Junkers Heatronic 3 PCB · 8748300923 for Cerapur Comfort ZWBC 30-2 C 23
Refurbished Junkers Junkers

Junkers Heatronic 3 PCB · 8748300923 for Cerapur Comfort ZWBC 30-2 C 23

It is the main control board: it manages ignition, fan, pump, modulation, and safety features. It is suspected in case of internal faults (F0), data errors (b2), or communication errors (A8), after verifying sensors, wiring, and the coded connector.

Type of part
Junkers
Catalogue reference
8748300923
Warranty
1 year
VAT included Stock · 1 unit
Compatibility

Junkers boilers compatible with reference 8748300923

Junkers with reference 8748300923. Five confirmed compatibilities: Junkers Cerapur Comfort ZWBC 30-2 C 23 and Junkers Cerapur Comfort ZWBC 25-2 C 23. There are three other models that we are still verifying.

Proven compatibility

Boiler modelFamilyVerification
Junkers Cerapur Comfort ZWBC 30-2 C 23JunkersContrasted
Junkers Cerapur Comfort ZWBC 25-2 C 23JunkersContrasted
Junkers Cerapur Comfort ZWBC 25-2 C 31JunkersContrasted
Junkers Cerapur Comfort ZWBC 30-2 C 31JunkersContrasted
Junkers Cerapur Comfort ZWBC25-2C 23S3700JunkersContrasted

Models pending verification

These models are associated with this reference, but we have not finished verifying them yet, so we do not consider them compatibleIf your boiler is one of them, send us a photo of the part you are going to replace and we will verify it before you purchase.

Junkers Cerapur ZWBC 24-2 C 23, 24-2 C 31 and 28-2 C 23JunkersUnconfirmed
Junkers Cerapur ZWBC 28-2 C 31JunkersUnconfirmed
Junkers Cerapur Comfort ZWBC25-2C 31S3700JunkersUnconfirmed

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. 8748300923 is the part for your boiler

The part reference, model, and equipment revision must be verified against the manufacturer's documentation.

  1. Check the label on your boiler for the exact model (for example, ZWBC 30-2 C 23) and compare it with the list of compatible boilers.
  2. With the boiler powered off, open the front panel: the PCB is located behind it, in the control box. The 8748300923 is usually printed on the printed circuit board or on a sticker on the side.
  3. Compare the number and position of relays and connectors with the photos: under the same reference, there are different versions.
  4. If they match, call us at 911 17 77 77 with your boiler model and we will reserve it for you.
Diagnosis and fault codes

Symptoms that require diagnosis in the junkers 8748300923

Common symptoms and faults

  • 01

    The boiler does not ignite or respond to the commands from the front panel.

    Cause: To confirm: it attributes it to the PCB. First, check the fuses: the manual indicates three on the board.

  • 02

    Erratic fault codes on the screen without apparent reason.

    Cause: To confirm: it attributes it to the PCB. Check the sensors, wiring, and coded connector first.

  • 03

    Fault code F0 (internal fault).

    Cause: The official manual instructs to check the ignition contacts and cables, and if necessary, replace the PCB.

  • 04

    The display shows F0 (internal fault).

    Cause: Faulty electrical contacts or ignition cables, or internal fault of the PCB.

    Check the electrical contacts, the ignition cables, and the gas/air ratio. Replace the PCB only if necessary.

  • 05

    The display shows the fault code b2.

    Cause: Fault code of the boiler's PCB.

    Check the coded connector, the sensors, and the wiring first. If the fault persists, the PCB is the suspect.

  • 06

    The display shows A8 (communication interrupted with the BUS).

    Cause: Communication with the BUS has been interrupted. If the BUS checks do not explain it, the cause may be in the PCB.

    Check the BUS wiring and its connections, as well as the coded connector, before replacing the PCB.

  • 07

    The display shows F7: the boiler detects a flame while being off.

    Cause: Electrodes in poor condition, issue in the flue or moisture on the PCB.

    Check the electrodes, the flue, and ensure that the PCB is not damp.

Junkers fault codes that require diagnosis

CodeFaultTechnical checks
F0Internal faultCheck the electrical contacts and the ignition cables, as well as the gas/air ratio. If necessary, replace the PCB.
b2Fault code of the PCBCheck the coded connector, the sensors, and the wiring. If the fault persists, consult a technician: the cause may be in the PCB.
A8Communication interrupted with the BUSCheck the BUS wiring and the coded connector before replacing the PCB.
F7Flame detected with the appliance offCheck the electrodes and the flue, and ensure that the PCB is not wet.
E9Temperature limiter triggeredCheck the service pressure, the temperature limiter, the operation of the pump, and the fuses on the PCB, and bleed the boiler.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Technical sheet: Junkers 8748300923

Catalogue reference
8748300923
Uniclima internal SKU
PECZWBC30X
Brand
Junkers
Type of part
Junkers
Units in stock
1 unit
Status
Refurbished
Warranty
1 year
Shipping
Delivery time shown at checkout
Return
14 days

Part data and available documentation

Contrast the label codes, PCB, and revision with the installed part; they are not necessarily equivalent references.

Type of part
Main PCB / control module
Control system
Heatronic 3
Component manufacturer
Omron
Nominal coil voltage of the relay
24 VDC
Declared functions
Ignition, fan, pump, modulation, and safety features
Relay model mounted
OMRON G5RL-1A-E-HR
Relay contacts
16 A, 250 VAC
Source of additional data
Declared information; auxiliary references and applications without equivalent from the accredited manufacturer.
Inventory — Application indicated in inventory
Compatible with reference: Main PCB Heatronic 3 for the Junkers Cerapur Comfort ZWBC 30-2 C 23. It controls ignition, fan, pump, modulation, and safety features. This refurbished unit replaces the original when there are internal faults (F0), data errors (b2), or communication issues (A8), after verifying sensors, wiring, and the coded connector.
Inventory — Subcomponent
OMRON G5NB-1A-E relays; 24 VDC coil.
Manufacturer information — Fuses
3 on the PCB; spare parts behind the cover · Official manual 6 720 615 759
Pending applications to verify
Junkers Cerapur Comfort ZWBC 30-2 C 23 — mentioned in the current description; pending documentary verification.
Before purchasing
  • The b3 in the official manual is a fault of the differential pressure switch; another website lists it as an error of the electronics data. Follow the manual.
  • In E9, the manual instructs to check the pressure, limiter, pump, and fuses of the PCB.
  • To confirm: Junkers Cerapur ZWBC 24-2 C 23, 24-2 C 31 and 28-2 C 23 — by model: (same); only by family ZWBC24/ZWBC28.
  • To confirm: Junkers Cerapur ZWBC 28-2 C 31 — by model:;, only by family ZWBC28
  • To confirm: Junkers Cerapur Comfort ZWBC25-2C 31S3700:
  • Do not confuse: 7 716 010 270 — Number that some provide along with the model ZWBC 30-2 C 23 (referred to as "Serial Number") — explains what it identifies; the reference of the PCB is 8748300923.
  • The 8748300714 and the version identifiers come from a single one each, without explanation: compare your PCB before ordering.
  • (same in: same catalog, 1 origin) and they join the 8748300923 to the ZWBC 30-2 C 23. It is registered as new and as original; they have it refurbished and that is what matters.
Frequently Asked Questions

Frequently asked questions: junkers 8748300923

How do I identify the Junkers Heatronic 3 8748300923 PCB?
Look for the 8748300923 printed on the PCB or on a sticker on the side. Also, compare the number and position of relays and connectors with the photos.
Is it compatible with my Junkers Cerapur Comfort ZWBC 30-2 C 23?
Yes: Confirmed: for that boiler. They also connect the 8748300923 to the ZWBC 30-2 C 23, and the official manual lists the Heatronic 3 as the control board for the Cerapur Comfort.
Is it compatible with other Cerapur Comfort models, such as the ZWBC 25-2 C or the 30-2 C 31?
Registered application for the ZWBC 25-2 C 23, the 25-2 C 31, the 30-2 C 31, and the ZWBC25-2C 23S3700. For the 24-2 and the 28-2, and they name them model by model and only by family (ZWBC24/28): compare the 8748300923 from your PCB or send us a photo of the label and the boiler via Contact.
What do 8748300923, Heatronic 3, and 7 716 010 270 mean?
8748300923 is the reference for the PCB. Heatronic 3 is the name of the control board for the Cerapur Comfort ZWBC 25-2 C and 30-2 C. The 7 716 010 270 goes along with the model ZWBC 30-2 C 23 in the sheets (it is referred to as "Serial Number"); none explains what it identifies.
Are there different versions with the same reference?
Please note that different versions have been manufactured under the same reference. Group 8638515085 and 8737710302_v01 as versions of the PCB. Compare connectors and relays.
What fault does this PCB indicate?
the mounting before F0 (internal fault), b2 (data error) or A8 (communication), after checking sensors, wiring and coded connector. For F0, the official manual instructs to check ignition contacts and cables before replacing it.
Can I install it myself?
No: it must be done by a technician. Recommend a professional technician with experience. The manufacturer's manual requests to use only original spare parts and to cover the Heatronic unit before working on the boiler, due to the risk of damage from water leakage.
How to identify this PCB?
Compare the silkscreen, the distribution of the connectors, and the exact variant of the circuit with the photographs.
Entrega calculada por destino Delivery time shown at checkout
1-year warranty reviewed and tested
14-day return uninstalled parts
Technical support we verify your model
Junkers Heatronic 3 PCB · 8748300923 for Cerapur Comfort ZWBC 30-2 C 23