your PCB.
- connect the 8 748 301 333 with a Junkers/Bosch PCB; the official list gives another code, 8 748 300 533, for the family (by suffix). Code and boiler: registered.
- Pending registered applications to confirm by model, variant, or programming: Junkers ZWC 28/32 1MFA 23.