PCB Control Saunier Duval Thema C / Themis Ref. 8/050151G
Control PCB for Saunier Duval boilers from the Thema C and Themis families. It has the code 8/050151G printed on it, with an output relay (contacts 10A/240V~ and 5A/250V~, coil 24V) and a protection fuse of 80 mA T. It should be checked or replaced if the fuse blows or the PCB stops functioning. The current catalog lists a different reference (05712600); please verify your part code.
VAT included
Consult via WhatsAppSaunier Duval boilers compatible with reference 05712600
PCB with reference 05712600. Five confirmed compatibilities: Themis 23 and Themis AS23.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Saunier Duval Themis 23 | Themis | Contrasted |
| Saunier Duval Themis AS23 | Themis | Contrasted |
| Saunier Duval Themis 23V | Themis | Contrasted |
| Saunier Duval Themis C23 | Themis | Contrasted |
| Saunier Duval Themis C23V | Themis | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if the ref. 05712600 is the part for your boiler
What determines it is not the boiler model, but the reference printed on the part you already have installed.
- Find the reference printed on the installed part and check whether it matches the catalogue reference 05712600. If it is not visible, do not identify the part from its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms and faults that the PCB 05712600 resolves.
The PCB controls the ignition, modulation, and safety features of the boiler. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The fuse on the PCB blows as soon as the boiler is connected.
Cause: The fuse activates when there is a short circuit or overload in something that the PCB powers, such as the pump or the gas valve.
Before installing a new fuse, turn off the power and disconnect the pump and the gas valve. Then, check if the fuse holds; this way you can determine if the fault is with the PCB or a component.
- 02
The pump or the burner does not start even though the boiler is requesting heat.
Cause: The output relay of the PCB does not close the contact that provides power to that component.
Measure if there is power at the corresponding output when the boiler demands heat. If there isn't, the fault is in the relay.
- 03
The boiler suddenly stops responding, without any warning or fault code on the screen.
Cause: There is an internal fault in the PCB that interrupts the overall control of the equipment.
Check the fuse visually or with a multimeter and verify the 230V supply before considering that the PCB is damaged.
- 04
It works intermittently: sometimes it turns on and sometimes it doesn't, with no clear pattern.
Cause: There may be a worn relay contact or a loose solder joint inside the PCB.
With the boiler unplugged, check that the connectors on the PCB are properly tightened; a loose contact can cause intermittent faults.
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Data sheet for the Saunier Duval 05712600 PCB.
- Catalogue reference
- 05712600
- Brand
- Saunier Duval
- Type of part
- PCBs (control boards)
- Units in stock
- 3 units
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- 1-2 business days
- Return
- 14 days
Data read on the part and in the manufacturer's documentation
What we have not been able to verify does not appear here.
- Supply voltage
- 230 V
- Protection fuse
- 80 mA T
- PCB code
- 8/050151G
- Manufacturing date
- 96/01/09
- Batch
- 9616
- operational amplifier
- LM358N (marked TAI A3C531)
- Potentiometer P1
- Brand TOKA
Manuals and technical documentation
Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.
- Saunier Duval Themis AS23 Manual (PDF)Document © Saunier Duval, provided as a technical reference.